Pepperl Fuchs NCB8-18GM40-N0-OG Data Sheet

Pepperl Fuchs NCB8-18GM40-N0-OG Data Sheet

 

 

 

 

 

 

Inductive sensor

NCB8-18GM40-N0-OG

 

 

 

 

0102

Model Number

NCB8-18GM40-N0-OG

Features

8 mm flush

Usable up to SIL 2 acc. to IEC 61508

Accessories

EXG-18

Quick mounting bracket with dead stop

BF 18

Mounting flange, 18 mm

<![if ! IE]>

<![endif]>Release date: 2017-06-01 08:00 Date of issue: 2017-06-01 244813_eng.xml

Technical Data

General specifications

 

Switching function

 

Output type

sn

Rated operating distance

Installation

sa

Assured operating distance

Actual operating distance

sr

Reduction factor rAl

 

Reduction factor rCu

 

Reduction factor r304

 

Output type

 

Nominal ratings

Uo

Nominal voltage

Switching frequency

f

Hysteresis

H

Reverse polarity protection

 

Short-circuit protection

 

Suitable for 2:1 technology

 

Current consumption

 

Measuring plate not detected

 

Measuring plate detected

 

Switching state indicator

 

Functional safety related parameters

MTTFd

Mission Time (TM)

Diagnostic Coverage (DC)

Ambient conditions

Ambient temperature

Storage temperature

Mechanical specifications

Connection type

Core cross-section

Housing material

Sensing face

Degree of protection

Cable

Bending radius

General information

Use in the hazardous area

Category

Compliance with standards and directives

Standard conformity NAMUR

Electromagnetic compatibility Standards

Approvals and certificates

CCC approval

Dimensions

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Normally closed (NC)

NAMUR

8 mm flush

0 ... 6.48 mm

7.2 ... 8.8 mm typ. 8 mm

0.39

0.36

0.71

2-wire

8.2 V (Ri approx. 1 kΩ)

0 ... 1500 Hz

1 ... 15 typ. 5 %

reverse polarity protected yes

yes , Reverse polarity protection diode not required

≥ 2.2 mA ≤ 1 mA

all direction LED, yellow

2660 a

20 a

0 %

-25 ... 80 °C (-13 ... 176 °F) -40 ... 80 °C (-40 ... 176 °F)

cable PUR (halogen-free) , 2 m blue , Oil resistant , Flame-retardant as per IEC 60332-1

Mud-resistant according to IEC61892-4, appendix D Flexible at temperatures as low as -40 °C

2x 1 mm2 , black

Stainless steel 1.4305 / AISI 303

PBT

IP66 / IP67

> 5 x cable diameter

see instruction manuals 1G; 2G; 3G

EN 60947-5-6:2000

IEC 60947-5-6:1999

NE 21:2007

EN 60947-5-2:2007

IEC 60947-5-2:2007

CCC approval / marking not required for products rated ≤36 V

M18x1

<![if ! IE]>

<![endif]>4

<![if ! IE]>

<![endif]>37

<![if ! IE]>

<![endif]>40

24

LED

1

 

 

 

 

 

 

Inductive sensor

NCB8-18GM40-N0-OG

 

 

 

 

 

 

 

 

Electrical Connection

 

1

L+

2

L-

Equipment protection level Ga

CE marking

 

Effective internal inductivity

Ci

Effective internal inductance

Li

Highest permissible ambient temperature

0102

120 nF ; a cable length of 10 m is considered.

50 H ; a cable length of 10 m is considered.

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.

Equipment protection level Gb

 

 

 

 

CE marking

 

 

0102

 

 

 

 

 

Effective internal inductivity

Ci

120 nF ; a cable length of 10 m is considered.

Effective internal inductance

Li

50 H ; a cable length of 10 m is considered.

Maximum permissible ambient temperature Tamb

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.

 

 

 

 

 

Equipment protection level Gc (ic)

 

 

 

 

CE marking

 

 

 

 

 

 

 

 

 

Effective internal inductivity

Ci

120 nF ; a cable length of 10 m is considered.

Effective internal inductance

Li

50 H ; A cable length of 10 m is considered.

 

 

 

 

 

Equipment protection level Da

 

 

 

 

CE marking

 

 

0102

 

 

 

 

 

Effective internal inductivity

Ci

120 F

 

 

A cable length of 10 m is considered.

Effective internal inductance

Li

50 H

 

 

A cable length of 10 m is considered.

<![if ! IE]>

<![endif]>Release date: 2017-06-01 08:00 Date of issue: 2017-06-01 244813_eng.xml

2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Loading...