Slim yet perceptible design
54 mm diameter complements industrial machinery while offering excellent visibility.
Modular design
Simplifies configuration and assembly of a wide variety of colour and illumination options.
IP 54 / IP 65 enclosure rating
Standard indoor version is easily upgraded for use in outdoor applications and washdown requirements with optional o-rings.
Simple custom configurations
Up to 5 modules can be stacked with 6 different lens colours. Configuration can be changed to suit new requirements.
Stable structure
Mechanical and electronic components are uncoupled, resulting in a more stable structure that is less sensitive to vibration.
Versatile mounting options
Tubular stand or bracket with various tube lengths, or direct to enclosure.
Self-monitoring module
Integrated functional fault monitoring with redundant LED array and dry contact relay supports automatic switchover to secondary LEDs and remote fault notification.
AS-I BUS module
Simple integration to the AS-i Interface BUS System for up to 4 stages or 62 master/slave connections.
Ex-ATEX version (option)
Suitable for zones 2 and 22. See page 104.
Further models on request
BR 50 in 115 V AC.
Webcode
#3137
SIGNAL TOWERS
IP 54 |
UL |
+55 °C |
|
–25 °C |
|||
|
|
||
protection |
|
operating |
|
system |
|
temperature |
PRODUCT |
|
|
|
|
|
BR 50 (standard modules) |
|
|||||
DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Modules |
|
|
|
continuous light |
blinking light 1.5 Hz |
flashing light |
sounder |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Segment stages (total) |
|
max. 5 (order and colour can be selected individually) |
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Light source 1 |
|
|
|
bulb BA15d |
LED |
bulb BA15d |
|
LED |
|
|
|
|
Rated |
|
|
|
per stage |
7 W |
depending on |
7 W |
depending on |
15–40 mA |
175 mA |
||
power |
|
per stage if 5 stages |
5 W |
voltage |
5 W |
voltage |
||||||
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Flash energy |
|
|
230 V AC |
|
|
|
|
|
0.6 J |
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
24 V AC/DC |
|
|
|
|
|
24 V: 1 J |
|
|||
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Sound pressure level |
|
|
|
|
|
|
|
85 dB (A) |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Alarm tones |
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
(tone table page 109) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
230 V AC |
35 mA |
15 mA |
35 mA |
|
– |
10.5 mA |
15 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal current |
|
|
operating range |
|
–15 % ... +10 % |
|
|
–10 % ... +15 % |
–15 % ... +10 % |
|||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
24 V DC |
300 mA |
30 mA |
250 mA |
30 mA |
AC/DC: 100 mA |
12 mA |
||||
consumption |
|
|
||||||||||
|
|
|
|
operating range |
–15 % ... +20 % |
10–30 V |
AC: 10–27 V |
–15 % ... +20 % |
||||
|
|
|
|
DC: 10–35 V |
||||||||
|
|
|
|
|
|
|
|
|
|
|
||
Operating |
|
|
bulb |
|
|
–25 °C ... +50 °C |
|
|
–10 °C ... +45 °C |
|||
temperature |
|
|
LED |
|
–30 °C ... + 60 °C |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|||||
Protection system |
|
|
IP 54 |
|
|
IP 43 |
||||||
according to EN 60529 |
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|||||
Service life of light source |
approx. |
approx. |
approx. |
approx. |
light emission still 70 % |
|
||||||
1,500 hrs |
50,000 hrs |
1,500 hrs |
50,000 hrs |
after 8,000,000 flashes |
|
|||||||
|
|
|
|
|
|
|||||||
Material |
|
|
lens |
|
|
polycarbonate (PC), UV resistant |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
base |
|
|
acrylonitrile butadiene styrene (ABS) |
|
||||||
|
|
|
|
|
|
|
||||||
PRODUCT |
|
|
|
|
|
BR 50 (special modules) |
|
|||||
DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Modules |
|
|
|
monitored continuous light |
|
|
BR 50 AS-i Bus slave |
|||||
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
AS-i |
|
AS-i-AB |
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|||
Module types |
|
|
|
2 x 8 LED, monitored continuous light |
|
|
LED, sounder, continuous light, |
|||||
|
|
|
|
|
|
|
|
blinking light |
|
|||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
||||
Segment stages (total) |
|
max. 3 |
|
|
|
max. 4 |
|
max. 3 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
AS-i profile |
|
|
|
|
|
|
|
|
S-8.F.E |
|
S-8.A.E |
|
|
|
|
|
|
|
|
|
|||||
AS-i specification |
|
|
|
|
|
AS-i 3.0 / EN 50295 |
||||||
|
|
|
|
|
|
|
|
|
||||
Max. slave/master |
|
|
|
|
|
31 |
|
62 |
||||
|
|
|
|
|
|
|
|
|
|
|
||
Alarm output |
|
|
|
max. 230 V / 80 mA, RONmax = 35 Ω |
|
|
|
|
|
|||
|
|
|
(closed at error-free operation) |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|||
Rated power |
|
|
|
|
24 V DC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Nominal current consumption |
|
approx. 35 mA |
|
|
<0.25 A |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
||
Operating range |
|
|
|
|
–15 % ... +20 % |
|
|
26.5–31.6 V |
|
|||
|
|
|
|
|
|
|
||||||
Service life of light source |
50,000 hrs @ 24 °C, 40 % R.H. |
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
<![endif]>SIGNAL TOWERS
P R O D U C T S S I G N A L T O W E R S
Configuration alternatives
STAGE 5
Sounder module
STAGE 4
Flashing light module
STAGE 3
Continuous light module with LED
STAGE 2
Blinking light |
Monitored |
module |
module |
STAGE 1
Continuous light |
|
module |
AS-i-module |
MOUNTING VARIANTS
Modular design permits quick and easy configuration and assembly.
ARTICLE NO. |
|
|
BR 50 MODULES |
||
|
|
|
|
|
|
VERSION |
|
|
230 V AC |
|
24 V DC |
|
|
|
|
|
|
Base and end module |
|
BR50-BC |
|
28250010000 |
|
|
|
BR50-CL-CL |
|
28250040010 |
|
|
|
|
|
|
|
|
|
BR50-CL-YE |
|
28250040030 |
|
|
|
|
|
|
|
Continuous light module |
|
BR50-CL-AM |
|
28250040040 |
|
|
|
|
|
|
|
|
BR50-CL-RE |
|
28250040050 |
||
|
|
|
|||
|
|
|
|
|
|
|
|
BR50-CL-GR |
|
28250040060 |
|
|
|
|
|
|
|
|
|
BR50-CL-BL |
|
28250040070 |
|
|
|
BR50-BL-CL |
28250051010 |
|
28250058010 |
|
|
|
|
|
|
|
|
BR50-BL-YE |
28250051030 |
|
28250058030 |
|
|
|
|
|
|
Blinking light module |
|
BR50-BL-AM |
28250051040 |
|
28250058040 |
|
|
|
|
|
|
|
BR50-BL-RE |
28250051050 |
|
28250058050 |
|
|
|
|
|||
|
|
|
|
|
|
|
|
BR50-BL-GR |
28250051060 |
|
28250058060 |
|
|
|
|
|
|
|
|
BR50-BL-BL |
28250051070 |
|
28250058070 |
|
|
BR50-FL-CL |
28250071010 |
|
28250078010 |
|
|
|
|
|
|
|
|
BR50-FL-YE |
28250071030 |
|
28250078030 |
|
|
|
|
|
|
Flashing light module |
|
BR50-FL-AM |
28250071040 |
|
28250078040 |
|
|
|
|
|
|
|
BR50-FL-RE |
28250071050 |
|
28250078050 |
|
|
|
|
|||
|
|
|
|
|
|
|
|
BR50-FL-GR |
28250071060 |
|
28250078060 |
|
|
|
|
|
|
|
|
BR50-FL-BL |
28250071070 |
|
28250078070 |
LED module, monitored |
|
BR50-LED-M-YE |
– |
|
28250068030 |
|
|
|
|
|
|
(top module) |
|
BR50-LED-M-RE |
– |
|
28250068050 |
|
|
|
|||
|
|
|
|
|
|
LED module, monitored |
|
BR50-LED-M-YE |
– |
|
28250368030 |
|
|
|
|
|
|
(bottom module) |
|
BR50-LED-M-RE |
– |
|
28250368050 |
|
|
|
|||
Sounder module |
|
BR50-SM |
28250081000 |
|
28250088000 |
AS-i module |
|
BR50-AS-i |
|
28250148300 |
|
|
|
|
|
|
|
AS-i-AB module |
|
BR50-AS-i-AB |
|
28250178300 |
|
|
100 mm |
BR50-S100 |
|
28250150010 |
|
Mounting stand (stainless steel) |
|
|
|
|
|
250 mm |
BR50-S250 |
|
28250150020 |
||
with plinth |
|
||||
|
|
|
|
|
|
|
400 mm |
BR50-S400 |
|
28250150040 |
|
Tube with thread |
100 mm |
BR50-T100 |
|
28250160010 |
|
|
|
|
|
|
|
|
|
|
|
|
|
and bracket (stainless steel), |
250 mm |
BR50-T250 |
|
28250160020 |
|
excl. seal and cable |
|
|
|
|
|
400 mm |
BR50-T400 |
|
28250160040 |
||
|
|
||||
Wall bracket for mounting stand |
|
BR50-W |
|
28250200000 |
|
Mounting kit |
|
BR50-BG |
|
28250210000 |
|
Module gasket IP 65 |
|
BR50-MG |
|
28250220000 |
|
Tube gasket IP 65 |
|
BR50-TG |
|
28250230000 |
|
Lamp remover |
|
BR50-LS |
|
28250250000 |
|
|
|
|
|
|
|
Filament bulbs or LED lamps for continuous and blinking modules must be ordered separately.
Base and |
Light module |
Light module |
Light module |
Light module |
Light module |
Light module |
AS-i |
Sounder |
end module |
clear |
yellow |
amber |
red |
green |
blue |
module |
module |
|
|
|
|
|
|
|
|
|