Figure 1 TwinFigure 2 TripleFigure 3 QuadFigure 4 Quad Plus
®
HIGH FLOW CSR FILTER SYSTEMS
SELECT A MOUNTING LOCATION
1. Give consideration to the weight of the unit when
operating (filled with water). Operating weights of
Everpure High Flow CSR Systems are:
• Twin System - 45 lbs (20.4 kg)
• Triple System - 47 lbs (21.3 kg)
• Quad System - 49 lbs (22.2 kg)
• Quad Plus System - 49 lbs (25.2 kg) + separate
surge/storage tank @ 60 lbs (27.2 kg)
INSTALLATION
1. Use the predrilled mounting holes in the manifold
bracket as guides. Mark and drill anchor holes. Mount
securely. See Figures 5-8.
2. Shut off power to equipment. If system is an Everpure
High Flow CSR Quad Plus (separate Everpure SR-X
Feeder and surge/storage tank), proceed to step 4.
3. Connect outlet ports of High Flow system to equipment
served per the instructions below. Always use NSF
approved pipe dope or plumber tape at all connections.
Use a backup wrench on all fittings while connecting to
avoid stress on the system components.
• The cross fitting before the SR-X Feeder has a
threaded outlet on top. Connect a minimum 1/2" I.D.
line from this outlet to fountain beverage equipment.
• The cross fitting has a flushing valve installed on the
bottom. Connect tubing to the flushing valve and run
to drain.
NOTE: Some municipal plumbing codes and good
sanitary practices require an air gap at the drain
termination point.
2. The location should allow for (See Figures 1-8):
• Minimum clearance of 2-1⁄2" (6.4 cm) under the
cartridge(s) so it can be lowered for removal
and replacement.
• Adequate space for “in” and “out” water line
connections. Be near a drain for flushing and near a
110V outlet if the optional Everguard™ Low Pressure
Alarm is used.
• Additional mounting and floor space for the separate
Everpure SR-X Feeder and surge/storage tank
(Quad Plus).
• Connect the outlet of the SR-X Feeder to the ice
machine make-up water (not condenser water) line
and coffee brewing equipment. Proceed to step 5.
4. For Everpure High Flow CSR Quad Plus System, connect
outlet to equipment served per the instructions below.
Always use a NSF approved pipe dope or plumber tape at
all connections. Use a backup wrench on all fittings while
connecting to avoid stress on the system components.
• Locate and mount the separate SR-X Feeder between
the High Flow CSR system and the ice machine.
Make-up water (not condenser water) line and coffee
brewing equipment.
• A tee fitting is located in the system header before
the surge tank isolation and flushing valve. Using
minimum 1/2" I.D. line, connect the outlet of this tee to
the fountain beverage and remote SR-X Feeder line.
IMPORTANT: Install a tee in this service water line to
separate the fountain water feed from the ice
machine/coffee brewer water feed.
In Massachusetts, a backflow preventer is
required for this installation.
FILTRATION & PROCESSING SOLUTIONS
HIGH FLOW CSR FILTER SYSTEMS INSTALLATION AND OPERATION GUIDE
1
30"
• Connect one branch of the service water tee to the
fountain beverage equipment. Connect the other
branch of the tee to the inlet of the SR-X Feeder.
Connect the outlet of the SR-X Feeder to the ice
machine make-up water (not condenser water) line
and coffee brewing equipment.
• The surge tank isolation and flushing valve is located
at the end of the system header. Using fittings and
hose provided, connect one branch of the valve to the
surge/storage tank. Connect a hose from the other
(flushing) branch and run to drain.
NOTE: Some municipal plumbing codes and good
sanitary practices require an air gap at the drain
termination point.
5. The surge/storage tank is pre-pressurized to 20 psi
(1.4 bar). Check pressure and adjust as necessary.
6. Install a manual shut-off valve leading to the system for
servicing and connect minimum 1/2" I.D. (3/4" for quad)
water line to the system inlet.
7. The optional EverguardTM Low Pressure Alarm (LPA)
consists of a pressure switch, audible/visual alarm box
and a power adapter. It is designed to detect a fixed
low pressure, approx. 20 psi (1.4 bar), condition as an
indication of loss of system outlet pressure either due
to an intentional shut-down or excess fouling of the
water filters, thus indicating the need for filter cartridge
change-out. If the system is equipped with the LPA,
follow these steps:
• Determine location of a convenient 110 VAC outlet to
plug in the LPA power adapter.
• Remove the protective rubber cap from the pressure
switch installed in the system header assembly. Insert
the wires from the LPA unit through the cap and
connect them to the terminals on the pressure switch.
Either wire can be connected to either terminal.
Replace the cap.
• Plug the LPA power adapter into an outlet. The audible
alarm should activate. Push the reset switch
to silence.
• Unplug the LPA unit.
8. Shut off the system inlet valve located on the inlet of the
prefilter head.
9. Check to be sure the o-ring on the prefilter housing
is sufficiently lubricated. Use a good grade of silicone
lubricant, if needed. Position the Everpure EC210
prefilter cartridge on guide seat in the bottom of the
bowl. Then thread the bowl into the head by hand. Use a
sump wrench to snug the bowl onto the head.
10. Install only genuine Everpure carbon filter cartridge(s)
into the filter head(s) following directions on the
cartridge label or as shown in the Cartridge Change
illustrations. Install the Everpure® SS-10 Scale Inhibitor
cartridge into the Everpure SR-X housing.
11. Turn on inlet water to the filter system and check
for leaks.
12. Open the flushing valve and flush the cartridge(s) by
running water through at full force for five (5) minutes.
This will set the filtering media and purge any air and
fines, insuring maximum filter life. See illustrations.
13. After flushing, close the flushing valve, turn on power
to equipment and plug the LPA (if so equipped) into the
electrical outlet. The system is ready for operation.
Check for compliance with state and local laws and regulations. Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
For installations in Massachusetts, the Commonwealth of
Massachusetts Plumbing Code 248 CMR shall be adhered to.
Consult your licensed plumber for installation of the system.
This system and its installation must comply with state and
local regulations.
DIMENSIONS
25.80"
FOUNTAIN
OUTLET
3/4" FNPT
INLET
3/4" FNPT
Figure 5 Twin
2 HIGH FLOW CSR FILTER SYSTEMS INSTALLATION AND OPERATION GUIDE
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
25.59"
INLET
3/4" FNPT
Figure 6 Triple
FOUNTAIN
OUTLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
25.59"
INLET
31.38"
3/4" FNPT
34"
OUTLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
25.69"
INLET
3/4" FNPT
INSERT TEE FITTING.
ONE OUTLET TO
FOUNTAIN,
ONE OUTLET TO SRX.
OUTLET
3/4" FNPT
INLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
Figure 7 Quad
CARTRIDGE CHANGE DETERMINATION
• Replace the prefilter cartridge whenever it becomes
excessively dirty (observed visually or by flow restriction).
Follow the change instructions provided with the
cartridge.
• Replace carbon filter cartridges when capacity is
reached or when flow becomes inadequate, but at least
annually. All carbon filter cartridges on multiple cartridge
systems should be changed at the same time. Change
the Everpure SS-10 cartridge when product level in the
cartridge drops below 1/2" from the bottom of the bowl.
• The system pressure gauge or optional Everguard Low
Pressure Alarm (LPA) provides a quick, simple means
of determining when the filter cartridge(s) should be
checked. Installed on the system outlet manifold, the
gauge or LPA can be used to monitor both dynamic
(flowing) and static (line) pressure.
• The cartridge(s) should be changed when the pressure
gauge is in the red area while equipment is in operation,
and yet the needle shows adequate line pressure between
cycles.
• Observe the needle during the next equipment on cycle.
If the needle registers adequate pressure, it can be
assumed that the temporary low-pressure condition
was caused by a brief power failure or other incoming
pressure disruption.
• If the low pressure condition is not due to an external
condition, check/change the prefilter first. If the low
pressure condition is still not corrected, change the
carbon filter cartridges.
Figure 8 Quad Plus
FLUSHING
For maximum life, all carbon filter cartridges must be
flushed for five (5) minutes at full flow before use.
ALL NEW CARTRIDGES MUST BE FLUSHED AFTER EACH
CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE!
If the cartridges are new, have been properly flushed and
both needle and follower register inadequate pressure, or the
LPA is sounding, you may be experiencing inadequate water
pressure or some restriction may exist in the inlet water
line. In either case, the incoming water pressure must be
improved to receive optimum filter life.
COMPLETE CARTRIDGE CHANGE INSTRUCTIONS CAN BE
FOUND ON THE FILTER CARTRIDGE LABEL.
Not for residential use. For food service applications only.
REPLACEMENT PARTS
Contact your local Pentair® Everpure® dealer for filter
cartridges or system replacement parts.
DESCRIPTIONPART NUMBER
Inlet/Outlet Pressure GaugeEV3114-09
Inlet/Flushing ValveEV3114-07
O-ring for Prefilter or SR-XEV3112-40
Prefilter BowlEV3112-38
SR-X BowlEV3112-39
LPA Pressure SwitchEV3016-41
WrenchEV3112-41
3 HIGH FLOW CSR FILTER SYSTEMS INSTALLATION AND OPERATION GUIDE