IntelliCenter Control System Wireless Control Panel 1
Charging the IntelliCenter Wireless Control Panel2
Home Screen Battery Icon3
Wireless Control Panel Transceiver Installation 4
IntelliCenter Control System Wireless Controller kit 4
Mounting the Wireless Tr ansceiver 4
Connecting the Transceiver to the IntelliCenter
Control System Load Center 6
Home Screen6
Transceiver Connected to the IntelliCenter
Control System Load Center8
iii-vi
P/N 523213 Rev A 2/2017
IntelliCenter Control System Setup9
Power On the Load Center 9
Setup the Wireless Control Panel9
Wireless Control Panel Firmware Update11
IntelliCenter Control System Menu Structure 12
iii
IntelliCenter Control System Wireless Control Panel Installation Guide
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
READ AND FOLLOW ALL WARNING AND SAFETY INSTRUCTIONS
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT (UNIT) IS NOT
INSTALLED AND USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE
WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. This Guide
provides installation and operation instructions for the product. Consult Pentair
Water Pool and Spa, Inc. (“Pentair”) with any questions regarding this
product.
This product is intended for use with swimming pool applications only.
Most states and local codes regulate the construction, installation, and operation of public pools and spas, and
the construction of residential pools and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult your local building and health codes for more information.
™
This guide provides installation and operation instructions for the IntellliCenter
Panel. Consult Pentair Water Pool and Spa, Inc. with any questions regarding this equipment (see “Customer
Service/Technical Support”, page ii).
Attention Installer: This guide contains important information about the installation, operation and safe usage
of this product. Give this guide to the owner and/or operator of this equipment after installation.
Attention User: This manual contains important information that will help you in operating and maintaining this
filter. Please save it for future reference.
Attention User: This Guide contains important information that will help you in operating and maintaining this
product. Please retain it for future reference. Read the entire Installation Guide and all related warning labels
before installing this product. Read the operating instructions and warnings for all equipment in the pool circulating system before operating. Failure to follow safety warnings and instructions can result in severe injury, death,
or property damage. Call (800) 831-7133 for additional free copies of this Guide or replacement safety labels.
Control System Wireless Control
This product is designed and manufactured for safe and reliable service when installed, operated and
maintained according to the information and installation codes referred to in this Guide.
property. Always disconnect the power to the pool light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury to serviceman, pool users or others due to
electrical shock.
This is a safety alert symbol. When you see this symbol in this manual or on the product, look for
one of the following signal words; DANGER, WARNING, CAUTION and NOTICE and comply with the
information. Be alert to the potential hazard. Ensure to read and comply with all of the warnings and
cautions in this manual.
Risk of Electrical Shock or Electrocution!
- Always disconnect power at the circuit breaker before servicing the load center.
Improper installation can create an electrical shock hazard that can result in death
or serious injury.
This product must be installed by a licensed or certified electrician or a qualified
pool professional in accordance with the current National Electrical Code (NEC),
NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local
installation codes and ordinances must also be adhered to. Improper installation
will create an electrical hazard which could result in death or serious injury to pool
users, installers or others due to electrical shock, and may also cause damage to
iv
IntelliCenter Control System Wireless Control Panel Installation Guide
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
Water temperature in excess of 100° F (37.7° C) may be hazardous to your health.
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above
normal body temperature of 98.6° F (37° C.). Effects of hyperthermia include:
(1) Unawareness of impending danger. (2) Failure to perceive heat. (3) Failure to
recognize the need to leave the spa. (4) Physical inability to exit the spa. (5) Fetal
damage in pregnant women. (6) Unconsciousness resulting in danger of drowning.
The use of alcohol, drugs, or medication can greatly increase the risk of fatal
hyperthermia in hot tubs and spas.
A pool or spa pump must be installed by a qualified pool and spa service professional
in accordance with the current National Electrical Code and all applicable local codes
and ordinances. Improper installation may create an electrical hazard which could
result in death or serious injury to pool users, installers, or others due to electrical
shock, and may also cause damage to property.
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia
in hot tubs and spas. This product is intended to control heaters with built-in high limit
circuits ONLY. Failure to do so may cause property damage or personal injury.
For units intended for use in other than single-family dwellings, a clearly labeled
emergency switch shall be provided as part of the installation. The switch shall be readily
accessible to the occupants and shall be installed at least five (5) feet (1.52 m) away,
adjacent to, and within sight of, the unit.
Except for listed spa-side remote controls, install a minimum of five (5) feet (1.52 m) from
the inside wall of the pool and spa.
For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety
Commission at (301) 504-7908 or visit www.cpsc.gov.
NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
Two Speed Pump Controls Notice (Title 20 Compliance)
Please read the following important Safety Instructions - When using two-speed pumps
manufactured on or after January 1, 2008, the pump’s default circulation speed MUST be set to the
LOWEST SPEED, with a high speed override capability being for a temporary period not to exceed one
normal cycle, or two hours, whichever is less.
CAUTION: IMPORTANT BATTERY INFORMATION
• Danger of explosion if battery is incorrectly replaced.
• ONLY USE a Pentair Water Pool and Spa (“Pentair”) replacement battery. Order Battery
(P/N 522054).
• Rechargeable Lithium-ion battery disposal: Unwanted lithium ion battery pack may be returned to
your local recycling center or the manufacturer for disposal.
• Dispose of used batteries according to the manufacturer’s instructions.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
FCC Standard - 47 CFR Part 15, Subpart C (Section 15.247). This version is limited to chapter 1 to chapter 11 by
specified firmware controlled in the U.S.A.
FCC non-modification statement:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
FCC RF Exposure requirements:
Notice for Virtual Cable (FCC ID: P4H-ICVC & IC: 4249A-ICVC): In order to comply with FCC/IC RF Exposure requirements,
a minimum separation distance of 8 in (20 cm) must be maintained between the equipment and all persons during normal
operation.
Afin de satisfaire aux exigences de la FCC/IC l’exposition RF, une distance de séparation minimale de 8 po (20 cm) doit être
maintenue entre l’équipement et toutes les personnes en fonctionnement normal.
Notice for Wireless Remote Control (FCC ID: P4H-ICHNDHLD & IC: 4249A-ICHNDHLD):
This portable transmitter with its antenna has shown compliance with FCC/IC SAR limits for general population / uncontrolled
exposure. The maximum listed SAR level is 0.88 W/kg (body). The antenna used for this device must not be co-located or
operating in conjunction with any other antenna or transmitter.
Cet émetteur portable avec son antenne a démontré la conformité aux limites de la FCC/IC SAR pour la population générale /
exposition non contrôlée. Le niveau maximal de SAR cotée est 0.88 W/kg (corps). L’antenne utilisée pour cet appareil ne doit
pas être co-implanté ou fonctionner en conjonction avec toute autre antenne ou émetteur.
v
Canada - Industry Canada (IC) - The IntelliCenter
Industry Canada. (1999). Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
The device complies with industry Canada’s License Exempt RSSs. Operation is subject to the following: (1) This device
may not cause interference; and (2) This device must accept interference that may cause undesired operation of the
device.
Le dispositif est conforme à la licence d’Industrie Canada Exempt CNR. Le fonctionnement est soumis à la suivante.
(1) Ce ne doit pas provoquer d’interférences ; et (2) Cet appareil doit accepter les interférences qui peuvent causer un
mauvais fonctionnement de l’appareil.
This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à
la norme NMB-003 du Canada. The term “IC” before the certification / registration number only signifies that the Industry
Canada technical specifications were met.
Instruction to User - The IntelliCenter Control System and the Wireless Control Panel has been tested and found to
comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. The IntelliCenter Control
System and Wireless Control Panel generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to
radio or television reception, which can be determined by switching the device off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
™
Control System and Wireless Control Panel complies with RSS210 of
and receiver.
IntelliCenter Control System Wireless Control Panel Installation Guide
vi
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
General Installation Information
1. All work must be performed by a licensed electrician, and must conform to all national, state, and
local codes.
2. Install to provide drainage of compartment for electrical components.
3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) must
be provided for these fixtures. Conductors on the load side of the ground-fault circuit-interrupter
shall not occupy conduit, junction boxes or enclosures containing other conductors unless such
conductors are also protected by a ground-fault circuit-interrupter. Refer to local codes for details.
4. A terminal bar stamped is located inside the supply terminal box. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply
service panel with a continuous copper wire equivalent in size to the circuit conductors supplying
this equipment (no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit
are intended to connect a minimum of one No. 8 AWG for US installation and two No. 6 AWG for
Canadian installations solid copper conductor between this unit and any metal equipment, metal
enclosures or electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open
all ungrounded supply conductors to comply with in accordance with the current National Electrical
Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local
installation codes and ordinances must also be adhered to. The disconnecting means must be
readily accessible to the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall of
the pool.
6. GAS HEATER: This automation control system is designed to supply high voltage (120 VAC / 240
VAC) to a gas heater and override the thermostat in the heater’s control circuit. This automation
control system is intended to control gas heaters with a high temperature limit switch(s) safety
circuit.
CUSTOMER SER
Customer Service
8 A.M. to 7.30 P M — Eastern and Pacific Times
Phone: (800) 831-7133
Fax: (800) 284-4151
Visit www.pentairpool.com
VICE / TECHNICAL SUPPORT
IntelliCenter Control System Wireless Control Panel Installation Guide
Technical Support
Sanford, North Carolina (8 A.M. to 7.30 P M ET)
Phone: (919) 566-8000
Fax: (919) 566-8920
Moorpark, California (8 A.M. to 4.30 P.M. PT)
Phone: (805) 553-5000 (Ext. 5591)
Fax: (805) 553-5515
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.