Pentair INTELLIBRITE 5G Installation And User Manual

INTELLIBRITE® 5G White Pool and Spa LED Light Installation and User’s Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTALLATION AND
INTELLIBRITE
®
5G COLOR LED POOL LIGHT
INTELLIBRITE® 5G Pool Light Installation and User’s Guide
Technical Support: Phone: (800) 831-7133 - Fax: (800) 284-4151
Web sites: www.pentairpool.com and www.staritepool.com:
Contents
IMPORTANT WARNING AND SAFETY INSTRUCTIONS...................................ii
IntelliBrite 5G Pool and Spa Lights Overview .................................................... 1
Operating IntelliBrite Pool lights using a wall switch (12 VAC) ........................... 1
Using an External Transformer for Multiple IntelliBrite 12 VAC Light ..................1
Powering on IntelliBrite 5G Lights .................................................................... 2
Selecting a light show mode or fixed color ........................................................ 2
Replacing the IntelliBrite 5G Pool Light Assembly
(in an existing pool/after Electrical Requirements are met) ............................ 3/4
Installing the IntelliBrite 5G Pool Light Fixture
(new pool construction after Electrical Requirements are met) ...................... 6/7
IntelliBrite 5G Pool Light (12 V) Fuse Har ness Replacement .......................... 9
Replacing the IntelliBrite 5G Pool Light Circuit Board Assembly
(in an existing pool) .......................................................................................... 9
Wide and Narrow Angle Lens Adjustment........................................................17
IntelliBrite 5G Pool Light Replacement Kit Par t Numbers ................................18
Always install a new lens gasket (see part number in this
User’s Guide on page 9 and 19), when ever reassembling the light. Failure to do so may permit water to leak into the assembly which could cause; (a) an electrical hazard resulting in death or serious injury to pool users, installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which likewise could result in serious injury to pool user, installers, or bystanders, or in damage to property.
Before Installing luminaries read the following:
THE INTELLIBRITE 5G LED POOL LIGHT AND SPA LIGHT CANNOT BE USED ON A DIMMER CIRCUIT. USING A DIMMER SWITCH WILL RESULT IN PERMANENT DAMAGE TO THE LIGHT.
P/N 619827 Rev G - 4/2015
FOR 12 VAC LUMINARIES: ALWAYS USE A SEPARATE STEP DOWN
TRANSFORMER TO POWER LUMINARIES. SEE DIAGRAM ON PAGE 7. Note: Connect all three wires to the corresponding circuit wires in the Junction Box (black wire to power, white wire to common, and green wire to ground).
12 VAC LUMINARIES SPECIFICATION: 12 VAC, 50/60 Hz REPLACE ANY CRACKED PROTECTIVE SHIELD (CRACKED LENS) WITH NEW LENS AND GASKET.
i
INTELLIBRITE
®
5G Pool Light Installation and User’s Guide
ii
Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information.
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS LIGHT IS NOT INSTALLED AND USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING POOL LIGHTS.
Before installing this product, read and follow all warning notices
and instructions in this Guide. Failure to follow warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions. Please refer to www. pentairpool.com for more information related to this products.
IMPORTANT NOTICE - Attention Installer: This Installation and User’s
Guide (“Guide”) contains important information about the installation, operation and safe use of this underwater pool light. This Guide should be given to the owner and/or operator of this equipment.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
BEFORE WORKING ON POOL LIGHTS always disconnect power to the pool lights at the circuit breaker from the light before servicing the light. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
This underwater light must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injur y to pool users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
Important Safety Information for Pentair Water Pool and Spa Niche and Light Installation
• AllNicheandLightinstallationsmustconformwithallcodes.Iflocalcodes
mandate a cord seal, use Pentair Water Pool and Spa plastic niches (P/N 79206600 and P/N 79206700) and Cord Seal Kit (P/N 670044).
• Underno circumstances replace lights by splicing wire under water or behind niche.
THE INTELLIBRITE
®
POOL LIGHT REQUIRES HIGH VOLTAGE WHICH CAN
SHOCK, BURN, OR CAUSE DEATH.
READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
INTELLIBRITE® 5G Pool Light Installation and User’s Guide
For countries in compliance with International Electromechnical Commission (IEC) regulatory standards: The light fixture must
be installed by a licensed or certified electrician or a qualified pool service person, in accordance with IEC 364-7-702 and all applicable local codes and ordinance. Improper installation will create an electrical hazard, which could result in death or serious injury to pool user, installer or other due to electrical shock and may also cause damage to the property.
iii
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
RISK OF ELECTRIC SHOCK AND INJURY. USE ONLY THE
(*) Note: Wet-niche luminaires complying with requirements for both uses may bare
both the Listed Wet-Niche Submersible Luminaires UL Mark. A luminaire not bearing the corresponding UL Listing Mark is not considered by UL to have been produced under UL’s Listing and Follow-Up Service for the associated usage location.
CAUTION - The IntelliBrite
®
5G Light fixture must only be used with Pentair Water Pool and Spa fixture housings (niches). If the IntelliBrite light fixture is installed into other niches, the installation will not carry U.L. approval and will void all warranties.
Salt is an inherently corrosive material. While the levels of salt required for proper operation of an electronic chlorine generator are relatively low when compared to sea water and other salt solutions, placing any amount of salt in your pool increases the likelihood of corrosion or other deterioration of pool equipment and any surfaces used in and around your pool. Metal parts and certain natural and man-made surfaces are particularly susceptible to corrosion and deterioration when used in and around salt water pools. Pentair does not represent or otherwise guarantee that the proper use of an electronic chlorine generator will prevent corrosion or other deterioration of pool equipment and any surfaces used in and around your pool. Consult your experienced pool professional, who should be able to advise you on the proper material selection, installation techniques for those materials, and the proper use, care and maintenance of those materials for your specific pool type and location in order to minimize the corrosion and deterioration that is inherent in and around salt water pools.
INSTALLATION METHOD SPECIFIED BELOW.
NOTICE: The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
Location of Pentair Water Pool and Spa Fountain Required Installation Method Luminaire Use Fixture* (P/N 560001 and P/N 560000) Swimming Pool Wet-Niche Swimming Pool Fixture Housing (Forming Shell) ONLY. and Spa (or Spa) Luminaire (Light) DO NOT USE Fountain Fixture Stand.
Fountain Wet-Niche Submersible Luminaire (Light) Fixture Housing (Forming Shell) or swimming Pool (or Spa) Luminair (Light) Fountain Fixture Stand
Luminaires not suitable for direct mounting on normally flammable surfaces (suitable ONLY for mounting on non-combustible surfaces.
Surface Mount
Fixed pool and spa luminaries specification:
12 VAC 50/60 Hz - 120VAC ,50/60 Hz.
INTELLIBRITE
®
5G Pool Light Installation and User’s Guide
IntelliBrite® 5G Pool Light Overview
Operating Lights Using a Wall Switch (12 VAC)
IntellliBrite 5G lights can be manually controlled using a standard wall-mount light switch. Multiple IntelliBrite lights can be connected via a junction box to a single switch so that all lights can be switched on and off together. IntelliBrite lights can also be automatically controlled via Pentair IntelliTouch
®
, EasyTouch® and SunTouch® Control Systems. Note:
Multiple IntelliBrite 5G pool/spa lights can also be controlled using the IntelliBrite Controller, for more information see page 2.
Using an External Transformer for Multiple IntelliBrite 12 VAC Lights
When using multiple IntelliBrite 12 VAC lights on a 300 W att transformer, it is recommended that no more than three IntelliBrite pool lights and one (1) IntelliBrite Spa light be used. It is also recommended not to exceed 100 feet of total cable run between the transformer and light. Note: For long cable lengths, set transformer to 14 VAC (see diagrams below).
300 Watt
Transformer
J Box
12 Gauge
(Minimum)
100 ft.
POOL AND SPA FIXED LUMINARIES: Follow these guidelines when installing, replacing or repairing Pentair Water Pool and Spa pool and spa fixed luminaries:
- REPLACE ANY CRACKED PROTECTIVE SHIELD (CRACKED LENS) WITH NEW LENS AND GASKET. FOR MORE INFORMATION SEE PAGE 11.
- FOR LIGHT OPERATION, ONLY USE A SAFETY ISOLATION TRANSFORMER.
300 Watt
Transformer
J Box
12 Gauge
(minimum)
150 ft. max. for spa light
200 ft. max. for pool light
1
This manual describes how to install the IntelliBrite 5G Color LED Pool Light. The IntelliBrite 5G color LED light provides brilliant vivid multi-colors with spectacular effects for your pool. Choose one of the seven pre-programmed color light shows or select one of the five fixed colors to create virtually endless range of dramatic underwater lighting effects for a spectacular effect in your pool. For more information, see page 2.
INTELLIBRITE® 5G Pool Light Installation and User’s Guide
Powering on IntelliBrite® 5G Color Lights
2
When the IntelliBrite light is powered on, a momentarily white light will illuminate, followed by the previously selected color. Note: If power to the light is off for more than five (5) seconds, the last color show mode or fixed color that was saved will be displayed.
Selecting a light show mode or fixed color
Switch power on to the light. A white light will momentarily illuminate, followed by the pre­viously selected color. To select a color show mode (1-7) or fixed color (8-12), turn the wall switch off/on a specific number of times. Each number (1-12) shown below corresponds to the number of times to power-cycle the switch to activate a color light show or fixed color. For details about saving color effects while in “show” modes, see “Hold” and “Recall” fea­ture on page 4. Example: To select California Sunset Mode; turn the light on, then turn off and on six times. During the off/on switching process, no illumination will occur,
Saving a Color Mode or Fixed Color: When power is switched off to the IntelliBrite color lights, the last color show mode or fixed color will be saved. The next time the light is powered on, the previously saved color show mode or fixed color will be displayed. For example, while in “Party Mode” switch the light off. Wait more than 10 seconds, switch the light back on to resume “Party Mode.”
During the off/on switching process, before the selected color is displayed,
no illumination will occur for a brief second. This operating mode is normal during the switching process. During this period the pool and spa will be dark and precautions should be taken to avoid unforeseen accidents. Failure to observe this warning may result in serious injury or death to pool and spa users.
1 SAm Mode: Cycles through
white, magenta, blue and green colors (emulates the Pentair SAm® color changing light).
2 Party Mode: Rapid color
changing building energy and excitement.
3 Romance Mode: Slow
color transitions creating a mesmerizing and calming effect.
4 Caribbean Mode: Transitions
between a variety of blues and greens.
5 American Mode: Patr iotic
red, white and blue transition.
6 California Sunset Mode:
Dramatic transitions of orange, red and magenta tones.
7 Royal Mode: Richer, deeper
color tones.
8 Blue: Fixed color. 9 Green: Fixed color. 10 Red: Fixed color. 11 White: Fixed color. 12 Magenta: Fixed color. 13 Hold: Save the current color
effect during a color light show.
14 Recall: Activate the last
saved color effect.
Number of times to cycle power (1-5)
Number of times to cycle power (6-14)
Using the IntelliBrite Controller (sold separately, P/N 600054), IntelliBrite 5G color pool Lights can all be synchronized so that individual or multiple IntelliBrite lights all lights can be switched on and off together.
Using an IntelliBrite Color Light Controller
INTELLIBRITE
®
5G Pool Light Installation and User’s Guide
Risk of Electrical Shock or Electrocution!
This underwater light must be installed by a licensed or cer tified
electrician or a qualified pool professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electr ical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to ser viceman, pool users or others due to electrical shock.
Replacing the IntelliBrite® 5G Light Assembly
(in an existing pool)
Verify that the pool and spa meets the requirements of the current National Electrical Code
and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electrical Code which the pool’s electrical system must meet are as follows:
• ThelightingcircuithasaGroundFaultCircuitInterrupter(GFCI)forlinevoltage
models, and has an appropriately rated circuit breaker.
• TheJunctionBox(or,for12 volt models, the low voltage transformer) is located at least eight (8) inches (20.3 cm) above ground level and at least 48 inches (1.219 m) from the edge of the pool; see Figure 1 on page 7.
• Thelightxtureandallmetalitemswithinve(5)feet(1.524m)ofthepoolare
properly electrically bonded.
• Thewetnicheisproperlyinstalledsothatthetopedgeoftheunderwaterlight’s
lens is at least 18 inches below the surface of the water in the pool; see Figure 1 on page 7.
• ThewetnicheisproperlyelectricallybondedandgroundedviatheNo.8AWG
ground connector located at the rear of the niche; see Figure 1 on page 7.
• To be certain that the pool’s electrical system meets all applicable requirements, the electrician should also consult the local building department. Note: Use only Pentair wet niches to insure proper bonding and grounding connections.
3
To select a color light show mode or fixed color mode, rotate the dial so that it points to the desired selection.
Hold and Recall Feature: When IntelliBrite color lights are powered on, the
previously selected color will be displayed, unless the HOLD or RECALL feature was previously enabled. Hold button/LED: Press this button (LED on) to capture and save a color effect while displaying one of the light show modes. When the button is pressed, the LED will be on, indicating that the color effect is captured. Recall Button/LED: Use this button (LED on) to activate the last saved color effect. When the button is pressed, the LED will be on, indicating that the color effect is being displayed.
INTELLIBRITE® 5G Pool Light Installation and User’s Guide
The following removal and installation instructions describe how to remove and install the IntelliBrite pool light assembly. Also use these instructions after
completing the following light replacement procedure:
1. WARNING! Switch off main electrical switch or circuit breaker, and the
switch which operates the IntelliBrite underwater light.
2. To remove light fixture assembly from the pool. Remove the special bronze pilot screw at top of face ring. Remove the IntelliBrite light assembly from the niche and place it on the deck.
3. Cut the cord about 12 inches (30.5 cm) from the back of the light assembly.
4. RemoveJunctionBoxcover,disconnectthelightxturewires,and
pull the cord through the conduit. Tip: Before pulling the cord, tape the new cord to the existing cord, This might make it easier to feed the new cord through the conduit (see following step).
5. Feed the new light fixture cord through the conduit from the niche totheJunctionBox.Note: Depending on the length of the conduit, special tools may be required to pull the cord through the conduit.
6. Leave at least four (4) feet of cord to coil around the light fixture; see Figure 1 on page 6. This four (4) feet (1.2192 m) of cord coiled around the light allows the light to be serviced after the pool is filled with water.
7. CutthecordattheJunctionBox,leavingatleastsize(6)inchesof
cord to make connections.
8. Strip six (6) inches (15.2 cm) of the outer cord jacket from the cord to expose the three insulated conductors. Be careful not to damage
the insulation on the three (3) inner conductors).
Strip a 1/2” of insulation
Failure to bring the pool or spa’s electr ical system up to code requirements before installing the underwater light will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
Replacing the IntelliBrite® 5G Light Assembly
(After Electrical Requirements Are Met)
4