wet niche light fixtures 783XXX, 784XXX, 789XXX, and 600XXX.
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This niche - fixture housing must be installed by a licensed or certified electrician in accordance
with the National Electrical Code and all applicable local codes and ordinances. Improper
installation will create an electrical hazard which could result in death or serious injury to pool
users, installers or others due to electrical shock, and may also cause damage to property. Read
and follow the specific instructions below.
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this niche.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 for additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
Rev. D 10-29-071P/N 99791800
DANGER! Risk of Electrical Shock or Electrocution!
This product must be installed by a licensed or certified electrician or a qualified pool serviceman
in accordance with the National Electrical Code and all applicable local codes and ordinances.
Improper installation will create an electrical hazard which could result in death --- or serious injury
to pool users, installers or others due to electrical shock, and may also cause damage to property.
Always disconnect the power to the pool light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury to serviceman, pool users or others due to
electrical shock. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
WARNING — Important Safety Information for Pentair Niche and Light Installation
•
All Niche and Light installations must conform with all codes.
•Under no circumstances replace lights by splicing wire under water or behind niche.
WARNING — RISK OF ELECTRIC SHOCK AND INJURY.
USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW.
Important Safety Information for Fountain Fixture Installations
Swimming Pool or SpaWet-Niche Swimming PoolFixture Housing (Forming Shell) ONLY.
(or Spa) Luminaire (Light)DO NOT USE Fountain Fixture Stand.
FountainWet-Niche SubmersibleFixture Housing (Forming Shell) or
Swimming Pool (or Spa)Fountain Fixture Stand.
Luminaire (Light)
(*) Note: Wet-niche luminaires complying with requirements for both uses may bear both the Listed Wet-Niche Swimming Pool (or Spa)
Luminaire UL Mark and the Listed Wet-Niche Submersible Luminaire UL Mark. A luminaire not bearing the corresponding UL Listing Mark
is not considered by UL to have been produced under UL’s Listing and Follow-Up Service for the associated usage location.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
This document is subject to change without notice.
Trademarks and Disclaimers: Pentair Water Pool and Spa and QuickNiche are registered trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may
be used in this document to refer to either the entities claiming the marks and names of their products. Pentair Water Pool and Spa, Inc. disclaims any proprietary interest in
trademarks and trade names other than its own.
P/N 997918002Rev. D 10-29-07
Section I.General Information
A. Ensure that the electrical system of
your pool conforms with the
following requirements of the
National Electrical Code (NEC),
and all local codes and ordinances.
A licensed or certified electrician
must install the electrical system to
meet or exceed those requirements
before the QuickNiche (fixturehousing) is installed.
B. Some of the NEC requirements
are listed below.
1. The lighting circuit must
have a Ground Fault Circuit
Interrupter (GFCI), and have
an appropriately rated
circuit breaker.
2. The junction box or the low
voltage transformer is located
at least 8 inches above water level, 4 inches above ground level, and at least 48 inches from the edge of the pool,
see Figure 1.
To GFCI, Circuit
Breaker and
power source.
Rigid conduit
Figure 1.
48" min.
4" min.
#8 AWG ground connector
bonded to rebar and all other
metal items within 5 feet of
the pool.
9.75"
8" min. from bottom of
Junction Box or Low Voltage
Transformer to water line.
18" min. from water line
to top of lens.
Pilot screw at 12 o'clock position.
12.50"
3. The light fixture and all metal items within five (5) feet of the pool must be properly electrically bonded.
4. The wet niche must be properly installed so the pilot screw hole is at the 12 o’clock position and that the top edge
of the underwater light’s lens is at least 18 inches below the surface of the water in the pool; see Figure 1.
NOTE
The required orientation of all Pentair lights is with the pilot screw at the 12 o’clock position. This is guaranteed by proper niche installation.
5. The niche is properly electrically bonded and grounded via the NO. 8 AWG ground connector located at the rear
of the niche, see Figure 1.
C. Use only Pentair Water Pool and Spa® lighting fixtures in this niche to ensure proper bonding and grounding connections.
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
For proper bonding and grounding connections, use only Pentair Water Pool and Spa
with this niche-fixture housing. Failure to do so could create an electrical hazard which would result in death or
serious injury to pool users, installers and others.
Section II.QuickNiche Installation Instructions for Vinyl Liner Pools
A. Punch or cut a large hole in the panel (minimum diameter of 10-5/8", maximum diameter of 10-3/4") in the desired
location on the pool wall.
B. For hole placement guide refer to the QuickNiche Template, P/N 630020.
®
Underwater Light Fixtures
C. Trim the hole until the niche fits correctly. The correct position of the niche is with the conduit hub at the 12 o'clock
position.
D. Apply two dabs of DC 732 Clear Silicone, (P/N 630023, included with niche), on back of flange and a single bead
across the threads of the niche housing. See Figure 2.
Rev. D 10-29-073P/N 99791800
Loading...