Inside you will find many helpful hints on how to use and maintain your air conditioner
properly. Just a little preventive care on your part can save you a great deal of time
and money over the life of your air conditioner. You'll find many answers to common
problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting
Tips first, you may not need to call for service at all.
!
CAUTION
Contact the authorised service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or infirm persons
without supervision.
Young children should be supervised to ensure that they do not play with the air
conditioner.
If the power cord is to be replaced, replacement work shall be performed by
authorised personnel only.
Installation work must be performed in accordance with the national wiring
standards by authorised personnel only.
NOTE:
All the illustrations in this manual are for explanation purpose only. Your air
conditioner may be slightly different. The actual shape shall prevail.
1
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.
WARNING
!
CAUTION
!
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
Never do this.
!
!
Plug in power plug
properly.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
!
Do not modify power cord
length or share the outlet
with other appliances.
It may cause electric shock or
fire due to heat generation.
!
!
Always ensure effective
earthing.
Incorrect earthing may cause
electric shock.
!
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
It may cause fire and electric
shock.
!
Keep firearms away.
It may cause fire.
Always do this.
WARNING
!
Do not operate or stop the
unit by inserting or pulling
out the power plug.
It may cause electric shock or fire
due to heat generation.
Do not operate with wet
hands or in damp
environment.
It may cause electric shock.
Do not allow water to run
into electric parts.
It may cause failure of machine
or electric shock.
Do not use the socket if it is
loose or damaged.
It may cause fire and electric
shock.
Do not use the power cord
close to heating appliances.
It may cause fire and electric
shock.
Do not damage or use an
unspecified power cord.
It may cause electric shock or fire.
If the power cord is damaged, it
must be replaced by the manufac turer or an authorised service
centre or a similarly qualified per son in order to avoid a hazard.
Do not direct airflow at
room occupants only.
This could damage your health.
!!
Always install circuit
breaker and a dedicated
power circuit.
Incorrect installation may cause
fire and electric shock.
Do not open the unit
during operation.
It may cause electric shock.
Do not use the power cord near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
!
Ventilate room before operating air
conditioner if there is a gas leakage from
another appliance.
It may cause explosion, fire and, burns.
Do not disassemble or modify unit.
It may cause failure and electric shock.
2
When the air filter is to be
removed, do not touch the
metal parts of the unit.
CAUTION
!
Do not clean the air
conditioner with water.
!
Ventilate the room well when
used together with a stove,
etc.
It may cause an injury.
!
When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.
Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.
!
Stop operation and close
the window in storm or
hurricane.
Operation with windows
opened may cause wetting
of indoor and soaking of
household furniture.
Do not place obstacles
around air-inlets or inside
of air-outlet.
Water may enter the unit and
An oxygen shortage may occur.
degrade the insulation. It may
cause an electric shock.
Do not put a pet or house
plant where it will be
Do not use for special
purposes.
exposed to direct air flow.
This could injure the pet or
plant.
Do not use this air conditioner to
preserve precision devices, food,
pets, plants, and art objects.
It may cause deterioration of
quality, etc.
!
Hold the plug by the head
of the power plug when
taking it out.
It may cause electric shock
and damage.
!
Ensure that the installation bracket of
the outdoor appliance is not damaged
due to prolonged exposure.
!
Turn off the main power
switch when not using the
unit for a long time.
It may cause failure of product
or fire.
!
Always insert the filters
securely. Clean filter once
every two weeks.
It may cause failure of
appliance or accident.
If bracket is damaged, there
is concern of damage due to
falling of unit.
Do not use strong detergent such as wax or
thinner but use a soft cloth.
Appearance may be
deteriorated due to change
Do not place heavy object on the
power cord and ensure that the cord
is not compressed.
There is danger of fire or
electric shock.
of product color or
scratching of its surface.
!
Use caution when unpacking and
installing. Sharp edges could cause injury.
Operation without filters may
cause failure.
Do not drink water drained
from air conditioner.
It contains contaminants and
could make you sick.
!
If water enters the unit, turn the unit off at the power
outlet and switch off the circuit breaker. Isolate
supply by taking the power-plug out and contact a
qualified service technician.
3
IMPORTANT SAFETY INSTRUCTIONS
NOTE The power supply cord with
this air conditioner contains a current
detection device designed to reduce
the risk of fire.
Please refer to the section Operation
of Current Device for details.
,
,
In the event that the power supply
cord is damaged, it cannot be
repaired-it must be replaced with a
cord from the Product Manufacturer.
Do not, unde r any
circumst anc es, c ut,
remove, or b ypa ss
the ground ing p ron g.
Power supp ly co rd
with 3-pro ng gr oun din g plug
and curren t det ect ion device
WARNING
For your safety
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from the power cord.
WARNING
Electrical Infor mation
Be sure the electrical service is adequate for the model you have
chosen. This information can be found on the serial plate, which
is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize
shock and fire hazards, proper grounding is important. The power
cord is equipped with a three-prong grounding plug for protection
against shock hazards.
Your air conditioner must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or circuit breaker,
have a qualified electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place.
This could result in mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug.
Operation of Cur rent Devic e
The power supply cord contains a current device that senses damage to the power cord. To test your power
supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head.
Plug in &
press RESET
Press the TEST button, you will notice a click as the RESET
button pops out.
3. Press the RESET button, again you will notice a click as the button
engages.
4. The power supply cord is now supplying electricity to the unit.
(On some products this it also indicated by a light on the plug head.)
NOTE: Some plugs have
buttons on the top.
NOTES:
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be
reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the
product manufacturer.
TEST
RESET
4
NORMAL SOUNDS
High P itche d Cha tt er
High e fficie nc y co mp re ssors
may ha ve a h ig h pi tc he d chatter
duri ng t he c oo li ng c ycle.
Soun d of Rush ing Ai r
At the fro nt o f th e un it , you may
hear t he s ou nd o f ru sh ing air
bein g mo ve d by t he f an
Gurg le/Hi ss
Gurg li ng o r hi ss in g noise may
be hea rd d ue t o re fr ig erant
pass in g th ro ug h ev aporato r
duri ng n or ma l op eration.
NOTE:This air conditioner is designed to be operated under condition as follows:
Vibrat ion
Unit m ay v ib ra te a nd m ake noise
beca us e of p oo r wa ll o r window
cons tr uc ti on o r in correct i ns ta ll at ion.
Ping ing or Sw itc hi ng
Drop le ts o f wa te r hi tting con de ns er
duri ng n or ma l op eration may c au se
ping in g or s wi tc hi ng sounds .
Cooling operation
Heating operation
Outdoor temp:
Indoor temp:
Outdoor temp:
Indoor temp:
18-43OC(T1 Environment)
O
17-32 C(T1 Environment)
-5-24OC(T1 Environment)
O
0 -27 C(T1 Environment)
21-52OC(T3 Environment)
O
17-32
C(T3 Environment)
O
-7-24
C(T3 Environment)
0-30OC(T3 Environment)
Note: Performanc e may be r educed outside of these operating t empe ratures.
AIR CONDITIONER FEATURES
ELE C TRONIC CO N TROL OPER AT I NG INSTRU C TIONS
Before you begin, th orou ghly familiarize yourself w ith th e cont rol panel and remote as shown bel ow
and all its function s, the n follow the symbol for the functions y ou des ire. The unit can be controlled
by the unit control alone or w ith th e remote.
UNIT CONTROL
S
II
Ene rg y
Saver
Temp /T ime r
Temp /T ime r
Sle ep
Check
Fil te r
Ene rg y
S
II
Saver
Temp /T ime r
Temp /T ime r
Sle ep
Check
Fil te r
Auto
Coo l
Dry
Mod e
Fan
on
off
Tim er
(Cooling Only Models)
Fan S pe ed
Aut o
Low
Med
Hig h
On/ of f
Auto
Coo l
Dry
Heat
Mod e
Fan
on
off
Fan S pe ed
Tim er
(Electric Heating models)
NOTE:On some models without Clean Air and (or) Follow Me features.
5
Aut o
Low
Med
Hig h
On/ of f
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.