Perfect Aire 4PAC25000, 4PAC18000, 4PAC15000 User Manual

15,100, 18,000 & 25,000 BTU
USER MANUAL
FOR MODELS:
COMFORT...BUILT TO LAST
4PAC15000 4PAC18000 4PAC25000
Before using your window air conditioner, please read this manual carefully and keep it for future reference, along with your receipt.
CONTENTS
SAFETY PRECAUTIONS .................................................................................. 2-3
IMPORTANT SAFETY INSTRUCTIONS...............................................................4
INSTALLATION INSTRUCTIONS ................................................................... 5-13
Window Mounting........................................................................... 7-11
Thru-the-wall Installation
.............................................................. 12-13
NORMAL SOUNDS ............................................................................................14
AIR CONDITIONER FEATURES
.................................................................. 14
-16
CARE AND CLEANING.......................................................................................17
TROUBLESHOOTING TIPS................................................................................18
This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting Tips” section in this manual contains a chart with solutions to the most common problems. Referring to this section may save time and prevent the need for a service call in the event of a problem.
!
CAUTION
● Contact an authorized service technician for repair or maintenance of this unit.
● Contact an installer for installation of this unit if necessary.
The air conditioner is not intended for use by young children without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
● Disabled persons may require assistance with set up.
● If the power cord is to be replaced, replacement work should be performed by authorized
personnel only.
● Installation and repair work must be performed in accordance with the national wiring standards by authorized personnel only.
● Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
● Units with a heating function should be at least 3 1/3 ft (1 meter) away from any combustible/
flammable materials.
NOTE: All the illustrations in this manual are for explanation purposes only. Unit purchased may be slightly different.
The design and specifications are subject to change without prior notice for product
improvement. Contact Consumer Services at 877-365-6274 for details.
1
SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
! !
!
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Meanings of symbols used in this manual are as shown below.
!
!
!
!
Plug in power plug properly.
Failure to do so may cause
electric shock or fire due to
excess heat generation
Do not modify power cord length or share the outlet with other appliances.
Doing so may cause electric
!
shock or fire due to heat
generation.
Always ensure effective grounding.
Never do this.
Always do this.
! !
Do not operate or stop the unit by inserting or pulling out the power plug directly from the wall.
Doing so may cause electric shock or fire due to heat generation.
.
Do not operate with wet hands or in damp environment.
Doing so may cause electric shock.
Do not allow water to run into electric parts.
WARNIN
G
Do not use a damaged power cord.
Doing so may cause electric shock
or fire. If the power cord is
damaged, it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
Do not direct airflow directly at
room occupants.
This could cause health issues.
!!
Always install circuit breaker and a dedicated power circuit.
Incorrect grounding may cause
!
electric shock.
!
Always unplug the unit if strange sounds, smell or smoke comes from the unit.
!
Failure to do so may cause fire
and electric shock.
Do not use firearms near unit.
Doing so may cause fire.
!
!
Ventilate room before operating air conditioner if there is a gas leakage from another appliance such as a stove.
Failure to do so may cause explosion,
fire and burns.
Doing so may cause failure of machine or electric shock.
Do not use the socket if it is loose or damaged.
Doing so may cause fire and electric shock.
Do not use the power cord close to heating appliances.
Doing so may cause fire and electric shock.
Incorrect installation may cause fire
and electric shock.
Do not open the unit during operation.
Doing so may cause electric shock.
Do not disassemble, modify, or drill holes into the air conditioner.
Doing so may cause failure and electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
Doing so may cause an explosion or fire.
2
CAUTION
!
When removing air filter, do not touch metal parts of the unit.
Doing so may cause an injury.
!
Unit and Circuit breaker/fuse must be switched OFF when cleaning.
.
Cleaning unit when power is ON
may cause fire and electric shock
and may cause an injury.
Stop operation and close the window in severe storms or hurricanes.
Operation with windows open may cause moisture to enter the room.
Do not place obstacles around air-inlets or inside of air-outlet.
Obstacles may cause appliance failure or accident.
Do not clean with water.
Water may enter the unit and degrade the insulation causing an
electric shock.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
!! !
Hold the plug by the head of the power plug when taking it out.
Failure to do so may cause electric
shock and damage.
!
Periodically check installation bracket for damage.
.
Prolonged exposure to outdoor elements may cause damage to
installation bracket causing unit to
fall.
!
Ensure proper ventilation especially in rooms with a stove or other appliances.
Failure to do so may result in an oxygen shortage.
!
Use only as intended.
This unit is NOT intended to
preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
If unit will not be used for a long period of time, turn OFF main power switch.
Leaving power on may cause unit failure or fire.
!
Always insert the filters securely. Clean filter AT LEAST once every two weeks.
Operation without secured filters may cause failure. A dirty filter can cause the unit to not run
efficiently.
!
Use only a soft cloth to clean the unit.
Cleaners or detergents may change the color or scratch the surface of the unit.
Do not place heavy objects on the power cord and always ensure that the cord is not compressed.
There is danger of fire or electric shock.
!
Use caution when unpacking and installing.
Sharp edges could cause injury.
Meeting Electrical Requirements
!
WARNING
• Electrical ground is required on this appliance.
• DO NOT ground to a gas line.
• If cold water pipe is interrupted by using plastic, non­metallic gaskets, or other insulating materials. DO NOT use
for grounding.
• Check with a qualified electrician if you are in doubt as to
whether the appliance is properly grounded.
• DO NOT modify power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral, or grounding circuit could result in an electrical shock.
• DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury, or death.
Electrical Shock and Personal Injury Hazard
NEVER drink water drained from air conditioner.
Water from unit contains contaminants and could cause illness.
!
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified serviced technician.
There is danger of electric shock.
Observe all local governing codes and ordinances.
Do not, under any circumstances, remove the power supply cord grounding prong.
NOTE: If codes permit, and a separate grounding wire is used,
it is recommended that a qualified electrician determine that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating materials.
Receptacle Wiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is your responsibility to provide proper and adequate
receptacle wiring, installed by a qualified electrician.
Electrical Requirements
A time delay fuse or time delay circuit breaker is also required. A separate circuit, serving only this appliance, MUST be provided.
3
IMPORTANT SAFETY INSTRUCTIONS
Outdoor temp:
18-43°C/64-109°F
Indoor temp: 0-27°C/32-80°F
NOTE
this air conditioner contains a current detection device designed to reduce the risk of fire.
Please refer to the section "Operation
of Current Device" (below) for details.
In the event that the power supply cord is damaged, it MUST be replaced by
an authorized repairman.
Grounding type wall receptacle
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions,
including the following:
If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
The power supply cord with
DO NOT, under any circumstances, cut, remove, or bypass grounding prong.
Power supply cord with 3-prong grounding plug and current detection device
WARNING!
Prevent Accidents
WARNING!
DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. DO NOT use an extension cord or an adaptor plug. DO NOT remove any prong from the power cord.
WARNING!
Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the
side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If
the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place. This could
result in mechanical damage within the air conditioner.
Do not use an extension cord or an adaptor plug.
Operation of Current Device
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. The RESET button will click as it pops out.
3. Press the RESET button; again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)
NOTES:
Do not use this device to turn the unit on or off. Always make sure the RESET button is pushed in for correct operation.
The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset.
If power supply cord is damaged, it cannot be repaired. Please call Consumer Services at 877-365-6274
to assist with replacement.
For Your Safety
Electrical Information
Plug in & press RESET
TEST
RESET
NOTE: Some plugs have buttons on the top.
NOTE: This air conditioner is designed to be operated under the following conditions:
Cooling Operation
Heating Operation
*Please note that not all units come with a heating element. The “Heating operation” specifications only
apply for units that DO have a heating element.
If the unit is ope rated beyond the conditions specified above, it may cause a fai lure of the unit.
Indoor temp: 17-32°C/62-90°F
Outdoor temp: -5-24°C/23-76°F
(18-52°C/64-125°F for special tropical models)
4
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions.
IMPORTANT- Observe all
governing codes and ordinances.
Note to Installer- Be sure to leave these instructions with the Consumer.
Note to Consumer- Keep these instructions for future reference.
Skill level- Installation of this appliance requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
Required Tools/Hardware
Tools Required (Not Included)
• Pencil
• Level
• Tape measure
Socket wrenches
• Phillips screwdriver
• Adjustable wrench or pliers
• Large flat blade screwdriver
Hardware
(Included - Packed with the unit)
7/16 inch Locking
screw and Flat washer for window panels
3/4 (or 1/2) inch
Long Hex-head Screw
Safety Lock
1/2 inch Long screw and Locknut
2 ea.
4
1
4 ea.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of the air conditioner.
Aluminum house wiring may present special
problems- consult a qualified electrician.
When handling unit, be careful to avoid cuts from
sharp metal edges and aluminum fins on front and rear coils.
3/4 inch Long
Flat Head Bolt
and Locknut
Sill Angle
Bracket
Long hex-head
locking screw for top angle,
side retainer
5 /16 inch Long
Foam insert
Window sash seal foam
R1 Hardware
Weather stripping
(10" x 3/4" x 1/12")
2 ea.
2
10
2
1
2
5
5
Loading...
+ 14 hidden pages