Ultrasonic proximity switch
6GR6222-3RS00-PF |
Compact range M18S, |
|
Connector M12 |
||
|
Frequency |
|
|
|
|
|
Kompaktreihe M18S, |
|
Stecker M12 |
||
|
Frequenz |
|
|
|
|
Size/Bauform |
|
|
: |
cylindrical M18 Shorty/zylindrisch M18 Shorty |
|
|
|
|
|
angled form / Winkel-Bauform |
|
Function/Funktion |
|
|
: |
Diffuse/Taster |
|
Operating distance/Schaltabstand |
|
|
|
|
|
Sensing range/Erfassungsbereich |
|
: |
35 ... 250 mm |
||
Standard target/Normmessplatte |
|
: |
20 x 20 mm |
||
Rated ultrasonic frequency/ |
|
|
: |
400 kHz |
|
Ultraschallnennfrequenz |
|
|
|
|
|
Frequency output/Frequenzausgang |
|
|
|
|
|
Output/Ausgangsart |
|
|
|
pnp |
|
Rated operational current/ |
|
Ie |
|
max. 150 mA |
|
Bemessungsbetriebsstrom |
|
|
|
|
|
Short circuit strength/Kurzschlußfestigkeit |
|
|
built-in/eingebaut |
||
Output frequency/Ausgangsfrequenz |
|
|
|
|
|
Range high/Bereich hoch |
|
|
|
280 ... 2000 Hz |
|
Range low/Bereich niedrig |
|
|
|
140 ... 1000 Hz |
|
Resolution/Auflösung |
|
|
|
0,5 mm |
|
Measuring rate/Meßrate |
|
|
|
10 ms (100 Hz) |
|
Power supply voltage/ |
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
Rated operational voltage/ |
|
Ue |
: |
24 V DC |
|
Bemessungsbetriebsspannung |
|
|
|
|
|
Operating voltage range/ |
|
UB |
: |
20 ... 30 V DC |
|
Betriebsspannungsbereich |
|
|
|
|
|
No-load supply current/Leerlaufstrom |
Io |
: |
max. 20 mA |
||
max. ripple content/zul. Restwelligkeit |
|
: |
10% |
|
Subject to modifications without notice |
Release: 08.09.2010 |
Copyright Pepperl+Fuchs |
1
Ultrasonic proximity switch
Teach-in/Lerneingang |
|
|
|
|
|
Function/Funktion |
|
: |
Frequency range /Frequenz Bereich |
||
max. input voltage/max. Eingangsspannung |
|
: |
Operational voltage/Betriebsspannung |
||
max. L-Level (Teach-in active)/ |
|
: |
<0,7 V |
|
|
max. L-Pegel (Teach-in aktiv) |
|
|
|
|
|
min. H-Level (Teach-in inactive)/ |
|
: |
15 V |
|
|
min. H-Level (Teach-in inaktiv) |
|
|
|
|
|
Input resistance (No-load supply current)/ |
|
: |
16 kOhm |
|
|
Eingangswiderstand (Stromsenke) |
|
|
|
|
|
min. Teach-in time/min. Teach-in Zeit |
|
: |
3 sec |
|
|
Synchronization/Synchronisieranschluß |
|
: |
not built-in/nicht eingebaut |
|
|
Times/Zeiten |
|
|
|
|
|
Time delay before availability/ |
tv |
: |
20 ms |
|
|
Bereitschaftsverzug |
|
|
|
|
|
Response time/Ansprechzeit |
|
: |
50 ms |
|
|
Temperatures/Temperaturen |
|
|
|
|
|
Rated temperature/ |
Tu |
: |
25 Cel |
|
|
Bemessungstemperatur |
|
|
|
|
|
Ambient temperature/ |
Ta |
: |
-25 ... +70 Cel |
|
|
zul. Umgebungstemperatur |
|
|
|
|
|
Storage temperature range range/ |
Ts |
: |
-40 ... +85 Cel |
|
|
zul. Lagertemperatur |
|
|
|
|
|
Thermal drift (teach value)/ |
|
|
|
|
|
Temperaturdrift (Toleranzwert) |
|
|
|
|
|
by heating treatment/bei Erwärmung |
|
: |
+ 0,17 % / K |
|
|
by cooling off/bei Abkühlung |
|
: |
- 0,17 % / K |
|
|
Electrical protections/ |
|
|
|
|
|
Elektrische Schutzmaßnahmen, EMV |
|
|
|
|
|
Reverse voltage protection/ |
|
: |
built-in/eingebaut |
|
|
Verpolungsschutz |
|
|
|
|
|
Wire breakage protection/ |
|
: |
built-in/eingebaut |
|
|
Drahtbruchsicherheit |
|
|
|
|
|
Inductive overvoltage/Induktionsschutz |
|
: |
built-in/eingebaut |
|
|
False pulses/Einschaltfehlimpuls |
|
: |
suppressed/unterdrückt |
|
|
IEC 61000-4-2 |
|
|
4 kV |
|
|
IEC 61000-4-3 |
|
|
10 V/m |
|
|
IEC 61000-4-4 |
|
|
2 kV |
|
|
IEC 61000-4-6 |
|
|
10 V/m |
|
|
EN 55011 |
|
|
Class B |
|
|
Mechanical protections/ |
|
|
|
|
|
Mechanische Schutzmaßnahmen |
|
|
|
|
|
Degree of protection/Schutzart |
|
: |
IP 67 |
|
|
Shock/Schockbeanspruchung |
|
: |
30 g; 11 ms duration/Einwirkdauer |
||
Vibration/Schwingbeanspruchung |
|
: |
10 bis 55 Hz, 1 mm amplitude/Amplitude |
||
Max. tightening torque/ |
|
: |
60 Nm |
|
|
max. Anzugsdrehmoment |
|
|
|
|
|
Indicators/Anzeigen |
|
: |
LED (yellow)/LED (gelb): |
|
|
|
|
|
Switching status: |
On: |
LED shines/ |
|
|
|
Schaltzustand: |
Ein: |
LED leuchtet |
|
|
|
Teach-in mode: |
|
LED flashes/ |
|
|
|
Teach-in Modus: LED blinkt |
Subject to modifications without notice |
Release: 08.09.2010 |
Copyright Pepperl+Fuchs |
2