15” SIGNATURE SERIES
24” SIGNATURE SERIES
24” C-SERIES
Form No. Z2668
Rev. A 12/08/2020
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
DANGER
DANGER
CAUTION
CAUTION
INTRODUCTION
CONGRATULATIONS
Congratulations on your purchase of a Perlick high quality
residential Beer Dispenser. Perlick has proudly manufactured
beer dispensing systems for over 50 years for bars, restaurants,
stadiums, arenas and large venues around the world. That same
technology is used in each and every residential beer dispenser
we produce, assuring you’ll pour fresh, cold beer as the brewery
intended it to be enjoyed.
All Perlick products are built with commercial grade stainless
steel, providing you with the beauty and durability for a lifetime
of use. This installation guide will show you how to properly
install the dispensing equipment on your Perlick Beer Dispenser.
We dedicate considerable time to ensure that our products
provide the highest level of customer satisfaction. If, however,
service is required, call Perlick at 800.558.5592. For your own
protection, never return merchandise for credit without our
approval.
IMPORTANT!
The installation of the actual beer
dispenser cabinet should happen prior
to installing the dispensing equipment.
Refer to the Installation Manual that
accompanied the Beer Dispenser for
step-by-step installation of the cabinet.
PLEASE NOTE
The following instructions are for both the Draft Arm
(standard tower) and the Adara Signature Beer Tower.
Some photos and drawings may only show the Draft
Arm, but the instructions will also apply to the Adara
Signature Beer Tower unless noted.
We thank you again for selecting a high quality Perlick Beer
Dispenser. Cheers!
Keep CO2 cylinder away from heat.
Rupture disc vents at 122°F
maximum.
Do not drop or throw regulator or
CO2 cylinder.
Allow only properly trained and
experienced personnel to handle
high pressure gas.
Do not apply oil to the regulator!
C
2 | perlick.com/residential
US
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
INSTALLATION OF DISPENSING EQUIPMENT
Open the tapping kit box and become familiar with its
components. The instructions on pages 4 through 10 will
demonstrate how to properly install the tapping equipment on
your new Perlick Beer Dispenser.
Dispensing Head
All hose connections
use worm-drive
hose clamps (view
enlarged to verify)
Keg
Apply silicone to
bottom ange
Flange Sleeve
Beer Connection
Faucet Lead
Air Distributor
Keg Coupler
NOTE: Image does not accurately reect positions of the dierent
elements within the unit. Positions and hose lengths shown are to
clearly illustrate proper connection methods only.
Distributor is only on
multiple keg units,
each keg is connected
to a valve on the air
distributor. Single keg
is connected directly to
the regulator.
Perlick customer service (800)558-5592 | 3
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
INSTALLATION OF DISPENSING EQUIPMENT
Open the tapping kit box and become familiar with its
components. If the dispensing head is going to be mounted on
a counter top directly above the refrigerated cabinet, have the
counter top pre-drilled using the supplied template on page 11.
Make sure that the access hole in the refrigerated cabinet is in
line with the counter top holes. Remove any obstructions from
the access hole of the refrigerator.
NOTE: Wash tapping devices thoroughly. Flush
beer and faucet lines, as well as the tapping device
(keg coupler) with fresh water.
Scan the QR code with your mobile
device to watch the video instantly.
Follow instructions on pages 4 through 10 to properly install
the tapping equipment on your perlick unit, or watch our Beer
Dispenser Tapping Installation video. Information on how to
Use the following web link to view the video through your
browser window: http://youtu.be/NCKP6x2zZmo
access this video can be found to the right.
IF YOU ARE INSTALLING A DRAFT ARM - SKIP TO PAGE 6. THE FOLLOWING INSTRUCTIONS ARE ADDITIONAL
PREPARATION STEPS FOR THE ADARA DISPENSING HEAD ONLY
1. Mark the air tube for correct length dependent upon your installation scenario. If installing directly on top of the refrigerated
cabinet, make a mark 5 inches from the bottom of the tower (Figure 1). If installing directly on top of a countertop, add the
depth of the countertop to the original 5 inches and mark at that new dimension (Figure 2).
4 | perlick.com/residential
Figure 1.Figure 2.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
Figure 3.
Figure 4.
2. Remove air “T” from end of air tube by loosening fastener holding the two halves together. Remove the air tube from the tower
being careful not to damage the product tube.
3. Cut air tube at mark made in step 1. Re-install air tube into tower and re-install “T” on the end of the air tube so “T” faces the
rear of the tower.
4. Cut product tube 3 inches below the “T” and install included barbed union into product tube and clamp using worm drive
clamp.
Perlick customer service (800)558-5592 | 5
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
1.
Locate the dispensing head , black beer line(s), and hose
clamp(s). Slide one end of each beer line onto the stainless
steel tubes which protrude out the bottom of the dispensing
head and clamp tight.
2.
Remove transit tape with a utility knife around the hole in the
top of the unit from both inside and outside of the cabinet.
Gently punch out foam w/screwdriver and remove. Insert the
beer line(s) through the hole in the counter top. Move head
aside and bead silicone around perimeter of hole, and then
position the head back in place. Fasten using the 4 chrome
screws included with the dispensing head. Wipe o excess
silicone to complete the seal.
3.
Use the 3/8” -thick foam pad included in the tapping kit and
roll into a cylinder. From inside the cabinet, insert the foam
tube up through the hole in the counter top until it is rmly
against the insulation in the dispensing head. Mark, then cut
away any excess foam.
NOTE: If using an Adara tower, foam needs to be installed so that
it is pressed up against the bottom mounting ange of the tower.
6 | perlick.com/residential
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
4.
Install the Air Scoop Kit. Start by removing the upper set of
screws located above the fan on the back wall of the cabinet.
5.
Assemble components from the kit as follows – Insert black
snap bushing into air scoop mounting bracket, then insert
one end of the air snorkel through the snap bushing. A zip
tie can be inserted behind the mounting bracket to keep the
tube in place.
NOTE: For Adara Towers, the air snorkel consists of a 3 inch piece
of black tubing and a 3 inch piece of clear tubing that slides over
each other and then is clamped using included worm drive clamp.
The black tube is inserted per the above instructions and secured
with the included zip tie. The clear tube is installed over the air “T”
from the dispensing head and secured with the included worm
drive clamp. See Figure 4 on page 5 for illustration.
6.
Insert end of the snorkel up into the tower and screw air scoop
mounting bracket into vacated holes above the fan.
Perlick customer service (800)558-5592 | 7
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
7.
If installing a two faucet system, a CO2 manifold will need to
be installed. Locate the red CO2 lines, CO2 manifold and a
#10 x 1/2” sheet metal screw. Slide one end of each hose onto
the barbed ttings on the manifold and clamp. On the left
rear side wall of the beer compartment there is a double row
of screws which run vertically. Remove one of the two top
screws and discard. Insert the sheet metal screw through the
manifold and into the hole vacated previously.
8.
On a single beer system, locate the red CO2 hose. Slide one
end onto the barbed tting of the regulator assembly and
clamp. On systems with two beers, locate the CO2 line that
comes o the backside of the manifold assembly. Slide the
hose onto the barbed tting of the regulator assembly and
clamp. For detailed information on connecting the regulator
to the CO2 cylinder, see page 10.
9.
Locate the low prole keg coupler(s). Slide one of the red
CO2 lines onto the larger barbed tting of coupler and clamp.
Locate one of the black beer lines and slide onto the smaller
barbed tting of the coupler and clamp. Repeat for additional
couplers.
Note: This unit comes standard with
Perlick’s new 304SS Lo-Boy coupler
(40030SSLD)
8 | perlick.com/residential
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
10.
On the right rear sidewall there is a double column of screws.
Remove the left screw. Locate the safety chain and a #10 x
1/2” sheet metal screw from the parts bag. Insert the screw
through the closed end link of the chain and tighten in the
vacant screw hole. The chain can now be used to secure the
tank with “S” hook, preventing damage to the regulator.
11.
CO2 tanks are shipped empty and must be lled prior to
use. Turn the adjusting knob on the regulator counterclockwise until the secondary gauge (top) reads zero.
Make sure that the valve at the bottom of the regulator
where the red hose is connected is in the o position as
shown. Watching the secondary pressure gauge, turn the
regulator adjusting knob clockwise until the pressure is at
15 psig. Adjustments can later be made based on ow rates.
IMPORTANT: All pressure adjustments MUST be made when
the shut-o valve is in the OFF position!
12.
Locate the beer faucet(s) and install onto the dispensing head
shanks. Tighten with supplied spanner wrench. Install black
handle(s) onto faucet(s).
Perlick customer service (800)558-5592 | 9
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
13.
Before tapping, make sure the beer faucet is closed. To tap a
keg, insert the coupler into the neck of the barrel. Turn the
coupler clockwise until it stops (about an 1/8 turn), then push
down on the top of the coupler and again turn clockwise until
it stops. Your barrel is now tapped. Open the CO2 valve on the
regulator as well as the valve on the manifold if used.
CONNECTING THE REGULATOR TO THE CO2 CYLINDER
1. Remove the blue plug from the regulator tting, but do not
remove the carbonic washer.
2. Screw regulator onto gas cylinder valve. Tighten with wrench
until vertically straight. Be sure that the shut-o valve on the
regulator is in the OFF (horizontal) position.
3. Place screw clamp over the end of red line and push onto
regulator tail piece. Tighten clamp with a screwdriver.
4. Turn regulator adjusting screw counterclockwise until it turns
freely.
5. Turn hand valve counter-clockwise on the CO2 cylinder to
the fully open position.
6. Turn regulator adjusting screw clockwise until desired
pressure is reached (approximately 12-15 lbs.) Tighten stop
nut on adjusting screw.
7. Open shut-out valve on bottom of regulator.
8. Dilute a small amount of liquid dishwashing soap and rub
the soapy mixture around connections. If bubbles appear,
tighten connection.
10 | perlick.com/residential
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
INSTALLATION
MOUNTING HOLE TEMPLATE FOR DRAFT ARMS
AND ADARA SIGNATURE TOWERS
NOTE: The hole placement for the Draft Arm and Adara towers
are the same even though the decorative anges are dierent
shapes.
Perlick customer service (800)558-5592 | 11
Perlick Residential is a division of Perlick Corporation