3/8" - 16 x 2" LG
2" BUSHING
1" WASHER
2" PVC PIPE
QUICK
FLANGE
2" RUBBER
GASKET/
SLEEVE
HEATER
HEADER
*
QUICK-FLANGE INSTALLATION INSTRUCTION SHEET
Each MiniMax Plus Quick-Flange Accessory Kit contains the following items:
One (1) Quick-Flange unit Two (2) 2 in. Rubber gaskets
Four (4) 3/8 Bolts Four (4) 3/8 in. Washers
Two (2) Plastic Sleeves
Pipe
Plastic Bushing
Gasket/Sleeve
FOR 1½ & 2 in. SCHEDULE 40 PVC PIPE
1. Insert plastic sleeves into the “Quick-Flange”
inlet/outlet openings.
2. Slip the 2 in. rubber gaskets over the plastic sleeves.
3. Bolt the “Quick-Flange” to the header.
NOTE
Tighten the bolts evenly! Do not over tighten!
4. Use plumbers roll or medium grit sand paper and
clean the inlet/outlet openings of the “Quick-Flange”.
Use the same method to clean the 2 in. PVC pipe.
The sand paper will break up any grease or
contaminant that may not be cleaned away with a
primer.
5. Use 711 PVC glue (or equivalent) and follow the
manufacturer’s recommendations. Apply to the inlet
opening of the “Quick-Flange”. Do the same to the
PVC pipe and quickly insert the pipe into the
“Quick-Flange” and twist the pipe a 1/4 turn. Do the
same to the other opening of the “Quick-Flange”.
6. For 1½ in. PVC pipe installations, first glue a
1½ in. X 2 in. sch 40 PVC bushing (not supplied
or shown) to the end of the pipe prior to gluing to
the “Quick-Flange”.
FOR 1½ & 2 in. COPPER PIPE
Gasket
NOTE
You “DO NOT” need the plastic bushings.
1. Insert pipe into the inlet/outlet openings of the
“Quick-Flange”
2. Slip the rubber gaskets over the pipe, using the
supplied 2 in. rubber gasket for 2 in. copper pipe or
the 1½ in. rubber gasket (not supplied, available from
the factory) for the 1½ in. copper pipe.
3. Bolt the “Quick-Flange” to the header.
*
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 W. Los Angeles Ave., Moorpark, CA 93021
• (805) 523-2400
P/N 075282 • Rev. B 7/05