Pepperl Fuchs NCB5-18GM70-N0 Data Sheet

Pepperl Fuchs NCB5-18GM70-N0 Data Sheet

 

 

 

 

 

 

 

 

 

 

Inductive sensor

 

 

 

NCB5-18GM70-N0

 

 

 

 

 

 

 

 

 

 

 

 

Technical Data

 

 

 

 

 

 

 

General specifications

 

 

 

 

 

 

 

Switching function

 

Normally closed (NC)

 

 

 

 

 

Output type

 

NAMUR

 

 

 

 

 

Rated operating distance

sn

5 mm

 

 

 

 

 

Installation

 

flush

 

 

 

 

 

Assured operating distance

sa

0 ... 4.05 mm

 

 

 

 

 

Actual operating distance

sr

4.5 ... 5.5 mm typ. 5 mm

 

 

 

 

 

Reduction factor rAl

 

0.35

 

 

 

 

 

Reduction factor rCu

 

0.3

 

 

 

 

 

Reduction factor r304

 

0.74

 

 

 

 

 

Output type

 

2-wire

 

 

 

 

 

Nominal ratings

 

 

 

 

 

 

 

Nominal voltage

Uo

8 V

 

 

 

 

 

Switching frequency

f

0 ... 1000 Hz

 

 

 

 

 

Hysteresis

H

1 ... 15 typ. 5 %

 

 

 

 

 

Reverse polarity protection

 

reverse polarity protected

 

 

 

 

 

Short-circuit protection

 

yes

 

 

 

 

 

Current consumption

 

 

 

 

 

 

 

Measuring plate not detected

 

3 mA

 

 

 

 

 

Measuring plate detected

 

1 mA

 

0102

 

Switching state indicator

 

LED, yellow

 

 

Functional safety related parameters

 

 

 

 

 

 

MTTFd

 

2040 a

 

 

 

 

 

Mission Time (TM)

 

20 a

 

 

Model Number

 

 

 

Diagnostic Coverage (DC)

 

0 %

 

 

 

 

 

Ambient conditions

 

 

 

 

NCB5-18GM70-N0

 

 

 

 

 

Ambient temperature

 

-25 ... 100 °C (-13 ... 212 °F)

 

 

 

 

 

Storage temperature

 

-40 ... 100 °C (-40 ... 212 °F)

 

 

 

 

 

Mechanical specifications

 

 

 

 

Features

 

 

 

 

 

Connection type

 

cable PVC , 2 m

 

 

 

 

 

Core cross-section

 

0.75 mm2

 

 

• 5 mm flush

 

 

 

Housing material

 

Stainless steel 1.4305 / AISI 303

 

 

 

 

 

Sensing face

 

PBT

 

 

Accessories

 

 

 

Degree of protection

 

IP67

 

 

BF 18

 

Cable

 

 

 

 

Mounting flange, 18 mm

 

Bending radius

 

> 10 x cable diameter

 

 

 

General information

 

 

 

 

EXG-18

 

 

 

 

 

Quick mounting bracket with dead stop

 

Use in the hazardous area

 

see instruction manuals

 

 

 

Category

 

1G; 2G; 1D

 

 

 

 

 

 

 

 

 

Compliance with standards and

 

 

 

 

 

 

 

directives

 

 

 

 

 

 

 

Standard conformity

 

 

 

 

 

 

 

NAMUR

 

EN 60947-5-6:2000

 

 

 

 

 

 

 

IEC 60947-5-6:1999

 

 

 

 

Standards

 

EN 60947-5-2:2007

 

 

 

 

 

 

 

IEC 60947-5-2:2007

 

 

 

 

 

Approvals and certificates

 

 

 

 

 

 

 

UL approval

 

cULus Listed, General Purpose

 

 

 

 

 

CSA approval

 

cCSAus Listed, General Purpose

 

 

 

 

 

CCC approval

 

CCC approval / marking not required for products rated 36 V

 

Dimensions

M18x1

 

<![if ! IE]>

<![endif]>4

 

<![if ! IE]>

<![endif]>eng.xml

24

<![if ! IE]>

<![endif]>70

<![if ! IE]>

<![endif]>122667_

 

 

<![if ! IE]>

<![endif]>-02-16

 

LED

<![if ! IE]>

<![endif]>Date of issue: 2018

 

 

<![if ! IE]>

<![endif]>-11-08 17:37

 

 

<![if ! IE]>

<![endif]>Release date: 2016

 

 

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

1

 

 

 

 

 

 

 

Inductive sensor

NCB5-18GM70-N0

 

 

 

 

 

 

 

 

Electrical Connection

 

BN

L+

BU

L-

Equipment protection level Ga

 

 

 

CE marking

 

 

0102

 

 

 

 

ATEX marking

 

¬II 1G Ex ia IIC T6T1 Ga The Ex-related marking can also be printed on the enclosed label.

Standards

 

EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"

 

 

Use is restricted to the following stated conditions

Appropriate type

 

NCB5-18GM...-N0...

Effective internal inductivity

Ci

95 nF ; a cable length of 10 m is considered.

Effective internal inductance

Li

100 H ; a cable length of 10 m is considered.

Ambient temperature

 

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.

 

 

Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already

 

 

been applied to the temperature table for category 1.

 

 

 

 

Equipment protection level Gb

 

 

 

CE marking

 

 

0102

 

 

 

 

ATEX marking

 

¬II 1G Ex ia IIC T6T1 Ga The Ex-related marking can also be printed on the enclosed label.

Standards

 

EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"

 

 

Use is restricted to the following stated conditions

Appropriate type

 

NCB5-18GM...-N0...

Effective internal inductivity

Ci

95 nF ; a cable length of 10 m is considered.

Effective internal inductance

Li

100 H ; a cable length of 10 m is considered.

Maximum permissible ambient temperature Tamb

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.

 

 

 

 

Equipment protection level Da

 

 

 

CE marking

 

 

0102

 

 

 

 

ATEX marking

 

¬II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.

Standards

 

EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"

 

 

Use is restricted to the following stated conditions

Appropriate type

 

NCB5-18GM...-N0...

Effective internal inductivity

Ci

95 nF ; a cable length of 10 m is considered.

Effective internal inductance

Li

100 H ; a cable length of 10 m is considered.

Maximum permissible ambient temperature Tamb

Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the

 

 

surface temperature, and the effective internal reactance values can be found on the EC-type-examination

 

 

certificate.

 

 

The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of

 

 

the two values must be maintained.

<![if ! IE]>

<![endif]>Release date: 2016-11-08 17:37 Date of issue: 2018-02-16 122667_eng.xml

2Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.

Loading...