Pentair PROAIR CR23, PROAIR CR230216G Series, PROAIR CR230226G Series Instruction Manual

PROAIR
Air Conditioner
Cr23 Model
INSTRUCTION MANUAL
Rev. F
© 2014 Pentair Equipment Protection 89055884
P/N 10-1008-163
TABLE OF CONTENTS
RECEIVING THE AIR CONDITIONER ...........................................................................................................................................3
HANDLING AND TESTING THE AIR CONDITIONER ...................................................................................................................3
INSTALLATION INSTRUCTIONS ..................................................................................................................................................4
SYSTEM CONTROLS ....................................................................................................................................................................4
Level I Temperature Controller ................................................................................................................................................................. 4
Level II and III Temperature Controller ..................................................................................................................................................... 4
TECHNICAL INFORMATION .........................................................................................................................................................5
DESIGN DATA ............................................................................................................................................................................................. 5
DIMENSION DRAWING .............................................................................................................................................................................. 5
Mounting Gasket Kit .................................................................................................................................................................................. 6
Design Notes ...................................................................................................................................................................................... 6
Mounting Cutout Dimensions .................................................................................................................................................................... 6
Components List ........................................................................................................................................................................................ 7
Optional Parts ............................................................................................................................................................................................ 7
Parts List .................................................................................................................................................................................................... 7
Wire Diagrams and Schematics ................................................................................................................................................................ 8
Wire Diagram, Level I ......................................................................................................................................................................... 8
Wire Diagram, Level I with Electric Heater ....................................................................................................................................... 9
Wire Diagram, Level II and III .......................................................................................................................................................... 10
Wire Diagram, Level II and III with Electric Heater ........................................................................................................................ 12
TEMPERATURE CONTROL ........................................................................................................................................................14
PRINCIPLES OF OPERATION ....................................................................................................................................................14
MAINTENANCE ..........................................................................................................................................................................14
Compressor ............................................................................................................................................................................................. 14
Inlet Air Filter ........................................................................................................................................................................................... 14
How To Remove, Clean or Install a New Inlet Air Filter ......................................................................................................................... 15
Condenser and Evaporator Air Movers ................................................................................................................................................... 15
Refrigerant Loss ...................................................................................................................................................................................... 15
TROUBLE SHOOTING .................................................................................................................................................................16
Basic Air Conditioning Trouble Shooting Check List .............................................................................................................................. 16
Symptoms and Possible Causes: ............................................................................................................................................................ 17
WARRANTY ................................................................................................................................................................................18
RETURN AND REPAIR POLICY ................................................................................................................................................................ 18
LIMITATION OF LIABILITY........................................................................................................................................................................ 19
- 2 -
89055884
RECEIVING THE AIR CONDITIONER
Inspect the air conditioner. Check for concealed damage that may have occurred during shipment. Look for dents, scratches, loose assemblies, evidence of oil, etc. Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -­within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier.
Pentair Equipment Protection cannot accept responsibility for freight damages; however, we will assist you in any way possible.
HANDLING AND TESTING THE AIR CONDITIONER
If the air conditioner has been in a horizontal position, be certain it is placed in an upright, vertical or mounting position for a minimum of five (5) minutes before operating.
CAUTION
Do not attempt to operate the air conditioner while it is horizontal or on its side, back or front. The refrigeration compressor is filled with lubricating oil. This will cause permanent damage to the air conditioner and also voids the warranty.
TEST FOR FUNCTIONALITY BEFORE MOUNTING THE AIR CONDITIONER TO THE ENCLOSURE. Refer to the nameplate for proper electrical current requirements, and then connect the power cord to a properly
grounded power supply. Minimum circuit ampacity should be at least 125% of the amperage shown in the design data section for the appropriate model. No other equipment should be connected to this circuit to prevent overloading.
Operate the air conditioner for five (5) to ten (10) minutes. No excessive noise or vibration should be evident during this run period. The condenser blower (ambient air), the evaporator blower (enclosure air), and the compressor should be running.
Condenser air temperatures should be warmer than normal room temperatures within a few minutes. The compressor is provided with automatic reset thermal overload protection. This thermo-switch is located
and mounted inside the plastic enclosure clipped to the compressor. The switch operates when the compressor overheats due to clogged or dirty inlet air filter or if ambient air temperatures exceed nameplate rating or if enclosure dissipated heat loads exceed the rated capacity of the air conditioner. The thermal overload switch will actuate and stop compressor operation. The blowers will continue to operate and the compressor will restart after it has cooled to within the thermal overload cut-in temperature setting.
89055884
- 3 -
INSTALLATION INSTRUCTIONS
1. Inspect air conditioner and verify functionality before mounting the air conditioner, see HANDLING AND TESTING THE AIR CONDITIONER on page 3.
2. Using the cutout dimensions shown in this manual, prepare the air “IN” and air “OUT” openings, and mounting bolt hole pattern for the enclosure.
3. Using the gasket kit provided, install gaskets to air conditioner. See Mounting Gasket Kit on page 6 for proper location.
4. Mount air conditioner on enclosure using mounting bolts and washers provided to secure unit to enclosure. Allow unit to remain upright for a minimum of five (5) minutes before starting. Caution! Air conditioner must be in upright position during operation.
5. Refer to the top of the nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. Use of an extension cord is not recommended. Electrical circuit should be fused with slow blow or HACR circuit breaker.
6. When the unit is equipped with an automatic temperature controller, the controller is preset at the factory for your convenience and should not require adjustment.
SYSTEM CONTROLS
LEVEL I TEMPERATURE CONTROLLER
The Level I controller is located inside the air conditioner. To adjust, disconnect power to the air conditioner. Open the front panel by loosening the front panel screw. Refer to Figure 2 on page 7 to locate the controller. Turn the controller adjustment screw slot counter-clockwise to increase and clockwise to decrease the temperature set point, see Figure 1. The thermostat cooling setpoint is indicated by the alignment of the adjustment screw slot with the dial decal. After completing adjustment, close the front panel and tighten the front panel screw. Restore power to the air conditioner for operation.
LEVEL II AND III TEMPERATURE CONTROLLER
The Level II and III controller is mounted on the air conditioner front panel and is factory set for standard operation. All operating parameters are programmable for custom applications. Refer to the Level II and III programming and Operating Instruction Manual, 10­1008-161.
Figure 1
- 4 -
89055884
TECHNICAL INFORMATION
DESIGN DATA
Max
Model Voltage Hz Phase
BTU/Hr @
131 F/131 F
Amps @ 131
F/131 F
BTU/Hr @
95 F/95 F
Amps @
95 F/95 F
Amb Temp °F/°C
CR230216GXXX 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26 CR230226GXXX 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26
-XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers.
DIMENSION DRAWING
Shipping
Weight
lb./kg
89055884
NOTE:
1. GASKET KIT FOR MOUNTING TO ENCLOSURE INCLUDED.
2. SERVICE CORD TERMINATED WITH APPROPRIATE PLUG CAP. 6FT LONG STANDARD.
- 5 -
MOUNTING GASKET KIT
DESIGN NOTES
1. Gasket kit included. Apply gasket to rear of air conditioner before mounting on enclosure.
2. Service cord terminated with appropriate plug cap.
3. Millimeter dimensions [ ] are for reference only; do not convert to inch dimensions.
4. Allow at least 4 inch inlet and 6 inch outlet clearance for proper ambient air flow. Allow 20 inch above filter for removal.
Mounting gasket kit part no. 23-2000-00 as applied to rear of CR23.
MOUNTING CUTOUT DIMENSIONS
- 6 -
89055884
Loading...