Pfannenberg BR 50-LED 3G/3D Catalog Page

Pfannenberg BR 50-LED 3G/3D Catalog Page

Ex Signaling devices

Signal Tower

BR 50-LED 3G/3D

BR 50 for Ex applications in the categories 3G and 3D for zones 2 and 22.

extremely long service life (> 50,000 hrs)

the light is amplified by the internal prisms of the impact-proof, heat-resistant and dustproof polycarbonate lens and can be easily recognized from all sides

the technically and economically optimum solution for every application

IP 65

 

+ 50 °C

 

 

 

- 20 °C

 

 

Protection Operating system temperature

Electrical data

 

 

BR 50-LED 3G/3D

 

Version

 

1-stage

 

2-stage

3-stage

Colour order

 

red

red / green

 

yellow / green

red / yellow / green

Rated current

 

230 V AC 50/60 Hz

9 mA

16 mA

 

16 mA

24 mA

 

 

 

 

 

 

 

 

24 V AC 50/60 Hz

60 mA

90 mA

 

80 mA

130 mA

consumption

 

 

 

 

 

 

 

 

 

 

24 V DC

50 mA

80 mA

 

70 mA

120 mA

 

 

 

 

 

 

 

 

 

 

 

 

 

230 V AC 50/60 Hz

 

 

195 V – 253 V

 

 

 

 

 

 

 

 

Operating range

24 V AC 50/60 Hz

 

 

18 V – 28 V

 

 

 

24 V DC

 

 

18 V – 28 V

 

 

 

 

 

 

 

 

 

Mechanical data

 

BR 50-LED 3G/3D

 

Explosion protection

 

II 3G Ex nA II T5 X - 20 °C ≤ Ta ≤ + 50 °C

 

II 3D tDA22 IP65 T85°C X - 20 °C ≤ Ta ≤ + 50 °C

 

 

 

Category (area of use)

 

3G (Zone 2)

 

3D (Zone 22)

 

 

 

Testing body

 

Pfannenberg

 

 

 

 

Temperature class T

 

T5

 

 

 

 

 

 

 

X: according to the requirements of prDIN EN 60 079-0, DIN EN 61241-0 (2007) and DIN EN 61241-1 (2005),

Special conditions

 

the equipment is suitable for applications with a low degree of mechanical danger.

 

It must therefore be ensured that the flashing light is mounted with sufficient protection against impacts.

 

 

 

 

 

 

A protective cage is not mandatory.

Light source

 

LED

 

 

 

Operating temperature

 

- 20 °C … + 50 °C

 

 

 

Storage temperature

 

- 40 °C … + 70 °C

 

 

 

 

Relative humidity

 

90%

 

 

 

Protection system according to EN 60529

IP 65

 

 

 

 

Duty cycle

 

100%

 

 

 

Service life of light source

> 50,000 h

 

 

 

 

 

 

lens

polycarbonate (PC)

 

 

 

 

Material

housing

acrylonitrile butadiene styrene (ABS)

 

 

 

 

 

 

connector housing

polycarbonate (PC), light grey RAL 7035

 

 

 

 

Mounting

 

arbitrary

Connecting terminals

 

spring-type terminal 0.08 – 2.5 mm2

Cable entry

 

M20 bottom side

 

 

 

 

 

 

ELECTRO-TECHNOLOGY FOR INDUSTRY

 

 

 

Dimensions

Connection diagram

 

<![if ! IE]>

<![endif]>L

<![if ! IE]>

<![endif]>stage 1 stage 2 stage 3

<![if ! IE]>

<![endif]>80

 

M20

82

85

 

L

1-stage

107

 

 

2-stage

170

 

 

3-stage

233

 

 

Mounting holes H 50 mm x W 70 mm Ø 4.2

Ordering details

Article numbers

 

BR 50-LED 3G/3D

Version

 

230 V AC

 

24 V AC/DC

 

 

 

 

1-stage red

220 93 10 1 000

 

220 93 40 1 000

 

 

 

 

 

2-stage

red/green

220 93 10 2 300

 

220 93 40 2 300

 

 

 

 

 

2-stage

yellow/green

220 93 10 2 301

 

220 93 40 2 301

 

 

 

 

 

3-stage

red/yellow/green

220 93 10 3 000

 

220 93 40 3 000

 

 

 

 

 

Manufacturer’s declaration

We hereby declare that the explosion-protected means of alarm with the type designation

BR 50-LED 3G/3D

has been developed and manufactured in accordance with the requirements as per EN 60079-0.

This declaration is based on compliance with the following regulations and standards:

DIN EN 60079-15 Electrical equipment for areas at risk of explosions – type of protection type ‘n’

DIN EN 50281-1-1 Electrical equipment for use in areas with combustible dust

The BR 50-LED 3G/3D signal towers are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU.

<![if ! IE]>

<![endif]>Ex signaling devices

<![if ! IE]>

<![endif]>Visual

210

 

211

 

 

 

Loading...