Pentair 175K BTU/HR, 200K BTU/HR HD ASME, 200K BTU/HR ASME, 250K BTU/HR, 300K BTU/HR, 400K BTU/HR Installation And User Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
1
MASTERTEMP POOL AND SPA HEATER
®
INSTALLATION AND USER’S GUIDE
FOR YOUR SAFETY - READ BEFORE OPERATING
If you do not follow these instructions exactly , a fire or explosion may result, causing
property damage, personal injury or loss of life. For additional free copies of this
manual; call (800) 831-7133.
FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualified inpool/spa
heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Pentair
Aquatic Systems strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty.
Improper installation, adjustment, alteration, service or maintenance can cause
propertydamage, personal injury or death. Installation and service must be performed
by a qualified installer , service agency or the gas supplier.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
FOR
YOUR
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire dep artment.
SAFETY
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity
of this or other appliances.
Rev.M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
Pentair Water Pool and Spa, Inc.
•(800) 831-7133 or (805) 553-5000
2
Customer Service and Tecnincal Support
If you hav e questions about ordering P entair Quality Water Systems replacement parts, and
pool
products, please call:
Phone: (800) 831-7133
Fax: (800) 284-4151
(8 A.M. to 7:00 PM Eastern Time/P acific Time)
Web sites: www.pentairpool.com - www.staritepool.com
P/N 472592 Rev. M 1/2015
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Contents
Section 1. Heater Identification Information .......................................................................4
Section 2. Warning and Safety Information .........................................................................5
Important Notices.................................................................................................................................................................................5
Warranty Information ............................................................................................................................................................................5
Consumer Information and Safety Information ......................................................................................................................................6 - 9
General Specifications .........................................................................................................................................................................9
Putting the Heater into Service ............................................................................................................................................................10
Water Connections ...............................................................................................................................................................................13
Below Pool Level Installation ................................................................................................................................................................13
Gas Connections .................................................................................................................................................................................14
Gas Pipe Sizing ...................................................................................................................................................................................15
T esting Gas Pressure/Gas Pressure Requirements .............................................................................................................................15-16
Outdoor Installation (US and Canada) / Heater Clearances ..................................................................................................................16
Indoor Venting — General Requirements (Category I and Category III requirements) .........................................................................18
Heater Clearances — General Requirements (Indoor Installation for US or Outdoor Shelter for Canada) .............................................18
Combustion Air Supply /Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation).....................................................................19-20
Corrosive V apors and Possible Causes ................................................................................................................................................20
V ent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada) ........................................................................................21
V ertical Venting - Negative Pressure ...................................................................................................................................................21 - 23
Horizontal or V ertical Venting - Positive Pressure................................................................................................................................24
Connecting Special Gas Venting ..........................................................................................................................................................24 - 26
Garage or Utility Room Installation .......................................................................................................................................................27
Control Panel Indexing .........................................................................................................................................................................28
Final Installation Check ........................................................................................................................................................................28
Fireman’s Switch Connection/Remote Control Connections..................................................................................................................
Basic System Operation ......................................................................................................................................................................33
To Turn Off Gas to Appliance...............................................................................................................................................................34
Initial Troubleshooting and Troubleshooting Chart .................................................................................................................................38
Heater Will Not Fire Troubleshooting ....................................................................................................................................................39 - 42
LED Diagnostics ..................................................................................................................................................................................43 - 44
Care and Maintenance..........................................................................................................................................................................46
Pressure Relief V alve...........................................................................................................................................................................46
After Start-Up ......................................................................................................................................................................................47
Spring, Fall and Winter Operation .........................................................................................................................................................47
Maintaining Pool T emperature...............................................................................................................................................................48
Energy Saving Tips..............................................................................................................................................................................49
Chemical Balance ................................................................................................................................................................................ 48 - 49
Replacement Parts .............................................................................................................................................................................. 50 - 54
...........................................29
3
30
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
4
Section 1. Heater Identification Information
Section 1: Heater Identification Information
To identify the heater, see rating plate on the inner front panel of the heater. There are two designators for each
heater, one is the
a. Heater Identification Number (HIN)
The following example simplifies the identification system:
1) MT : MasterTemp
2) Model Size : (175, 200, 250, 300 or 400) : Input rating (Btu/hr) X 1000
3) Fuel Type : (LP = Propane gas or NA = Natural gas)
4) Construction :(STD = Standard Model)
HEATER IDENTIFICATION INFORMATION — (HIN)
Model Number and the other is the Heater Identification Number (HIN).
(HD = Heavy Duty Model)
(ASME = ASME Certified Model)
(HD ASME = Heavy Duty ASME Model)
H. I. N.
HEATER IDENTIFICATION NUMBER
ID DESIGNATOR FOR PENTAIR AQUATIC SYSTEMS MASTERTEMP HEATERS
Example:
1 2 3 4
MT250NAASME
STD = STANDARD MODEL
CONSTRUCTION =
FUEL TYPE =
MODEL SIZE = BTU INPUT in 1000 of BTU / HR
HD = HEAVY DUTY MODEL
ASME = ASME CERTIFIED MODEL
HD ASME = HEAVY DUTY ASME MODEL
NA = NATURAL GAS
LP = PROPANE GAS
®
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
MT = MASTERTEMP
Section 2.Warning and Safety Instructions
Section 2: Warning and Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
5
MASTERTEMP
®
Pool and Spa Heater
Congratulations on your purchase of the MasterT emp Pool and Spa Heater. Proper installation and service of your new
heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MasterTemp heater
is a compact, lightweight, efficient, induced-draft, gas fired high performance pool and spa heater that can be directly
connected to schedule 40 PVC pipe. The MasterTemp heater also comes equipped with the Pentair multifunction
temperature controller which shows, at a glance, the proper functioning of the heater. All MasterTemp heaters are
designed with a direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. The
MasterTemp heater requires an external power source (120/240 VAC 60 Hz) to operate.
SPECIAL INSTRUCTIONS TO OWNER: Retain this manual for future reference. This instruction manual provides
operating instructions, installation and service information for the MasterT emp high performance heater. The information
in this manual applies to all MasterTemp heater models. READ AND REVIEW THIS MANUAL COMPLETELY,
it is very important that the owner/installer read and understand the section covering installation instructions, and recognize
the local and state codes before installing the MasterTemp heater. Its use will reduce service calls and chance of injury
and will lengthen product life. History and experience has shown that most heater damage is caused by improper installation
practices.
IMPORT ANT NO TICES
For the installer and operator of the MasterTemp heater: The manufacturer’s warranty may be void if, for any
reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual. If you
need any more information, or if you have any questions regarding to this pool heater, please contact Pentair Aquatic
Systems at (800) 831-7133.
W ARRANTY INFORMA TION
The MasterTemp pool and spa heater is sold with a limited factory warranty. Specific details are described on the
warranty registration card which is included with the product. Return the warranty registration card after filling in
the serial number from the rating plate inside the heater.
Pentair Aquatic Systems high standards of excellence include a policy of continuous product improvement resulting
in your state-of-the-art heater. We reserve the right to make improvements which change the specifications of the
heater without incurring an obligation to update the current heater equipment.
These heaters are designed for the heating of chlorine, bromine or salt system swimming pools and spas or
in non-stationary installations, and should never be employed for use as space heating boilers or general
purpose water heaters. The manufacturer’s warranty may be void if, for any reason, the heater is improperly
installed and/or operated. Be sure to follow the instructions set forth in this manual.
CAUTION
OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 68° F. WILL CAUSE HARMFUL
CONDENSATION AND WILL DAMAGE THE HEATER AND VOID THE WARRANTY. Do not use the heater to protect
pools or spas from freezing if the final maintenance temperature desired is below 68° F., as this will cause condensation
related problems.
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
6
Section 2. W arning and Saf ety Instructions
CODE REQUIREMENTS
Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code,
ANSI Z223.1 and the latest edition of the National Electrical Code, NFPA 70 (US).
Installation in Canada must be in accordance with the latest CAN/CGA-B149.1 or .2 and CSA C22.1 Canadian
Electric Code, part 1.
The heater, when installed, must be electrically grounded and bonded in accordance with local codes, or, in absence of
local codes, with the National Electrical Code, ANSI/NFPA70 (US) or in Canada in accordance with the Canadian
Electric Code, part 1.as applicable.
D ANGER
CARBON MONOXIDE GAS IS DEADLY – Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous,
poisonous gas you cannot see or smell.
CONSUMER INFORMA TION AND SAFETY
WARNING
The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous.
See below for water temperature guidelines before setting temperature.
1 .Spa or hot tub water temperatures should never exceed 104° F (40° C). A temperature of 100° F (38° C) is considered safe for a
healthy adult. Special caution is suggested for young children.
2 .Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness
and subsequently result in drowning.
3 .Pregnant women beware! Soaking in water above 102° F (39° C) can cause fetal damage during the first three months of pregnancy
(resulting in the birth of a brain-damaged or deformed child). Pregnant women should stick to the 100° F (38° C) maximum rule.
4.Before entering the spa or hot tub, the user should check the water temperature with an accurate thermometer. Spa or hot tub
thermostats may err in regulating water temperatures by as much as 4° F (2.2° C).
5.Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their
physician's advice before using spas or hot tubs.
6 .Persons taking medication which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not use spas
or hot tubs.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater .
Do not use this heater if any part has been under water. Immediately call a qualified service technician to
inspect the heater and to replace any part of control system and gas control which has been under water .
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
W ARNING
Section 2.Warning and Safety Instructions
7
SAFETY INFORMA TION
The MasterTemp® pool heaters are designed and manufactured to provide many years of safe and reliable service when
installed, operated and maintained according to the information in this manual. Throughout the manual, safety warnings and
cautions are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions.
DANGER —
CARBON MONOXIDE GAS IS DEADLY
READ OWNERS MANUAL COMPLETELY BEFORE OPERATING
THIS PRODUCT MUST BE INSTALLED AND SERVICED BY A PROFESSIONAL SERVICE
TECHNICIAN, QUALIFIED IN POOL HEATER INSTALLATION. Some jurisdictions require that
installers be licensed. Check with your local building authority about contractor licensing requirements.
Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause
serious injury or death. Improper installation and/or operation will void the warranty.
Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas
you cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness,
headache, nausea, weakness, sleepiness, muscular twitching, vomiting and inability to think clearly.
IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY TURN OFF THE POOL
HEATER, LEAVE THE VICINITY OF THE POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY.
THE POOL HEATER MUST BE THOROUGHLY TESTED BY A GAS PROFESSIONAL BEFORE
RESUMING OPERATION.
EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH.
NEVER use this pool heater indoors without specified ventilation system (and properly installed vent pipe).
NEVER use this pool heater in the home or in partly enclosed areas (such as garages), unless
the specified ventilation system is used. If used outdoors, install far from open windows, doors,
vents and other openings.
Pentair strongly recommends that all vents, pipes and exhaust systems be initially and periodically
tested for proper operation. This testing can be accomplished by using a hand-held carbon monoxide
meter and/or by consulting with a gas professional.
Pool heaters must be used in conjunction with carbon monoxide detectors installed near the pool heater.
The carbon monoxide detectors must be periodically inspected for proper operation so as to insure
continued safety. Broken or malfunctioning carbon monoxide detectors must be replaced immediately.
WARNING — FOR YOUR SAFETY
This product must be installed and serviced by a professional service technician, qualified in pool
heater installation. Some jurisdictions require that installers be licensed. Check with your local
building authority about contractor licensing requirements. Improper installation and/or operation
could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper
installation and/or operation will void the warranty.
WARNING —
This heater is equipped with an unconventional gas control valve that is factory set with a
manifold pressure of -.2 inches wc. Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of life. Installation or service must
be performed by a qualified installer, service agency or the gas supplier. If this control is replaced, it
must be replaced with an identical control.
Do not attempt to adjust the gas flow by adjusting the regulator setting.
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
8
SAFETY INFORMA TION, (cont’d.)
WARNING —
WARNING —
Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a
heater set up for natural gas on propane gas or vice versa. Only qualified service technicians should
attempt to convert heater from one fuel to the other. Do not attempt to alter the rated input or type of
gas by changing the orifice. If it is necessary to convert to a different type of gas, consult your Pentair
dealer. Serious malfunction of the burner can occur which may result in loss of life. Any additions,
changes, or conversions required in order for the appliance to satisfactorily meet the application
needs must be made by a Pentair dealer or other qualified agency using factory specified and
approved parts. The heater is available for use with natural gas or LP (propane) gas only. It is not
designed to operate with any other fuels. Refer to the nameplate for the type of gas the heater is
equipped to use.
• Use heater only with the fuel for which it is designed.
• If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier
before putting the heater into operation.
Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes,
paints, or other volatile flammable liquids near heater or in the same room with heater.
Section 2.Warning and Safety Instructions
WARNING —
WARNING —
WARNING —
CAUTION —
Risk of explosion if unit is installed near propane gas storage. Propane (LP) gas is heavier
than air. Consult local codes and fire protection authorities about specific installation requirements
and restrictions. Locate the heater away from propane gas storage and filling equipment as specified
by the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2
(latest edition) or ANSI/NFPA 58 (latest edition).
Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks.
Only qualified service technicians should attempt to service the heater, as leakage of exhaust
products or flammable gas may result from incorrect servicing.
Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly
when installing heater. Do not use a drafthood with this heater, as the exhaust is under
pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room
housing the heater. The heater is supplied with an integral venting system for outdoor installation.
A vent conversion kit (See Page 24 for Part Numbers for Conversion Kits) is available for installations
in enclosures (Canada) or indoors (U.S.). Use the specified venting, and only the specified venting,
when heater is installed in an enclosure or indoors. In Canada, this pool heater can only be installed
outdoors or in an enclosure that is not normally occupied and has no openings directly into occupied
areas. See Page 19 for enclosure venting requirements.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Wiring errors can also destroy the control board.
• Connect heater to 120 or 240 Volt, 60 Hz., Single Phase power only.
• Verify proper operation after servicing.
• Do not allow children to play on or around heater or associated equipment.
• Never allow children to use the pool or spa without adult supervision.
• Read and follow other safety information contained in this manual prior to operating this pool
heater.
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Section 2.Warning and Safety Instructions
9
CONSUMER INFORMA TION AND SAFETY
WARNING
The U.S. Consumer Product Safety Commission warns that carbon monoxide is an "invisible killer". Carbon monoxide
is a colorless and odorless gas.
1. Carbon monoxide is produced by burning fuel, including natural gas and propane.
2. Proper installation, operation and maintenance of fuel-burning appliances in the home is the most important
factor in reducing carbon monoxide poisoning.
3. Be sure that fuel burning appliances such as heaters are installed by professionals according to manufacturer's
instructions and codes.
4. Always follow the manufacturer's directions for safe operation.
5. Have the heating system (including vents) inspected and serviced annually by a trained service technician.
6. Examine vents regularly for improper connections, visible cracks, rust or stains.
7. Install battery-operated carbon monoxide alarms. The alarms should be certified to the requirements of the
most recent UL, IAS, CSA and IAPMO standard for carbon monoxide alarms. Test carbon monoxide alarms
regularly and replace dead batteries.
GENERAL SPECIFICA TIONS
NOTICE:
•Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty.
•The Combination Gas Control Valve on this heater differs from most appliance gas controls. If it must be replaced,
for safety reasons replace it only with an identical gas control.
•The access door panels must be in place to provide proper ventilation. Do not operate the heater for more than five (5)
minutes with the access door panels removed.
•This heater is design certified by CSA International as complying with the Standard for Gas Fired Pool Heaters,
ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas.
•The heater is designed for the heating of chlorine, bromine or salt system swimming pools and spas. It should NOT be
used as a space heating boiler, or general purpose water heater.
•The heater is design certified by CSA International for installation on combustible flooring. Specified minimum
clearances must be maintained to combustible surfaces (see “Heater Clearances”, page 18).
The heater should be located in an area where leakage of the heater or connections will not result in damage to the
•
area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow.
•The heater may not be installed within 5 ft. (1.5M ) of the inside surface of a pool or spa unless it is separated by a solid
fence, wall or other permanent barrier.
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
10
Section 3: Installation Instructions
HEA TER DESCRIPTION
Section 3.Installation Instructions
Figure 1 is a diagram of the heater showing how it operates. Precisely
Gas
matched orifice plates meter the air and gas into the mixer. The
blower draws the air and gas through the mixer and forces it into
the burner’s flame holder. A sealed heat exchanger surrounds the
flame holder, dischar ging exhaust gases out the flue.
T wo inch PVC water piping connects directly to the manifold/header
on the heat exchanger using 2" PVC slip unions provided with the
heater. The outer manifold remains cool; no heat sinks are required.
Inlet
(Cold
Water)
Air
Mixer
Blower
Exhaust
A thermal regulator and an internal bypass regulate the water flow
through the heat exchanger to maintain the correct outlet
temperature. The heater operator control panel board assembly is
located on top of the heater.
SEQUENCE OF OPERA TION
Outlet
(Mixed
Water)
Burner
Heating Coils
An electronic temperature sensing thermistor in the manifold
adapter inlet controls the heater operation. When the inlet water
Figure 1.
temperature drops below the temperature set on the operating
control, the burner controller supplies power to the combustion
air blower through a series of safety interlocks. The interlocks consist of:
• the pressure switch (PS), which senses that the pump is running,
• the high limit switch (HLS), which opens if the heat exchanger outlet temperature goes above 135° F (57° C), and
• the air flow switch (AFS), which senses the pressure drop across the air metering orifice,
• the automatic gas shut-off (AGS) switch, which opens if the heat exchanger outlet temperature goes above 140° F
(60° C).
• the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 480° F (249° C).
The air flow switch (AFS) senses the pressure drop across the air metering orifice. As soon as there is suf ficient air flow,
the AFS closes, closing the circuit to the hot surface igniter (HSI), which ignites the fuel mixture. On a call for heat, the
blower and HSI are energized. In about 20 seconds, the gas valve opens and ignition occurs. The HSI then switches to a
sensing mode and monitors the flame.
The heater is equipped with a digital operating control that enables the user to pre-set the desired pool and spa water
temperatures. The control enables the user to select between pool and spa heating, and features a digital display that
indicates the water temperature.
PUTTING THE HEATER INTO SERVICE
If the heater is installed below the level of the pool, or more than two feet above pool level, the pressure switch setting
should be adjusted. See WATER PRESSURE SWITCH, in the SAFETY CONTROLS Section.
Before putting the heater into service for the first time, follow the instructions under “BEFORE ST AR T -UP” (page 33) in
the front of this manual. Check for proper operation of the heater by following the steps under “OPERATION
INSTRUCTIONS.”
Damage to equipment caused by improper installation or repair will void the warranty.
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Section 3. Installation Instructions
SPECIFICATIONS
These installation instructions are designed for use by qualified personnel only, trained especially for installation of this
type of heating equipment and related components. Some states require installation and repair by licensed personnel. If
this applies in your state, be sure your contractor bears the appropriate license. See Figure 2 for Outdoor and Indoor
Installations.
DIMENSIONS IN INCHES
23.02"
(58.5 cm)
11
16"
(40.6 cm)
28.15"
(71.5 cm)
ELECTRICAL
CONDUIT PORT
32.61"
(82.8 cm)
21.0"
(53.3 cm)
TOPFRONT
EXHAUST SIDE
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
16.0"
(40.6 cm)
22.7"
(57.7 cm)
28.2"
(71.6 cm)
Figure 2.
PLUMBING SIDE
5.6"
(14.2 cm)
10.13"
(25.7 cm)
12
PLUMBING CONNECTIONS
The MasterTemp heater has the unique capability of direct
schedule 40 PVC plumbing connections. A set of bulkhead
fittings is included with the MasterTemp heater to insure
conformity with Pentair’s recommended PVC plumbing
procedure. Other plumbing connections can be used. See
Figure 3 for plumbing connections.
Section 3. Installation Instructions
CAUTION
POOL
HEATER
Before operating the heater on a new installation, turn
on the circulation pump and bleed all the air from the
MANUAL
BY-PASS
TO
POOL
GATE
VALVE
FILTER
PUMP
filter using the air relief valve on top of the filter. Water
should flow freely through the heater. Do not operate
the heater unless water in the pool/spa is at the proper
Figure 3.
FROM
POOL
level. If a manual by-pass is installed, temporarily close it
to insure that all air is purged from the heater.
W A TER CONNECTIONS
The heater requires proper water flow and pressure for its
operation. See Figure 5 for the recommended installation.
The filter pump discharges to the filter , the filter discharges
to the heater, and the heater discharges directly to the pool
or spa.
A manual bypass valve should be installed across the heater
when the pump flow exceeds 120 GPM (454 LPM). See
“WATER FLOW RATE” on page 13- T able 1 for setting of
the manual by-pass valve.
Make sure that the outlet plumbing from the heater contains
Main
Drain
Pool
no shut-off valves or other flow restrictions that could prevent
flow through the heater (except for pool installations as noted
below, or winterizing valves where needed). T
o switch flow
between the pool and spa, use a diverter valve. Do not use
any valve that can shut off the flow.
Install the chemical feeder downstream of the heater. Install
a chemical resistant one-way check valve between the heater
From Pool
3-Way
Valve
and the chemical feeder to prevent back-siphoning through
the heater when the pump is off.
NOTICE: If the heater is plumbed in backwards, it will cycle continuously. Make sure piping from filter is not reversed
when installing heater.
Connect the heater directly to 2" PVC pipe, using the integral unions provided. Heat sinks are not required. The low
thermal mass of the heater will prevent overheating of the piping connected to the pump even if the heater shuts down
unexpectedly.
Occasionally a two-speed pump will not develop enough pressure on the low speed to operate the heater. In this case, run
the pump at high speed only to operate the heater. If this does not solve the problem, do not try to run the heater. Instead,
correct the installation.
Do not operate the heater while an automatic pool cleaner is also operating. If the circulation pump suction is plugged (for
example by leaves), there may not be adequate flow to the heater. Do not rely on the pressure switch in this case.
3-Way
Valve
Heater
Spa
Figure 5.
Chlorinator
Check Valve
Filter
Pump
3-Way
Valve
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Section 3. Installation Instructions
13
VALVES
When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping
system to isolate the equipment from the pool or spa. Check valves are recommended to prevent back-siphoning. Backsiphoning is most likely to occur when the pump stops, creating a pressure-suction differential. Do NOT sanitize the pool
by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high concentration of
chlorine to enter the heater, which could cause corrosion damage to the heat exchanger.
CAUTION
Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters
or pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line
is down stream of the heater, and is equipped with a positive seal noncorrosive “Check Valve”, (P/N R172288),
between the feeder and heater.
MANU AL BY-PASS
Where the water flow rate exceeds the maximum 120 GPM, a manual
Figure 4.
bypass should be installed and adjusted. After installing the valve, adjust
the valve to bring the flow rate within the acceptable range. Then remove
the valve handle or lock it in place to avoid tampering. See Figure 4.
wolfdednemmocermumixamehtdeecxetonoD*
Table 1.
Cool water
Warm water out
1. Set Manual By-Pass Valve.
2. Remove Handle.
Outlet to pool
Inlet to heater
ledoM)MPL()MPG(.niM*)MPL()MPG(.xaM
571)67(02)454(021
002)67(02)454(021
052)59(52)454(021
003)411(03)454(021
004)251(04)454(021
.gnipipgnitcennocehtrofetar
* Pumps 2 HP or larger can produce water pressure
flow in excess of 120 GPM. For these pumps, a
BY-PASS VALVE is recommended.
See page 46 for Pressure Relief Valve Installations.
BELO W POOL LEVEL INST ALLA TION
If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified
service technician. See following CAUTION before installation.
BELOW OR ABOVE POOL INSTALLATION
The water pressure switch is set in the factory at 3.00 PSI (± 0.75 PSI). This setting is for a heater installed at pool level.
If the heater is to be installed more than 1’ above or below, the water pressure switch must be adjusted by a qualified
service technician. See page 35, Figure 29.
If the heater is installed more than 5’ above the pool or more than 4’ below the pool level, you will be beyond the limits
of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet
piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water
pressure switch wires.
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
CAUTION
FLOW SWITCH
14
Section 3. Installation Instructions
GAS CONNECTIONS
GAS LINE INSTALLATIONS
Before installing the gas line, be sure to check which gas the heater has been designed to burn. This is important because
different types of gas require different gas pipe sizes. The rating plate on the heater will indicate which gas the heater is
designed to burn. The Table 2, shown on page 15, show which size pipe is required for the distance from the gas meter to
the heater. The table is for natural gas at a specific gravity of .65 and propane at a specific gravity of 1.55.
When sizing gas lines, calculate three (3) additional feet of straight pipe for every elbow used. When installing the gas line,
avoid getting dirt, grease or other foreign material in the pipe as this may cause damage to the gas valve, which may result
in heater failure.
The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances
that may be used on the same meter. The gas line from the meter will usually be of a larger size than the gas valve
supplied with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction
as close to the heater as possible.
The heater requires a gas supply of not less than 4" (10.2 cm) wc and not more than 14" (35.6 cm) wc. Gas supply
pressures outside of this range may result in improper burner operation. A minimum flowing or dynamic inlet pressure
(while the heater is running) of 4" (10.2cm) wc is required to maintain input rating with no more than a 2” pressure drop
between static and dynamic. The gas supply must be installed in accordance with the National Fuel Gas Code,ANSIZ223.1, or standard CSA B149.1, Natural Gas and Propane Installation Codes, as applicable and all applicable
local codes. Install a manual shut-off valve and a sediment trap and union located outside the heater panels, see Figure 6.
Do not use a restrictive gas cock. The following minimum gas pipe sizes are recommended for natural gas supply piping,
see Table 2 on page 15. For low pressure LP gas, pipe size may be reduced by 1/4", with a minimum pipe size of 1/2".
Check for compliance with local codes.
The heater and any other gas appliances must be disconnected from the gas supply piping system during any pressure
testing on that system, (greater than ½ PSI). The heater and its gas connection must be leak tested before placing the
heater in operation. Do not use flame to test the gas line. Use soapy water or another nonflammable method.
NOTE
A manual main shut-off valv e must be installed externally to the heater.
WARNING
DO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRANTY.
SEDIMENT TRAPS
Install a sediment trap and union located outside the
heater panels in accordance with National code
requirements. Do not use a restrictive gas cock. The
sediment trap shall be either a tee fitting with a capped
nipple in the bottom outlet which can be removed for
cleaning, as illustrated in Figure 6, or an other device
recognized as an effective sediment trap. All gas piping
should be tested after installation in accordance with
local codes.
18–24" of 3/4"
Gas line from
Valve
Union
Sediment
Trap
1" Dia. or larger
(See "Recommended
Pipe Sizes" Chart)
Bell
Reducer
Figure 6.
At least 9"
At least 3"
Manual
Shut-off
Valve
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Before operating the heater, the heater and its gas connections must be leak tested. Do NOT use an open flame to test
for leaks. Test all gas connections for leaks with soapy water or another non-flammable method (see page 14).
The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The heater must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure
testing of the gas supply at test pressures equal to or less than 1/2 psig (3.5 kPa).
CHECKING THE GAS PRESSURE THROUGH THE COMBINATION GAS CONTROL VALVE
WARNING
Risk of fire and explosion. Improper installation, incorrect adjustment, alteration, service, or maintenance of the Combination
Gas Control Valve can lead to fire or explosion, causing loss of life, personal injury, and/or property damage. If it is necessary
to adjust the gas valve, this must be done by only by a qualified service agency. These instructions are for the use of
qualified service technicians only!
This appliance is equipped
with an unconventional gas
control valve that is factory
set with a manifold
pressure of –.2" (–0.5cm)
wc. Installation or service
To Air Flow
Switch
Connection
for Service
To Air Flow
Switch
To Gas
Valv e V ent
To Gas
Valve Vent
must be performed by a
qualified installer, service
agency , or the gas supplier.
If this control valve is
replaced, it must be
replaced with an identical
control.
The combination gas
To Low Side of
Differential Pressure Gauge
Pressure Tap
valve incorporates dual shut-off valves and a negative-pressure regulator. For proper operation, the regulated pressure
at the outlet manifold of the valve must be –0.2" (–0.5cm) wc below the reference pressure at the blower mixer inlet,
and the gas valve ‘VENT’ tap must be connected to the end cap air orifice as shown in Figure 7.
Do not attempt to adjust the gas input by adjusting the regulator setting. The correct gas regulator setting is
required to maintain proper combustion and must NOT be altered.
Ven t
Connection
for Test
To High Side
of Differential
Pressure Gauge
Figure 7.
Pressure Tap
Inlet
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide
16
Section 3. Installation Instructions
CAUTION
The use of Flexible Connectors (FLEX) is NOT recommended unless they are properly sized according to the
supplier recommendations for the heater rating.
For heaters located outdoors, using the built-in stackless venting system.
WARNING
Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not
install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to
determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and
filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum
Gases, ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA B149.2 (latest edition) in Canada. Consult local codes and fire
protection authorities about specific installation restrictions.
Locate the heater on a level surface in an open area that is protected from drainage or run-off. Install the heater in an area
where leaves or other debris will not collect on or around the heater.
T o avoid damage to the electronic components in the heater, take care to prevent prolonged exposure to driving sources
of water (such as lawn sprinklers, heavy roof runoff, hoses, etc.). Avoid operation in persistent, extreme, moist or salty
environments. In extreme weather, shut down the heater and disconnect the power to it until the weather has moderated.
In areas subject to hurricanes or very high winds, purchase the Bolt Down Bracket Kit, P/N 460738.
HEATER CLEARANCES – OUTDOOR
IMPORTANT!
• In an outdoor installation it is important to ensure water is diverted from overhanging eves with a proper
gutter/drainage system. The heater m ust be set on a level foundation f or proper drainage.
• This unit shall not be operated outdoors at temperatures below -20o F.
If the heater is located under a roof overhang, there must be at least three (3) feet (1m) of
clearance between the bottom of the overhang and the top of the heater exhaust vent, see Figure
8. If the heater is under a roof overhang, the space around the heater must be open on three
sides. DO NOT, under any circumstances, install the heater under ANY deck.
For Heater mounting
bolts and clamps,
purchase separately
Bolt Down Bracket Kit,
Part No.
460738.
Lead
Anchor
MASTERTEMP® Pool and Spa Heater Installation and User’s Guide Rev. M 1-8-15
Section 3. Installation Instructions
17
For minimum exhaust vent clearances for all building openings, including but not limited to vented eaves, doors, windows,
gravity air inle t, see Figure 9, show below.
In Canada, the heater must be installed with the top of the vent at least 10 feet (3m) below, or to either side of, any opening
into a building.
Orient the heater for convenient access to the water connections and the gas and electrical connections.
Note: Check local building codes for installing the heater from any property line set back requirements (see the
installation diagram below).
CAUTION
If installing the heater next to or near an air
conditioning unit or a heat pump, allow a
minimum of 36 in. (91.4 cm) between the air
conditioning unit and the heater.
3 ft. (1 M) or more
Building
Figure 9.
6 in
Exhaust Grill
(Vent)
OUTDOOR INSTALLATION
VENTING GUIDELINES
SIDE VIEW
From building wall
Figure 8.
From window or door
3'
4'
4'
Force
Air Inlet
4'
Property Line
Check local building codes
for setback requirements.
Vent T ermination:
Must be at least 3 ft. above any forced
air inlet located within a 10 ft. radius.
Must be located 6 in. away from the building
wall and the following distances away from any building
wall openings, included but not limited to vented eaves,
doors, windows, gravity air inlet:
4 ft. below,
4 ft. horizontally
Rev. M 1-8-15 MASTERTEMP® Pool and Spa Heater Installation and User’s Guide