![](/html/dc/dc05/dc05cea2fa00936cb5a827061f63cdd61003839fc70bcbc1cf761f153d7efac2/bg1.png)
›
Model
Z
›
Unit Size
3 8 101 121
5 81 102 14
6 10 12 15
›
Motor Tap
S = Slow Speed
H = High Speed
›
Enclosure
O = Open Drip Proof
E = Explosion Proof
›
Voltage
A = 110V G = 230V N = 440V
B = 115V H = 240V P = 460V
C = 120V J = 277V Q = 480V
D = 200V K = 380V R = 575V
E = 208V L = 400V S = 600V
F = 220V M = 415V
›
Cycle
5 = 50 Hz 6 = 60 Hz
›
Discharge Orientation
R = Right Angle
T = Top Discharge / Inline
›
Damper
0 = None
D = Ceiling Radiation Damper
›
Curb Cap
C = Curb Mounted
F = Flat Roof
S = Sloped Roof
W = Wall Mount
0 = None
›
Brick Vent
0 = None
B = Brick Vent
Engineering Specifications & Configurations
›
Steel Grille
0 = None
G = Steel Grille
›
Square to Round Transition
0 = None
T = Square to Round Transition
›
Top Discharge
0 = None
T = TDA Kit Factory Installed
F = TDA Field Mount
›
Vibration Isolation
0 = None
RH = Rubber Hanger
›
Transformer*
0 = None
T = Transformer
›
Speed Controller
0 = None
L = Loose
M = Mounted
›
Thermostat
0 = None
›
Air Minder Switch
0 = None
D = Air Minder Time Delay Switch
›
Motion Sensor
0 = None
M = Motion Sensor
›
Pilot Light
0 = None
P = Pilot Light
›
2 Speed Switch
0 = None
* Does not apply to models Z1, ZL1, ZL2
Engineering Specifications
Zephyr
›
Zephyr (Z3 - Z15)
Direct drive ceiling and cabinet fan shall
be Zephyr Z, manufactured by PennBarry,
Richardson, Texas 75081.
Fan housings shall be acoustically
insulated, galvanized steel, and include
integral backdraft damper (except Z1, ZL1,
ZL2) which shall be chatter proof. Grille
face shall be of aerodynamic white egg
crate design and provide 85% free area.
Fans shall be provided with cord, plug,
and receptacle inside the housing. Entire
fan, motor and wheel assembly shall be
removable. Fans shall be available with
TDA panel (except Z1, ZL1, ZL2) for inline
orientation. Units shall be eld convertible
from right angle to top discharge. Fans
shall have forward curved centrifugal
wheel(s). Fan motors shall be multispeed (for applicable models), positively
cooled, have thermal overload protection,
be suitably grounded, and mounted on
vibration isolators.
Each fan shall bear the AMCA Licensed
Rating Seal for Air and Sound Performance
(Z) or Air Performance (Z14/15), and shall
be UL Listed for UL705 and UL507, and
shall be CSA Listed. The Z15 is not UL507
certied.
Ceiling Exhaust Fans
©PENNBARRY 2009
WWW.PENNBARRY.COM
PENNBARRY
Z
e
p
h
y
r
15
![](/html/dc/dc05/dc05cea2fa00936cb5a827061f63cdd61003839fc70bcbc1cf761f153d7efac2/bg2.png)
Engineering Specifications
Zephyr
Engineering Specifications & Configurations
›
›
Model
Z1 ZL1 ZL2 ZJ1 ZT
›
Unit Size
0 = None
›
Drive Type
D = Direct Drive B = Belt Drive
›
Motor Tap
0 = None
›
Enclosure
Ceiling Exhaust Fans
O = Open Drip Proof
›
Voltage
A = 115V
›
Cycle
6 = 60 Hz
›
Discharge Orientation
R = Right Angle
›
Damper*
0 = None
BDD = Backdraft Damper
›
Curb Cap
C = Curb Mounted F = Flat Roof
S = Sloped Roof W = Wall Mount
›
Brick Vent
0 = None B = Brick Vent
›
Steel Grille*
0 = None G = Steel Grille
›
Square to Round Transition*
0 = None
T = Square to Round Transition
›
Top Discharge*
0 = None
T = TDA Kit Factory Installed
F = TDA Field Mount
›
Vibration Isolation
0 = None RH = Rubber Hanger
›
Transformer*
0 = None T = Transformer
›
Speed Controller
0 = None L = Loose M = Mounted
Zephyrette & Zephyr Jr.
All ceiling and/or wall mounted fans indicated on the plans and schedule shall be
Zephyr Jr., or Zephyrette models by PennBarry, 1401 North Plano Road, Richardson,
TX 75081.
Air deliveries and maximum sone levels shall be as indicated on the plans. Fans
shall be listed with Underwriters Laboratories. Fans shall feature true steel centrifugal
wheels and the galvanized steel fan casing shall incorporate an integral backdraft
damper. Motor speed shall not exceed listed RPM. Grille shall be of white egg-crate
shape design, comply with OSHA requirements and provide 85% free open area.
Terminal box shall be provided with cord, plug and receptacle. Entire fan, motor and
wheel assembly shall be removable without disturbing the housing.
Each fan shall be UL705 and UL507 Listed and CSA Listed.
›
Zephyr Transfan
Direct drive axial room-to-room fan shall be Transfan TF, manufactured by PennBarry,
Richardson, Texas 75081.
Fan housing shall be galvanized steel and shall include an adjustable sleeve to
accommodate various wall thicknesses. Two-faced grilles shall be of aerodynamic
white egg crate design and provide 85% free area. Entire fan, motor and propeller
assembly shall be removable. Propellers shall be die formed aluminum. Fan motor
shall be permanently lubricated, positively cooled, & have thermal overload protection.
Fans shall be provided with cord, plug, speed controller and receptacle factory installed
inside the housing.
Each fan shall bear the AMCA Licensed Ratings Seal for Air Performance, & shall be
UL705 and UL507 and CSA Listed.
›
Zephyr Z1, ZL1, & ZL2
Direct drive ceiling and cabinet fan shall be Zephyr, Z1 or Zephyr Light, ZL and supplied
by PennBarry, Richardson, Texas 75081.
Fan housings shall be painted steel and include integral backdraft damper which shall
be chatter proof. Face grille shall be of aerodynamic design and include an unbreakable
lens for use with a 100 watt (max) bulb (except Z1). Fans shall be provided with cord,
plug and receptacle inside the housing. Entire fan, motor and wheel assembly shall
be removable. Fans shall have a forward curved centrifugal wheel. Fan motors shall
be positively cooled, have thermal overload protection, be suitably grounded and
mounted on vibration isolators.
Each fan shall bear the AMCA Licensed Rating Seal for Air and Sound Performance
and shall be UL507 and CSA Listed.
›
Thermostat
0 = None
›
Air Minder Switch
0 = None
Z
D = Air Minder Time Delay Switch
e
›
Motion Sensor
0 = None M = Motion Sensor
p
›
h
Pilot Light
0 = None P = Pilot Light
y
* Does not apply to models Z1, ZL1, ZL2
r
PENNBARRY
16
©PENNBARRY 2009
WWW.PENNBARRY.COM