PennBarry Zephyr User Manual

TM
Model
Z
Unit Size
3 8 101 121 5 81 102 14
6 10 12 15
Motor Tap
S = Slow Speed H = High Speed
Enclosure
O = Open Drip Proof E = Explosion Proof
Voltage
A = 110V G = 230V N = 440V B = 115V H = 240V P = 460V
C = 120V J = 277V Q = 480V
D = 200V K = 380V R = 575V E = 208V L = 400V S = 600V F = 220V M = 415V
Cycle
5 = 50 Hz 6 = 60 Hz
Discharge Orientation
R = Right Angle T = Top Discharge / Inline
Damper
0 = None D = Ceiling Radiation Damper
Curb Cap
C = Curb Mounted F = Flat Roof S = Sloped Roof W = Wall Mount 0 = None
Brick Vent
0 = None B = Brick Vent
Engineering Specifications & Configurations
Steel Grille
0 = None
G = Steel Grille
Square to Round Transition
0 = None T = Square to Round Transition
Top Discharge
0 = None T = TDA Kit Factory Installed F = TDA Field Mount
Vibration Isolation
0 = None RH = Rubber Hanger
Transformer*
0 = None
T = Transformer
Speed Controller
0 = None
L = Loose
M = Mounted
Thermostat
0 = None
Air Minder Switch
0 = None D = Air Minder Time Delay Switch
Motion Sensor
0 = None M = Motion Sensor
Pilot Light
0 = None
P = Pilot Light
2 Speed Switch
0 = None
* Does not apply to models Z1, ZL1, ZL2
Engineering Specifications
Zephyr
Zephyr (Z3 - Z15)
Direct drive ceiling and cabinet fan shall be Zephyr Z, manufactured by PennBarry, Richardson, Texas 75081.
Fan housings shall be acoustically insulated, galvanized steel, and include integral backdraft damper (except Z1, ZL1,
ZL2) which shall be chatter proof. Grille
face shall be of aerodynamic white egg crate design and provide 85% free area. Fans shall be provided with cord, plug, and receptacle inside the housing. Entire fan, motor and wheel assembly shall be removable. Fans shall be available with
TDA panel (except Z1, ZL1, ZL2) for inline
orientation. Units shall be eld convertible from right angle to top discharge. Fans shall have forward curved centrifugal wheel(s). Fan motors shall be multi­speed (for applicable models), positively cooled, have thermal overload protection, be suitably grounded, and mounted on vibration isolators.
Each fan shall bear the AMCA Licensed Rating Seal for Air and Sound Performance (Z) or Air Performance (Z14/15), and shall be UL Listed for UL705 and UL507, and shall be CSA Listed. The Z15 is not UL507 certied.
Ceiling Exhaust Fans
©PENNBARRY 2009
WWW.PENNBARRY.COM
PENNBARRY
Z e p h
y r
15
TM
Engineering Specifications
Zephyr
Engineering Specifications & Configurations
Model
Z1 ZL1 ZL2 ZJ1 ZT
Unit Size
0 = None
Drive Type
D = Direct Drive B = Belt Drive
Motor Tap
0 = None
Enclosure
Ceiling Exhaust Fans
O = Open Drip Proof
Voltage
A = 115V
Cycle
6 = 60 Hz
Discharge Orientation
R = Right Angle
Damper*
0 = None BDD = Backdraft Damper
Curb Cap
C = Curb Mounted F = Flat Roof S = Sloped Roof W = Wall Mount
Brick Vent
0 = None B = Brick Vent
Steel Grille*
0 = None G = Steel Grille
Square to Round Transition*
0 = None T = Square to Round Transition
Top Discharge*
0 = None T = TDA Kit Factory Installed F = TDA Field Mount
Vibration Isolation
0 = None RH = Rubber Hanger
Transformer*
0 = None T = Transformer
Speed Controller
0 = None L = Loose M = Mounted
Zephyrette & Zephyr Jr.
All ceiling and/or wall mounted fans indicated on the plans and schedule shall be Zephyr Jr., or Zephyrette models by PennBarry, 1401 North Plano Road, Richardson,
TX 75081.
Air deliveries and maximum sone levels shall be as indicated on the plans. Fans shall be listed with Underwriters Laboratories. Fans shall feature true steel centrifugal wheels and the galvanized steel fan casing shall incorporate an integral backdraft damper. Motor speed shall not exceed listed RPM. Grille shall be of white egg-crate shape design, comply with OSHA requirements and provide 85% free open area. Terminal box shall be provided with cord, plug and receptacle. Entire fan, motor and wheel assembly shall be removable without disturbing the housing.
Each fan shall be UL705 and UL507 Listed and CSA Listed.
Zephyr Transfan
Direct drive axial room-to-room fan shall be Transfan TF, manufactured by PennBarry, Richardson, Texas 75081.
Fan housing shall be galvanized steel and shall include an adjustable sleeve to accommodate various wall thicknesses. Two-faced grilles shall be of aerodynamic white egg crate design and provide 85% free area. Entire fan, motor and propeller assembly shall be removable. Propellers shall be die formed aluminum. Fan motor shall be permanently lubricated, positively cooled, & have thermal overload protection. Fans shall be provided with cord, plug, speed controller and receptacle factory installed inside the housing.
Each fan shall bear the AMCA Licensed Ratings Seal for Air Performance, & shall be UL705 and UL507 and CSA Listed.
Zephyr Z1, ZL1, & ZL2
Direct drive ceiling and cabinet fan shall be Zephyr, Z1 or Zephyr Light, ZL and supplied by PennBarry, Richardson, Texas 75081.
Fan housings shall be painted steel and include integral backdraft damper which shall be chatter proof. Face grille shall be of aerodynamic design and include an unbreakable lens for use with a 100 watt (max) bulb (except Z1). Fans shall be provided with cord, plug and receptacle inside the housing. Entire fan, motor and wheel assembly shall be removable. Fans shall have a forward curved centrifugal wheel. Fan motors shall be positively cooled, have thermal overload protection, be suitably grounded and mounted on vibration isolators.
Each fan shall bear the AMCA Licensed Rating Seal for Air and Sound Performance and shall be UL507 and CSA Listed.
Thermostat
0 = None
Air Minder Switch
0 = None
Z
D = Air Minder Time Delay Switch
Motion Sensor
0 = None M = Motion Sensor
p
Pilot Light
0 = None P = Pilot Light
y
* Does not apply to models Z1, ZL1, ZL2
r
PENNBARRY
16
©PENNBARRY 2009