Ultrasonic proximity switch
3RG6123-3BF00-PF |
Compact range M30 K3, |
|
Connector M12 |
|
|
4…20 mA, normally open |
|
Stecker M12 |
|
|
Kompaktreihe M30 K3, |
|
|
|
|
4…20 mA, Schließer |
|
|
|
3RG6123-3BE00-PF |
Compact range M30 K3, |
|
Connector M12 |
|
|
4…20 mA, normally closed |
|
Stecker M12 |
|
|
Kompaktreihe M30 K3, |
|
|
|
|
4…20 mA, Öffner |
|
|
|
Size/Bauform |
|
: |
cylindrical M30/zylindrisch M30 |
|
|
|
||||
|
|
|
swivel sensor/schwenkbarer Sensor |
|||||||
Function/Funktion |
|
: |
Diffuse/Taster |
|
|
|
||||
Operating distance/Schaltabstand |
|
|
|
|
|
|
|
|
|
|
Sensing range/Erfassungsbereich |
|
: |
200 ... 1300 mm |
|
|
|
||||
Focusing range/Einstellbereich |
|
: |
200... 1300 mm |
|
|
|
||||
Adjustment/Einstellung |
|
|
Potentiometer / SONPROG |
|
|
|
||||
Standard target/Normmessplatte |
|
: |
20 x 20 mm |
|
|
|
||||
Repeat accuracy/Wiederholgenauigkeit |
R |
: |
+/- 2 mm |
|
|
|
|
|
|
|
Switching hysteresis/Hysterese |
H |
: |
10 mm |
|
|
|
|
|
|
|
Rated ultrasonic frequency/ |
|
: |
200 kHz |
|
|
|
|
|
|
|
Ultraschallnennfrequenz |
|
|
|
|
|
|
|
|
|
|
Analog output/Analogausgang |
|
|
|
|
|
|
|
|
|
|
Output current/Ausgangsstrom |
|
: |
4 ... 20 mA |
|
|
|
||||
Working resistance/Bürde |
|
: |
0 … 300 Ohm |
|
|
|
||||
Characteristic/Kennlinie |
|
: |
Rising/steigend |
|
|
|
||||
Resolution/Auflösung |
|
: |
12 Bit (4095 steps/Schritte) |
|
|
|
||||
Measuring rate/Meßrate |
|
: |
30 ms (33 Hz) |
|
|
|
||||
Accuracy/Genauigkeit |
|
: |
+/- 1,5 % |
|
|
|
|
|
|
|
Power supply voltage/ |
|
|
|
|
|
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
|
|
|
|
|
Rated operational voltage/ |
Ue |
: |
24 V DC |
|
|
|
|
|
|
|
Bemessungsbetriebsspannung |
|
|
|
|
|
|
|
|
|
|
Operating voltage range/ |
UB |
: |
12 ... 30 V DC incl. ripple content / |
|
|
|
||||
Betriebsspannungsbereich |
|
|
12 ... 30 V DC incl. Restwelligkeit |
|
|
|
||||
by reduction of operating voltage/ |
|
: |
12 V |
< |
operating voltage |
< 20 V |
||||
bei Betriebspannungsreduzierung |
|
|
12 V |
< |
Betriebsspannung |
< 20 V |
||||
Detection/Erfassung |
|
: |
20 % < |
reduced sensitivity |
< 0 % |
|||||
|
|
|
20 % < |
reduzierte Empfindlichkeit |
< 0 % |
|||||
No-load supply current/Leerlaufstrom |
Io |
: |
max. 50 mA |
|
|
|
||||
max. ripple content/zul. Restwelligkeit |
|
: |
10 % |
|
|
|
|
|
|
|
Subject to modifications without notice |
Release: 09.09.2010 |
|
Copyright Pepperl+Fuchs |
|
|
|
|
|
||
|
|
|
|
|
1
Ultrasonic proximity switch
Output/Ausgang |
|
|
|
Output/Ausgangsart |
|
: |
pnp |
Rated operational current/ |
Ie |
: |
max. 300 mA |
Bemessungsbetriebsstrom |
|
|
|
Output voltage drop/Spannungsfall max. |
Ud |
: |
max. 3V (300mA) |
Off-state current/Reststrom |
Ir |
: |
max. 0,01 mA |
Short circuit strength/Kurzschlußfestigkeit |
|
: |
built-in/eingebaut |
Overload withstand capability/ |
|
: |
built-in/eingebaut |
Überlastfestigkeit |
|
|
|
Bidirectional connection „Release“/ |
|
|
|
Bidirektionaler Anschluß „Freigabe“ |
|
|
|
As release input/als Freigabeeingang |
|
|
|
max. input voltage/ |
|
: |
30 V |
max. Eingangsspannung |
|
|
|
max. L-Level (SONAR-BERO inactive)/ |
|
: |
0 ... 3 V |
max. L–Pegel (SONAR-BERO inaktiv) |
|
|
|
min. H-Level (SONAR-BERO active)/ |
|
: |
15 ... 30 V or high-resistance/oder hochohmig |
min. H-Level (SONAR-BERO aktiv) |
|
|
|
Input resistance (current sink)/ |
|
: |
0,9 kOhm |
Eingangswiderstand (Stromsenke) |
|
|
|
min. enable time/min. Freigabezeit |
|
: |
90 ms |
As synchronization connection/ |
|
|
|
als Synchronisieranschluß |
|
|
|
max. quantity of SONAR-BERO run in |
|
: |
10 |
synchronism/ |
|
|
|
max. Anzahl der synchron laufenden |
|
|
|
SONAR-BERO |
|
|
|
Times/Zeiten |
|
|
|
Frequency of operating cycles/ |
f |
: |
4 Hz |
Schaltfrequenz |
|
|
|
Time delay before availability/ |
tv |
: |
280 ms |
Bereitschaftsverzug |
|
|
|
Response time/Ansprechzeit |
|
: |
110 ms |
Temperatures/Temperaturen |
|
|
|
Rated temperature/ |
Tu |
: |
25 Cel |
Bemessungstemperatur |
|
|
|
Ambient temperature/ |
Ta |
: |
-25 ... +70 Cel |
zul. Umgebungstemperatur |
|
|
|
Storage temperature range/ |
Ts |
: |
-40 ... +85 Cel |
zul. Lagertemperatur |
|
|
|
Thermal drift (teach value)/ |
|
|
max. ± 1,5 % |
Temperaturdrift (Toleranzwert) |
|
|
|
Subject to modifications without notice |
Release: 09.09.2010 |
Copyright Pepperl+Fuchs |
2