Pentair QuickNiche Instructions Manual

Page 1
QuickNiche® – Vinyl Liner Niche
Installation Procedures
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
Section I. General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Section II. Vinyl Liner Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Section III. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
A. Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Hole Placement Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See attachment P/N 630020
For use ONLY with Pentair Water Pool and Spa
NOT COMPATIBLE WITH BRASS-CHROME FACE RINGS.
®
wet niche light fixtures 783XXX, 784XXX, 789XXX, and 600XXX.
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This niche - fixture housing must be installed by a licensed or certified electrician in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. Read and follow the specific instructions below.
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this niche. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
Rev. D 10-29-07 1 P/N 99791800
Page 2
DANGER! Risk of Electrical Shock or Electrocution!
This product must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death --- or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
WARNINGImportant Safety Information for Pentair Niche and Light Installation
All Niche and Light installations must conform with all codes.
Under no circumstances replace lights by splicing wire under water or behind niche.
WARNING — RISK OF ELECTRIC SHOCK AND INJURY.
USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW.
Important Safety Information for Fountain Fixture Installations
Location of Pentair Fountain Fixture* Required Installation Method Luminaire Use (P/N 560000 – P/N 560001)
(P/N 560002 – P/N 560003)
Swimming Pool or Spa Wet-Niche Swimming Pool Fixture Housing (Forming Shell) ONLY.
(or Spa) Luminaire (Light) DO NOT USE Fountain Fixture Stand.
Fountain Wet-Niche Submersible Fixture Housing (Forming Shell) or
Swimming Pool (or Spa) Fountain Fixture Stand. Luminaire (Light)
(*) Note: Wet-niche luminaires complying with requirements for both uses may bear both the Listed Wet-Niche Swimming Pool (or Spa) Luminaire UL Mark and the Listed Wet-Niche Submersible Luminaire UL Mark. A luminaire not bearing the corresponding UL Listing Mark is not considered by UL to have been produced under UL’s Listing and Follow-Up Service for the associated usage location.
© 2007 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
This document is subject to change without notice.
Trademarks and Disclaimers: Pentair Water Pool and Spa and QuickNiche are registered trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may
be used in this document to refer to either the entities claiming the marks and names of their products. Pentair Water Pool and Spa, Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
P/N 99791800 2 Rev. D 10-29-07
Page 3
Section I. General Information
A. Ensure that the electrical system of
your pool conforms with the following requirements of the National Electrical Code (NEC), and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the QuickNiche (fixture­housing) is installed.
B. Some of the NEC requirements
are listed below.
1. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an appropriately rated circuit breaker.
2. The junction box or the low voltage transformer is located at least 8 inches above water level, 4 inches above ground level, and at least 48 inches from the edge of the pool, see Figure 1.
To GFCI, Circuit Breaker and
power source.
Rigid conduit
Figure 1.
48" min.
4" min.
#8 AWG ground connector bonded to rebar and all other metal items within 5 feet of the pool.
9.75"
8" min. from bottom of Junction Box or Low Voltage Transformer to water line.
18" min. from water line to top of lens.
Pilot screw at 12 o'clock position.
12.50"
3. The light fixture and all metal items within five (5) feet of the pool must be properly electrically bonded.
4. The wet niche must be properly installed so the pilot screw hole is at the 12 o’clock position and that the top edge of the underwater light’s lens is at least 18 inches below the surface of the water in the pool; see Figure 1.
The required orientation of all Pentair lights is with the pilot screw at the 12 o’clock position. This is guaranteed by proper niche installation.
5. The niche is properly electrically bonded and grounded via the NO. 8 AWG ground connector located at the rear of the niche, see Figure 1.
C. Use only Pentair Water Pool and Spa® lighting fixtures in this niche to ensure proper bonding and grounding connections.
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
For proper bonding and grounding connections, use only Pentair Water Pool and Spa with this niche-fixture housing. Failure to do so could create an electrical hazard which would result in death or serious injury to pool users, installers and others.
Section II. QuickNiche Installation Instructions for Vinyl Liner Pools
A. Punch or cut a large hole in the panel (minimum diameter of 10-5/8", maximum diameter of 10-3/4") in the desired
location on the pool wall.
B. For hole placement guide refer to the QuickNiche Template, P/N 630020.
®
Underwater Light Fixtures
C. Trim the hole until the niche fits correctly. The correct position of the niche is with the conduit hub at the 12 o'clock
position.
D. Apply two dabs of DC 732 Clear Silicone, (P/N 630023, included with niche), on back of flange and a single bead
across the threads of the niche housing. See Figure 2.
Rev. D 10-29-07 3 P/N 99791800
Page 4
E. While holding the niche with the conduit hub at the 12
o-clock position, thread the lock ring (P/N 630016) onto the back of the niche until the ring is hand tight. If needed, use a rubber mallet, to fully tighten the ring, but make sure that the conduit hub remains at the 12 o'clock position.
APPLY TWO DABS OF SILICONE ON BACK FLANGE
AND A SINGLE BEAD ACROSS THE
THREADS OF THE NICHE HOUSING.
The niche is only designed for up to 5/8" thick walls. The thread on the lock ring should engage with the niche body threads at least one full thread.
Silicone
F. Install the vinyl liner in the pool per the vinyl liner instructions
provided by the manufacturer. Fill up the pool until just below the level of the niche in order to stretch the liner.
CAUTION
RISK OF PROPERTY DAMAGE
Over tightening or using a motorized screwdriver on the seal ring screws can over torque the screw threads and damage the niche housing and/or liner seal. The required sealing torque of 18-20 in.-lb. can be achieved by the average person using a #2 Phillips screwdriver.
G. Install the seal ring (P/N 630017) using the screws provided, making sure to locate the bottom catch for the light at
the 6 o’clock position (see Figure 3). Tighten the screws in a cross pattern to approximately 18 inch-pounds. For reference this is about as tight as you can get with a normal #2 Phillips screwdriver. DO NOT TIGHTEN WITH A MOTORIZED SCREWDRIVER.
Figure 2.
H. After all the screws have been tightened, cut out the liner along the inside edges of the seal ring and install the light.
Pool Wall
Locking Rib
Lock Ring
P/N 630016
QuickNiche Housing
Pool Liner
Seal Ring w/Gasket P/N 630017
Bottom Catch
Figure 3.
Vinyl liner installation.
P/N 99791800 4 Rev. D 10-29-07
Page 5
Section III. Technical Data
A. Replacement Parts
Vinyl Liner
Vinyl Liner
Wall
Item P/N Description
1 630021 Screw Kit, QuickNiche, 10 hole
2 630017 Face Ring w/Gasket
3 630025 Gasket
4 990010 Screw, Bonding 10-24 X 7/16 in.
5 630016 Lock Ring
Not Shown
619555 Bonding Lug Kit
630022 Screw, Pilot
630023 Silicone Packet, DC 732 Clear
630046 Repair Kit, QuickNiche
Wall
QuickNiche, (Fixture Housing)
12.25
for Vinyl Liner Installation
Vinyl Liner
Seal ring w/gasket
Vinyl Liner
QuickNiche (fixture housing)
Wall
Top conduit hub
Wall
Lock ring
Req. hole
dia.
10-5/8 in.
minimum
Bonding
screw
SAVE THESE INSTRUCTIONS.
Rev. D 10-29-07 5 P/N 99791800
Page 6
This page is blank.
P/N 99791800 6 Rev. D 10-29-07
Page 7
This page is blank.
Rev. D 10-29-07 7 P/N 99791800
Page 8
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
P/N 99791800 8 Rev. D 10-29-07