Inductive sensor NCN3-F31-B3B-V1
Dimensions
Model Number
NCN3-F31-B3B-V1
Valve positioner and valve control module
Features
• Direct mounting on standard actuators
• Nominal sensing range 3 mm by V2A
target
• A/B slave with extended addressing
possibility for up to 62 slaves
• Mode of operation, programmable
• Protection degree IP67
• Communication monitoring, turn-off
Connection
B3B-V1
2
I
AS-I
S
1
3
I
II
+
Pinout
1
2
4
3
Accessories
BT65A
Activator for F31 series
BT65X
Activator for F31 series
BT115A
Activator for F31 series
BT115X
Activator for F31 series
BT65B
Activator for F31 series
BT115B
Activator for F31 series
V1-W-2M-PUR
Cable socket, M12, 4-pin, PUR cable
V1-G-2M-PUR
Cable socket, M12, 4-pin, PUR cable
V1-G
Release date: 2011-07-28 17:14 Date of issue: 2011-07-28 226324_eng.xml
4-pin, M12 female field-attachable connector
Subject to modifications without notice
36
7
9
5.4
30
LED
M12 x 1
33.5
5
II I
65
14
25
Technical Data
General specifications
Switching element function programmable
Rated operating distance s
Installation embeddable mountable
Output polarity AS-Interface
Assured operating distance sa0 ... 2.43 mm
Reduction factor r
Reduction factor rCu 0.45
Reduction factor r
Reduction factor r
Slave type A/B slave
AS-Interface specification V3.0
Required master specification ≥ V2.1
Nominal ratings
Operating voltage UB26.5 ... 31.9 V via AS-i bus system
Switching frequency f 0 ... 100 Hz
No-load supply current I
Functional safety related parameters
MTTFd 842 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
LED PWR AS-Interface voltage; LED green
-
LED IN switching state (input); LED yellow
Electrical specifications
Rated operational voltage Ue26.5 ... 31.6 V from AS-Interface
Rated operational current I
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection (system side) connector M12 x 1, 4-pin
Protection degree IP67
Material
Housing
Compliance with standards and directives
Standard conformity
Electromagnetic compatibility
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Products with a maximum operating voltage of ≤36 V do not bear a
0.5
Al
1
303
1. 2
St37
Copyright Pepperl+Fuchs
3 mm
n
≤ 35 mA
0
100 mA
e
PBT
EN 50295:1999-10
EN 60947-5-2:2007
IEC 60947-5-2:2007
CCC marking because they do not require approval.
1

Inductive sensor NCN3-F31-B3B-V1
Programming Instructions
Address 00 preset, alterable via Busmaster or
progrmming units
IO-code D
ID-code A
ID1-code 7
ID2-code E
Data bit
Bit Function
D0 not used
D1 not used
D2 switch output sensor 1
(0=damped; 1=undamped)
D3 switch output sensor 2
(0=damped; 1=undamped)
Parameter bit
Bit Function
P0 Watchdog (0=inactive; 1=active)
P1 switching element function sensor II
0=NO; 1= NC)
P2 switching element function sensor I
0=NO; 1= NC)
P3 not used
1)
Applies to NC function (P2/P3=1; preset), with NO
function (P2/P3=0) reversed characteristics
2)
Default setting: NC
1)
1)
2)
2)
Programming Instructions
Address 00 preset, alterable via Busmaster or
progrmming units
IO-code D
ID-code A
ID1-code 7
ID2-code E
Data bit
Bit Function
D0 not used
D1 not used
D2 switch output sensor 1
(0=damped; 1=undamped)
D3 switch output sensor 2
(0=damped; 1=undamped)
Parameter bit
Bit Function
P0 Watchdog (0=inactive; 1=active)
P1 switching element function sensor II
0=NO; 1= NC)
P2 switching element function sensor I
0=NO; 1= NC)
P3 not used
1)
Applies to NC function (P2/P3=1; preset), with NO
function (P2/P3=0) reversed characteristics
2)
Default setting: NC
1)
1)
2)
2)
Release date: 2011-07-28 17:14 Date of issue: 2011-07-28 226324_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
2