Pentair VLR 4-120, VLR 4-20A, VLR 8-20 A, VLR 8-40, VLR 16-30/2 User Manual

...
Index
1. GENERAL INFORMATION
1.1 Supplied documents
1.1.1 Manual
1.3 Machine identification data
1.4 EC declaration of conformity
1.5 General information on safety
1.5.1 Personnel qualification
1.5.2 Special compliance
1.6 Conventions
1.6.1 Word conventions
1.6.2 Typographical conventions
1.7 Expected uses
1.7.1 Expected uses
1.7.2 Expected modes of installation
1.8 Non expected uses
1.8.1 Liabilities resulting from non expected uses
1.9 Warranty
1.10 Service
1.11 How to use the supplied documents
2. DESCRIPTION
2.1 Description
2.1.1 Architecture and operating principles
2.1.2 Machine structure
2.2 Technical features
2.2.1 Noise
2.2.2 Liability
page 14
page 16
3. INSTALLATION
3.1 Hoisting
3.1.1 Machine free from any type of packaging
3.1.2 Machine packed in cardboard box
3.1.3 Machine packed in a wooden crate
3.1.4 Machines secured on a supporting surface
3.2 Transport
3.3 Storage
3.3.1 Characteristics of the storage area
3.3.2 Environmental characteristics of the storage area
3.4 Preliminary checks
3.4.1 Check for damages
3.4.2 Damage signalling
3.5 Preparation of the installation area
3.5.1 Characteristics of the installation area
3.6 Installation
3.6.1 Connection to piping
3.6.2 Terminal box position
3.6.3 Connection to the electric system
3.7 Adjustment
3.7.1 Machine motor coupling adjustment
4. USE
4.1 Priming
4.1.1 Machines installed under head
4.1.2 Machines installed above head (suction mode)
4.2 Starting
4.3 Start and stop frequency control
page 17
page 21
5. MAINTENANCE
5.1 Lubrication
5.2 Temporarily quiescing
5.3 Periodical inspection
5.4 Extraordinary maintenance
6. OPERATION TROUBLES
7. DISMANTLING
7.1 Disconnecting the machine
7.2 Residual risks after disconnection
page 22
page 23
page 24
13
1. GENERAL INFORMATION
1.1 Supplied documents
1.1.1 Manual
Data
Instruction manual Issue 1 Version 1105 Code 253P7530
Recipients
This manual is dedicated to the operators charged of the machine management during all the phases of its technical life
Contents
This manual includes the following information:
- Manufacturer declaration
- Information on safety
- Sales information
- Information on documents
- Machine description
- Transport information
- Storage information
- Installation information
- Adjustment information
- Use information
- Maintenance information
- Dismantling information
These pieces of information are subdivided into the following chapters and appendixes of this manual:
Chapter 1 : General information Chapter 2 : Description Chapter 3 : Installation Chapter 4 : Use Chapter 5 : Maintenance Chapter 6 : Operating troubles Chapter 7 : Dismantling Appendix : Product specification
1.2 Information ownership
The information contained in this manual is owned by PENTAIR WATER ITALY Srl The reproduction, also partial, of this manual is forbidden without the express authorisation of PENTAIR WATER ITALY Srl The information contained in this manual only concerns the machine specified in the “Product specification” section. PENTAIR WATER ITALY reserves the right to make to the machines the changes not specified in “Machine identification data” whenever deemed right.
1.3 Machine identification data
Machine acronym
Centrifugal electric pump Vertical multistage with “in line” mouth
cast iron base
VLR
VLRI steel base AISI 304
VLRX steel base AISI 316
Nominal delivery in m3/h Number of stages (= nr. of impellers x 10)
Number of impellers (used when lower than the number of stages only)
Version with oval flanges
Version with round flanges.
VLR VLRI VLRX 4 - 80 / 7 (A) (F)
1.4 EC declaration of conformity
See page 2
1.5 General information on safety
We recommend to carefully following the instructions contained in this manual, paying special attention to notes, attention and danger warnings.
Attention
Danger When carrying out repair or maintenance
Danger
Attention
Danger Before using the motor-pump, check every
Danger When starting the motor-pump (by connect-
The user must always comply with the accident prevention local prescriptions in force in the Country where the product is installed.
operations on the motor-pump, remove the plug from the outlet and/or turn off the switch (if existing) disconnecting in this way the power supply to the motor-pump. This will prevent the accidental starting which may cause damages to people and/or things.
Never carry out maintenance, installation or handling operations on the motor-pump with the electric system live: this may cause serious accidents to people, even their death.
During operation, do not remove or handle the motor-pump.
time that the cable and all the electric devices are efficient, repaired and pro­tected.
ing the plug to the outlet and/or turning off the switch) make sure not to be barefoot and that your hand are not wet.
The non-compliance to the procedures and safety precautions contained in the sup­plied documents causes the exclusion of PENTAIR WATER ITALY from any liability.
14
1.5.1 Personnel qualification
Qualification and protection restrictions foreseen for the operators
RECCOMENDED
OPERATOR QUALIFICATION
Carrier Knowledge and
command of the chapters:
- "General informa­tion"
- "Description"
- "Installation"
Installer Qualification
complying with the provisions of the Country of installa­tion, knowledge and command of the chapters:
- "General informa­tion"
- "Description"
- "Installation"
User Knowledge and
command of the chapters:
- "General informa­tion"
- "Description"
- "Use"
Maintenance man
Demolisher Knowledge and
Danger The machine safely operates when used by
Fitness acknowl­edged by PENTAIR WATER ITALY, knowledge and command of the chapters:
- "General informa­tion "
- "Description"
- "Maintenance"
command of the chapters:
- "General informa­tion"
- "Description"
- "Dismantling"
personnel qualified according to the instructions contained in this manual and on board the machine. All the operations shown by this manual must only be carried out by qualified personnel equipped with the protecting means provided for by this manual
PENTAIR WATER ITALY is not liable in case of accidents deriving from the use of non qualified and non authorised personnel and by the non compliance to the instruc­tions present in this manual an on board the machine.
INDIVIDUAL
PROTECTION
MEANS
Protective shoes and gloves
Protective shoes and gloves
Protective shoes and gloves, high temperature protecting overall and gloves
Protective shoes and gloves
Protective shoes and gloves
1.5.2 Special compliance
The use of personnel having a qualification different from the specified one may involve risks for people and/or the machine.
1.6 Conventions
1.6.1 Word conventions
The manual adopts the following conventions
-
Machine
-
Authorised technician
-
Skilled technician
: motor-pumps specified in the
“Product specification” "
: person authorised by PENTAIR
WATER ITALY to carry out on the machine operations not documented by this manual
: person authorised to carry out on the
machine operations not documented by this manual after contacting PENTAIR WATER ITALY
1.6.2 Typographical conventions
Danger Danger indications show the procedure
whose non or partial compliance may cause physical damages to the operator
Attention
Attention indications show the procedures whose non or partial compliance may cause damages to the machine or to the equipment connected to it
Note indications contain important informa­tion highlighted outside the text to which they refer
1.7 Expected uses
1.7.1 Expected uses
The machine has been designed, manufactured and protected to allow the conveying, circulation and the increase in pressure of the following types of fluids:
- Water having a -15 °C to 120 °C temperature (for temperature lower than 0°C the addition of a fit quantity of ice-preventing agent is expected)
- Water glycol mixtures (or ice-preventing products having chemical physical characteristics similar to glycol) with a glycol percentage up to 50%
- Liquids and waters chemically compatible with the materials that are part of the machine
- Neutral, non explosive fluids having a viscosity similar to water
The machine has been designed, manufactured and protected to allow a fluid delivery depending on the required head (see “Product specification”)
1.7.2 Expected modes of installation
The machine has been designed, manufactured and protected to be installed both:
- Indoor
- Outdoor with a protection from atmospheric agents
The machine has been designed, manufactured and protected to be used under the following atmospheric conditions:
- Temperature range: -15 °C to +40 °C
- Allowed relative humidity range: 30 to 90%
15
The machine has been designed, manufactured and protected to be installed in a vertical position with the motor in the upper part. The machine has been designed, manufactured and protected to be:
- Fixed on foundations having the characteristics shown in the appendix “Product specification” paragraph “Foundations”.
- Connected to pipes able to bear the machine weight.
The machine has been designed, manufactured and protected to be fed by electric power having one of the following characteris­tics:
- 230 V, 50 Hz, single phase
- 230 V, 50 Hz, three-phase
- 400 V, 50 Hz, three-phase
Different voltages and frequencies are available on request.
1.8 Non expected uses
The machine has not been designed, manufactured, nor pro­tected for all the uses not expressly specified in “Expected uses”. In particular, the machine has not been designed, manufactured, nor protected for the conveying, circulation and increase in pressure of the following fluids:
- Explosive
- Corrosive
- Oil-derivatives and mixtures containing oil-derivatives.
- Mixtures containing material or fibres in suspension
- Sea water
For special uses, please contact out technical office
1.8.1 Liabilities resulting from non expected uses
PENTAIR WATER ITALY is not liable for possible damages to people, animals or things resulting from a non-expected use of the machine.
1.9 Warranty
Non authorised installation, adjustment and maintenance operations and/or operations carried out by non qualified personnel imply the termination of the warranty
1.10 Service
1.11 How to use the supplied documents
We recommend the operators to carefully read the supplied documents before carrying out any operation on the machine The supplied documents must be kept for the whole life of the machine so that it can be easily found when necessary. If the machine is sold as second-hand, it must be sold together with the supplied documents.
2. DESCRIPTION
2.1 Description
2.1.1 Architecture and operating principles
VLR motor-pumps are centrifugal, vertical multistage motor­pumps with “in-line” suction inlets and delivery. VLR motor-pumps are directly coupled to an asynchronous single or three-phase motor with closed casing and external ventilation. VLR motor-pumps are not self-priming and need a priming procedure. VLR motor-pumps can be equipped with oval or round flanges.
2.1.2 Machine structure
Components VLR VLR32
Base EN GJL 200 Cast iron EN GJS 500 Cast iron
Headatock EN GJL 200 Cast iron EN GJL 200 Cast iron
Shaft AISI 316 AISI 431
Impellers and choke AISI 304 AISI 304
External cylinder AISI 304 AISI 304
Tie rods Steel zincate AISI 316
Mechanical
seal
O-ring EPDM EPDM
Seals Paper ---
Componenti VLRI VLRX
Base AISI 316 AISI 316
Headatock See note 1 See note 1
Shaft AISI 316 AISI 316
Impellers and choke AISI 304 AISI 316
External cylinder AISI 304 AISI 316
Tie rods AISI 316 AISI 316
Mechanical
seal
O-ring EPDM EPDM
Seals Paper Paper
rotating Tungsten Tungsten
fixer Tungsten Grafite
rotating Tungsten Tungsten
fixer Tungsten Tungsten
NOTA: EN GJL 200 (ex G220) cast iron with internal steel drivehead
2.2 Technical features
Machine size and weights
See "Product specification"
Electrical data
See "Product specification " and identification plate.
Pressure
- maximum operating pressure
Num.
n
o
p
q
2B - 30/2 A ÷ 2B - 150 A 4 - 20 A ÷ 4 - 160 A
8 - 20 A ÷ 8 - 120 A
2B - 180 F ÷ 2B - 160 F
4 - 190 F ÷ 4 - 260 F
8 - 140 F ÷ 8 - 200 F
16 - 30/2 F - 100 F ÷ 16 - 160 F
32 - 1 ÷ 32 - 14
Machine VLR – VLRI - VLRX
16
Loading...
+ 8 hidden pages