EPV 6500 vent
Features
• A selection of vents for specific applications
• Intrinsically safe operation
• Continuous flow vents for precise flow rates for dilution
applications
• Continuous flow outputs for dilution, purging, and
pressurization
• Low leakage rate vents for air or inert gas conversation
• High flow rate vents for fast, large enclosure systems
• Universal mounting in any orientation including most of the
unit inside the enclosure
• Maximum enclosure size 12.75 cu.meters (450 cu.ft.)
• ATEX/IECEx, Zone 1/21 certified for "pyb" and "pxb"
• Up to SIL 2 acc. to IEC 61508
Application
The 6500 system consists of the 6500 control unit, EPV-6500
pressure relief and monitoring vent, and a valve for
pressurization, purging, and with some models dilution for
analyzer applications. The EPV-6500 vents are available in
different configurations for specific or general applications.
The housings are the same but the flows and pressures are
different for specific applications. The continuous flow vent
allows for precise flow rate measurements that allows for
dilution applications in gas analyzers that is dealing with any
hazardous gas. Safe flow rates are user-selectable through
the 6500 control unit for safe operation and control of the
6500-MAN-PV (proportional valve). The EPV-6500 vents can
be mounted in any orientation and the body can be mounted
inside the pressurized enclosure with just the vent cap outside
for clean, un-intrusive look. The EPV-6500-SS-* model
includes reference pressure tubing and hardware for internal
mount. The EPV-6500 vent is intrinsically safe when used with
the 6500 control unit. No I.S. barrier is required with the 6500
control unit.
EPV-6500-*-*
2
Connection
2
4
4-PIN
31
1 + (brown)
2 A (white)
3 – (blue)
4 B (black)
Release date 2018-03-22 21:48 Date of issue 2018-03-22 t179721_eng.xml
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
1

Technical data EPV-6500-*-*
General specifications
Series 6500
Number of volume exchanges 5 to 19
Hazardous environment gas, dust, gas and dust
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Electrical specifications
Connection
Signal BUS back to the 6500 control unit
Connection M12 connector, 4-pin, cable length 5 meters (provided)
Cable length max. 60 meters at 50 pf/ft and 0.2 µH/ft
Indicators/settings
LED indicator POWER: green
Pneumatic parameters
Protective gas supply instrument grade air or inert gas
Maximum pressure depends on the integrity of the enclosure (strength)
Safe pressure Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Purge flow rate See graphs
Purge flow and enclosure pressure rate See graphs
Flow rate for leakage compensation EPV-6500....-01:
Breaking pressure EPV-6500-...-01: 2.0 mbar (0.8" wc)
Conformity
Degree of protection EN 60529
Shock resistance EN 60068-2
Ambient conditions
Ambient temperature -20 ... 70 °C (-4 ... 158 °F)
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Relative humidity 5 ... 90 %, non-condensing
Vibration resistance 5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance 30 g, 11 ms, all axes
Mechanical specifications
Degree of protection IP66
Material
Housing EPV-6500-AA...
Spark arrestor 304 (UNS S30400) stainless steel
Installation - any orientation to enclosure
Mass approx. 1.4 kg (3.1 lb)
Dimensions 127 x 146 x 83 mm (5.0" x 5.8" x 3.3")
Mounting 1 ½" NPT knockout (50.8mm (2") hole) with seal nut included
Release date 2018-03-22 21:48 Date of issue 2018-03-22 t179721_eng.xml
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
max. vent pressure: 25'' wc (635 mm wc) (62 mbar / 6200 pa)
vent pressure range: 0 to 9.9" wc (0 to 25 mbar)
Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Readout on display is in increments of 28 l/min (1 scfm).
Minimum and maximum reading depends on type of vent and supply pressure.
EPV-6500-*-07, 08 will readout continuous flow.
Readout on display is in increments of 28 l/min (1 scfm).
Minimum and maximum reading depends on type of vent and supply pressure.
EPV-6500-*-07, 08 will readout continuous flow.
593 l/hr (21 scfh) @ .63mbar (.25"wc)
1640 l/hr (58 scfh) @ 1.9mbar (0.75"wc)
EPV-6500....-03:
395 l/hr (14 scfh) @ .63mbar (.25"wc)
961 l/hr (34 scfh) @ 1.9mbar (0.75"wc)
EPV-6500....-05:
260 l/hr (9.2 scfh) @ .63mbar (.25"wc)
622 l/hr (22 scfh) @ 1.9mbar (0.75"wc)
EPV-6500....-07: n/a
EPV-6500....-08: n/a
EPV-6500-...-03: 3.5 mbar (1.4" wc)
EPV-6500-...-05: 3.8 mbar (1.5" wc)
EPV-6500-...-07: n/a
EPV-6500-...-08: n/a
body: 6000 series aluminum anodized
cap: 5000 series aluminum anodized
EPV-6500-SS...
body: 6000 series Aluminum anodized
cap: 316L stainless steel
- not gravity dependent
- internal and external mounting possible
2