Pentair EZ100 User Manual

EZ100 EASYTOUCH OWNER’S MANUAL
4-Function Hand-Held Wireless Remote Control
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
SECTION I. APPLICATION ............................................................................................................................................... 2
SECTION II. KIT INCLUSION ............................................................................................................................................ 2
SECTION III. RECEIVER ....................................................................................................................................................... 2
SECTION IV. POWER CENTER ...........................................................................................................................................3
SECTION V. POWER ISOLATION CIRCUIT BOARD ....................................................................................................3
SECTION VI. CABLE SPLITTERS (OPTIONAL) .............................................................................................................. 3
SECTION VII. HAND-HELD REMOTE ................................................................................................................................ 3
SECTION VIII. USING THE HAND-HELD REMOTE .......................................................................................................... 3
SECTION IX. RECEIVER CIRCUIT BOARD ...................................................................................................................... 4
SECTION X. AUTOMATIC COUNTDOWN CYCLE (OPTIONAL) ............................................................................... 5
SECTION XI. CUSTOMIZING THE COMMUNICATION LINK ..................................................................................... 6
SECTION XII. TRANSMITTER BATTERY REPLACEMENT ........................................................................................... 6
SECTION XIII. TROUBLESHOOTING ................................................................................................................................... 7
WARNING
Before installing this product, read and follow all warning notices and instructions which are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
IMPORTANT
The Hand-held remote may be used with wet hands, but should never be submersed in water, as this could damage the unit. If accidental submersion occurs, dry unit out by removing battery cover and removing battery. Position unit so that water can drain out. Reassemble when completely dry.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
Rev. D 2-19-04 1 P/N 520041
SECTION I. APPLICATION
Used in conjunction with Compool CP100 and EasyTouch Control Systems.
Provides switching of four remote control circuits from a wireless hand-held remote.
It is typically used for activating the spa circulation, and for operating three auxiliary pieces of equipment (such as lights, jet pump, air blower, waterfall, etc.)
Each of the four functions on the hand-held remote has an “ON” and an “OFF” button.
SECTION II. KIT INCLUDES:
1-qty. Hand-held Remote (P/N 520018) 1-qty. Receiver (with 8 ft. flexible conduit with 2 –9½ ft. cables inside) 4-qty. Plastic Anchors (for mounting Receiver to a flat surface) 4-qty. Mounting screws (for mounting Receiver to a flat surface)
SECTION III. RECEIVER
The functional range of the wireless remote (from Hand-held Remote to Receiver) is approximately 150 ft. line-of-sight.
The Receiver should be mounted at a convenient location (on a flat surface) a minimum of 5 ft. above ground level to optimize the functional range of the Hand-held Remote.
CAUTION
The Receiver should be mounted a minimum of 8 to 10 feet away from any air blower, which may be part of the equipment set. The Receiver will not operate properly if it is close to a blower which is operating.
In order to mount the Receiver, it will be necessary to remove the two retaining screws located on the underside of the Receiver, and carefully slide the Receiver case up and off of its backplate. Temporarily position the backplate against its mounting surface so that the Receiver is oriented in an upright position (with antenna pointing upwards, and flexible conduit protruding from the bottom of the Receiver). The circuit board may need to be temporarily removed. Carefully disconnect the modular connectors at the bottom of the circuit board and slide the board out of the backplate. Use a pencil to mark the four mounting points. For mounting to stucco walls, drill 3/16 in. dia. holes. Insert the four plastic anchors (provided). Reposition the backplate over the mounting points and secure with the four mounting screws (provided). Carefully slide the circuit board back into the backplate and connect the modular connectors with the silver cable connector attached to Socket #1 (SILVER) and the black cable connector attached to Socket #2. Then slide the Receiver case back onto the backplate, and secure using the two retaining screws.
P/N 520041 2 Rev. D 2-19-04
SECTION IV. POWER CENTER
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
If your Compool electrical panel includes circuit breakers (almond colored steel enclosure), it is also required that the main power into the home be switched off at the main circuit breaker box.
Before starting the installation process, disconnect power by switching off all circuit breakers to all associated pool and spa equipment. Failure to do so may lead to severe electrical shock, which can result in death or severe personal injury.
Loosen the LOCK SCREW on handle of hinged faceplate in left-side of Power Center, and swing open to expose the low-voltage wiring compartment. If the Power Center incorporates a circuit breaker subpanel, it will be necessary to temporarily remove the breaker panel in order to access the low-voltage wiring compartment.
Insert the flexible conduit (attached to Receiver) into the low-voltage compartment by threading through the plastic bushing on the underside of the Power Center enclosure.
SECTION V. POWER ISOLATION CIRCUIT BOARD
Locate the two cables (one silver and one black) protruding from the flexible conduit. Each cable has a modular connector attached. If the Control System incorporates an Indoor Remote, disconnect any cables going to Socket #2 of the Power Center circuit board. Plug the short cable (BLACK) from the Power Isolation circuit board into Socket #2. Plug the black cable from the RF receiver into the socket marked “EZ-WIRELESS” of the Power Isolation circuit board. The Power Isolation PCB has an additional socket to accommodate the Indoor Remote cable from Socket #2 marked “CP100”. If there is no Indoor Remote, the silver cable for the receiver may be plugged directly into Socket #1 of the Power Center circuit board. If the Control System incorporates an Indoor Remote, it will be necessary to use a Cable Splitter for Socket #1. See SECTION VI. CABLE SPLITTERS (Optional).
SECTION VI. CABLE SPLITTERS (Optional)
If the Control System incorporates an Indoor Remote, disconnect any existing Indoor Remote cables from Socket #1. It will be necessary to use a Cable Splitter (P/N 6CONDDUAL) to connect to the Power Center circuit board.
Plug the short cable (attached to single-connector end of each Cable Splitter) into Socket #1. Plug the cable from the Indoor Remote and the silver cable from the receiver into the Cable Splitter sockets.
SECTION VII. HAND-HELD REMOTE
The Hand-held Remote will control four circuits.
SPA button activates the Spa circuit (duplicates Spa Button on Optional Indoor Remote).
“A” button activates Auxiliary 1 circuit (duplicates Button 1 on Optional Indoor Remote).
“B” button activates Auxiliary 2 circuit (duplicates Button 2 on Optional Indoor Remote).
“C” button activates Auxiliary 3 circuit (duplicates Button 3 on Optional Indoor Remote).
Each of the four functions on the hand-held remote has an “ON” and an “OFF” button.
It is possible to incorporate a 30-minute or 90-minute countdown cycle for the Spa and/or Auxiliary 1 circuit (useful if Aux1 is used for a jet pump or air blower). In this instance, whenever those circuits are turned on, they will automatically shut down (at the end of the countdown cycle) without having to push the “OFF” button.
In order to incorporate the countdown feature, it is necessary to make adjustments to the circuit board located inside the Receiver unit.
SECTION VIII. USING THE HAND-HELD REMOTE
To activate a circuit, press and hold the appropriate “ON” button for at least a full second. To deactivate, press and hold the “OFF” button in the same manner.
Rev. D 2-19-04 3 P/N 520041