Pentair Everpure QL1-BH2, Everpure QL2-BH2, Everpure QL3-BH2, Everpure QL3B-BH2 User Manual

EVERPURE
The Everpure BH2 Water Filters reduce chlorine tastes and odors and other substances that produce off-tastes and odors in coffee. The BH2 also reduces dirt and rust, and reduces the formation of limescale* which builds up on the brewer heating elements and in the reservoir.
®
QL1-, QL2-, QL3-, QL3B-BH2 WATER FILTERS
INSTALLATION
The following instructions provide for installation of a QL1-, QL2-, QL3-, QL3B-BH2 Filter regardless of whether or not the brewer is already installed. The label on the BH2 Cartridge illustrates and explains the procedure for cartridge insertion and removal into the filter head. The filter cartridge should be placed into the head after the system has been installed.
1. Install the filter as close to the brewer as possible. Do not connect this filter to any other equipment. Connect only to the cold water line and do not expose it to high temperatures.
2. Select a location for the filter, nominally 4 x 4 x 18 inches (10 x 10 x 45.7 cm) long, including a 2.5-inch (6.3 cm) drop-down for cartridge changes. Write the installation date and anticipated cartridge replacement date in the space provided on the cartridge label. The cartridge should be replaced every 12 months or after 6,000 pots (3,000 gallons, 11,356 L) have been brewed, whichever occurs first.
3. If required, shut off the incoming water supply and relieve pressure in the tubing. Cut the tubing, allowing a 4-inch (10 cm) space for the filter installation between the water supply and the brewer water inlet.
4. Install appropriate fittings into each port of the head. Use a good grade of pipe dope or plumber tape on the body threads. Do not overtighten the fittings.
5. Position the head assembly so that the arrow shown on top of the head corresponds to the direction of water flow and attach the incoming cold water supply to the inlet of the head.
6. Connect the filter outlet to the brewer water inlet line. Use compression or flare fittings to make water connections to the brewer.
7. Mount the head to the wall using the screws and star washers provided.
8. Install the cartridge into the head following the instructions on the cartridge label.
9. Turn on the water and check for leaks.
NOTE: The cartridge must be flushed before use by running water through it at maximum flow for three minutes to purge
the cartridge of air.
Rated Service Flow: 0.5 gpm (1.9 Lpm)
Temperature: 35-100°F, (2-38°C).
Min./Max. Line Pressure: 10-125 psi (0.7-8.6 bar), non-shock.
Capacity of a Single Unit: 3,000 gallons (11,360 liters).
For cold water use only.
This water filtration system must be maintained in accordance with the manufacturer’s instructions, including the timely replacement of filter cartridges.
This product is intended for commercial use only. Home or similar consumer use VOIDS THE WARRANTY.
Check for compliance with state and local laws and regulations. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The term ‘bacteriostatic’ indicates that the system limits the passage or growth of bacteria that may already exist in the incoming water. It does not mean that the water leaving the system is safer to drink than the water entering the system.
FILTRATION & PROCESSING SOLUTIONS
QL1-, QL2-, QL3-, QL3B-BH2 WATER FILTE R IO GUIDE
REPLACEMENT PARTS
A
Contact your local Pentair® Everpure® dealer for filter cartridges or system replacement parts.
Key
Letter Description Part Number
A QL3 Head Assembly EV3076-37
B BH2 Filter Cartridge EV9612-00
C Mounting Screw EV3061-96
D Star Washer EV3055-34
F Bracket Screw EV3062-03
E
D
C
F
B
Systems Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for the reduction of:
Standard No. 42 — Aesthetic Effects Standard No. 53 — Health Effects
Bacteriostatic Effects
Chemical Reduction
Taste and Odor Chlorine
Mechanical Filtration
Nominal Particulate Class I
Mechanical Filtration
Cyst
2 QL1-, QL2-, QL3-, QL3B-BH
2
WATER FILTE R INSTALLATION AND OPERATION GUIDE