Pentair EV9771-21, EV9771-22, EV9771-24, EV9771-23 Installation And Operation Manual

EVERPURE
®
COLDRINK® - 7CLM+ SERIES WATER FILTRATION SYSTEMS
Coldrink 1 - 7CLM
+
System Coldrink 2 - 7CLM+ System
Coldrink 3 - 7CLM+ System Coldrink 4 - 7CLM+ System
INTRODUCTION
The Everpure Coldrink - 7CLM+ Series Water Filtration Systems are designed to treat up to 50,400 gals (190,784 L) of water. These systems are NSF Certified to reduce chloramines and to reduce a variety of other contaminants making them
excellent filters for fountain beverage, frozen carbonated beverage and drinking water applications.
INSPECTION
Before mounting the Coldrink - 7CLM+ Series System, inspect the parts. Use the table and illustration provided to verify the parts and quantities. If any parts are missing, contact Customer Service at 630.307.3000 or by email at CSeverpure@pentair.com.
Parts
Coldrink 1
- 7CLM
EV9771-21 EV9771-22 EV9771-23 EV9771-24
+
Coldrink 2
- 7CLM
+
Coldrink 3
- 7CLM
+
Coldrink 4
- 7CLM
+
1
1. Manifold and Bracket 1 1 1 1
2. 20-inch Prefilter Bowl 1 1 1 1
3. 20-inch EC-210 Prefilter 1 1 1 1
+
4. 7CLM
Filter Cartridge 1 2 3 4
5. Tubing, 1/2" O.D. 1 1 1 1
2
3
4
5
6. Hose Clamp 1 1 1 1
6
System Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of:
Standard No. 42 — Aesthetic Effects
Chemical Reduction
Taste and Odor Chlorine Chloramines
Mechanical Filtration
Nominal Particulate Class III
FOODSE RV IC E
COLDRINK - 7CLM+ SERI ES SYSTEMS INSTALLATION AND OPERATIONS GUIDE
SELECTING A MOUNTING LOCATION
21.5 inches
1. Give consideration to the weight of the unit when operating, i.e. filled with water. Operating weights of the Coldrink -
+
7CLM
Series System are:
• Coldrink 1 - 7CLM
• Coldrink 2 - 7CLM
• Coldrink 3 - 7CLM
• Coldrink 4 - 7CLM
+
System - 28.4 lbs (12.88 kgs)
+
System - 50.4 lbs (22.86 kgs)
+
System - 73.7 lbs (33.43 kgs)
+
System - 97.1 lbs (44.04 kgs)
2. The location should allow for:
• Minimum clearance of 2.5 inches (6.3 cm) under the cartridge(s) so it can be lowered for removal and replacement.
• Adequate space for “in” and “out” water line connections.
• Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard
TM
Low Pressure Alarm
(LPA) is used.
DIMENSIONS
Inlet
3/8" FNPT
Prefilter
(Inside Sump)
14 inches (35.5 cm)
Outlet
3/8" FNPT
25 inches (63.5 cm)
Primary
Filter
Cartridge
Inlet
3/4" FNPT
(54.6 cm)
Coldrink 1 - 7CLM+ Series System Coldrink 2 - 7CLM+ Series System
29.4 inches (74.5 cm)
Inlet
3/4" FNPT
25.75 inches (65.4 cm)
Outlet
3/4" FNPT
25.59 inches (64.9 cm)
Inlet
3/4" FNPT
Outlet
3/4" FNPT
Outlet
3/4" FNPT
25.59 inches (64.9 cm)
25.59 inches (64.9 cm)
Coldrink 3 - 7CLM+ Series System Coldrink 4 - 7CLM+ Series System
2 COLDRINK - 7CLM
+
SERI ES SYSTEMS INSTALLATION AND OPERATION GUIDE
INSTALLATION
Flow
Single System
Flow
Twin System
Flow
Flow
Flow
1
Mount to Wall
NOTE: Use correct
fasteners to mount securely.
NOTE: Use correct
fasteners to mount securely.
28.4 lbs (12.88 kgs) Operating Weight
50.4 lbs (22.86 kgs) Operating Weight
Triple System
Flow
Quad System
Flow
Flow
NOTE: Use correct
fasteners to mount securely.
NOTE: Use correct
fasteners to mount securely.
73.7 lbs (33.43 kgs) Operating Weight
97.1 lbs (44.02 kgs)
Operating Weight
+
SERI ES SYSTEMS INSTALLATION AND OPERATION GUIDE
3 COLDRINK - 7CLM
2
Attach Water Lines
MNPT
Fittings
NOTE: Apply plumbers tape to all
threaded connections.
Flushing
Valve
3
Inspect O-Ring
NOTE: Check to be sure o-ring
is in place.
4
Insert Filter
NOTE: Be sure filter
is seated.
5
Attach and Tighten Prefilter
NOTE: Hand tighten.
+
SERI ES SYSTEMS INSTALLATION AND OPERATION GUIDE
4 COLDRINK - 7CLM