Pelican WF6, WF10 Owner’s Manual

Owner’s Manual
Pelican WF6/WF10 Iron/Manganese
Filter & Salt Free Softener
Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener
Rev T
Page 2
© Copyright 2019 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems. Pelican Water Systems makes
no warranty of any kind with regard to this material, including, but not limited to, the implied warr anties of merchantability and fitness for a particular purpose. Pelican Water Systems shall not be liable for technical or editorial errors or omissions contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The information is provided “as is” without warranty of any kind and is subject to change without notice. This document contains proprietary information which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Pelican Water Systems. Pelican Water Systems is an Enviro Water Solutions, Inc. company.
© 2019 Enviro Water Solutions, Inc. 306
0 Performance Circle, Suite 2, DeLand, FL 3272 4
(877) 842-1635
Rev T
Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener
Page 3
Table of Contents
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Operation and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Important Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Water Conditions for Ope ration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Complete Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Overview Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Bypass Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Carbon Soak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Carbon Flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sediment Filter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sediment Filter Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chemical Injector Pump and Solution Tank Installation . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chemical Injector Pump Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Solution Tank Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Iron and Manganese Tank Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Whole House Water Filter Tank Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Whole House Salt Free Water Softener/Conditioner Tank Installation . . . . . . . . . . . . . . . . 19
NaturSoft - Media Soak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NaturSoft - Media Flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Complete the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Programming the Electronic Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Step 1: Setting the Date & Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Step 2: Performing Manual Regeneration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Testing Chlorine Levels in Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Flush your Hot Water Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
What to Expect with your New Salt Free Water Softener/Conditioner . . . . . . . . . . . . . . . 24
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Replacing the Sediment Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Chemical Injector Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Solution Tank Refill — Chlorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Warranty Registration Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
© 2019 Enviro Water Solutions, Inc. 306
0 Performance Circle, Suite 2, DeLand, FL 3272 4
(877) 842-1635
Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
CAUTION:
Product Operation and Specifications
Specification Description WF6 WF10
Rev T
Page 4
Max Flow Rate
Minimum Working Pressure 25 PSI Maximum Working Pressure 80 PSI Maximum Vacuum 5 inch/127 mm Hg Operating Temperatures 36°F – 100°F pH Range 7 - 11
10 GPM 15 GPM
Important Information
Read these instructions carefully and determine the location of all system components before
beginning installation.
Check all applicable plumbing, building, and electrical codes for installation compliance.Install the system on the main water supply.Systems that contain electronic components cannot be installed outside in uncovered areas.
Water Conditions for Operation
The water should be free of hydrogen sulfide, a dissolved gas with a characteristic smell of rotten
eggs. If present, it can coat the catalytic surface of the media and interfere with the process. The gas should be removed through adequate pre-treatment.
The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic
surface of the media and interfere with the process. Remove through adequate pre-treatment.
The water should contain less than 1 mg/l of phosphates. Phosphates sequester dissolved hardness
molecules preventing them from forming crystals and may coat the catalytic media surface and interfere with the process.
The copper level in the water supply should be below the MCL of 1.3mg/L. If copper is present above
this level, it can attach to the surface of the catalytic media and interfere with the process.
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic components of the system will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing. Some homes may have been built in accordance with building codes, which actually encouraged the grounding of electrical appliances through the plumbing system. Consequently, the installation of a bypass consisting of the same material as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re­establishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use.
When adding a filtration/softening system to homes/buildings supplied by well water, the syst em should be installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic
applications. If you are using a booster pump, then install this system following the booster
pump. If you have questions, please call customer service.
© 2019 Enviro Water Solutions, Inc. 3060 Performance Circle, Suite 2, DeLand, F L 32 72 4
WARNING:
(877) 842-1635
Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
Page 5
Complete Parts List
Note: Pelican supplies the parts below to accommodate a variety of water supply lines.
Table 1: Parts List
Part Description Qty. Part Description Qty.
Rev T
1" Plastic Male NPT Assembly:
V3007-04 WS1 Fitting 1"
2 Bypass Valve:
In/Out Bypass Valve with Red
Arrow Handles Plastic Male NPT Assembly (2): O-Rings (2), Split Rings (2), and Connectors (2)
1" PVC Tail Adaptor for
2 Hose Bib Assembly 1
Electronic Head Bypass
90 degree 1" PVC Tail Adaptors also included
Sediment Filter System:
Big Blue Filter Housing, Mounting Bracket, Phillips Head Screws (4), Bolt Head
1 Bypass Valve for
Electronic Head
Bypass Allen Wrench Included
Screws (4), and Washers (4)
Sediment Filter:
1 Sediment Filter Wrench 1
5 Micron Poly-Spun Sediment Filter
Electronic Head 1 Solution Tank 1
2
1
M EN U
SE T
PVC Tubing Drain Line
1 Chemical Injector Pump
(50 ft.)
Chlorine Test Strips 1 Chemical Injector Pump 1
Non-Abrasive Auto Wax 1
Rinse-Aid
1
© 2019 Enviro Water Solutions, Inc. 3060 Performance Circle, Suite 2, DeLand, F L 32 72 4
1
Tubing
(2) 1" Bushings Included
(877) 842-1635
Rev T
Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
Part Description Qty. Part Description Qty.
Page 6
Pelican Whole House Water Filter
Pelican Salt Free Water Softener/Conditioner
1 Pelican Whole House Iron
1
Note: Drawings are not to scale. Additional fittings will be needed to adapt to your plumbing.
1
& Manganese Filter
© 2019 Enviro Water Solutions, Inc. 3060 Performance Circle, Suite 2, DeLand, F L 32 72 4
(877) 842-1635
Installa
tion Overview Diagram
Rev T
7
Page
WF 6/10
**
BYPASS
HOSE SPIGOTS
NATURSOFT
WATER
FILTER
SET
MENU
IRON
FILTER
MANGANESE
TANK
SOLUTION
INSTALLATION OVERVIEW
°
MAX PRESSURE OPERATING: 80 PSI
MAX TEMPERATURE: 120
CONNECTION SIZE: 1"
DO NOT SCALE DRAWING





0
0
INJECTION PUMP
0
0
SEDIMENT FILTER
SHUT OFF VALVES
5


 
  
  
Water Systems
Pelican
P
**BACKWASH LINE TO BE PLUMBED TO A DRAIN
Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
Installation Overview
Wall Wall
Rev T
Page 8
IN
Incoming
Water
Supply
Sediment Filter
OUT
Solution Tank
Electronic
Head
Figure 1
Pre-Installation
Bypass Valve Installation
Chemical Injector
Pump
Drain Line
Barb
Whole House
Iron & Manganese Filter
INLET
Whole House
Water Filter
INLET
OUTLET
Salt Free Water
Softener/Conditioner
Spigot
Outgoing
Water to
House
OUTLET
Red Arrow
Quick
Connect Nut
Water Filter
Head
INLET
OUTLET
Whole House Water Filter &
Salt Free Water Softener/Conditioner
Bypass
Valve
Electronic
Head
Whole House
Iron & Manganese Filter
Front View
Red
Clip
Figure 2
Whole House Water Filter & Salt Free Water Softener/Conditioner - The Bypass Valv e comes pre­assembled and ready to install with the O-Rings, Split Rings, and Quick Connect Nuts. Push the Bypass Valve into the head of the Pelican Whole House Water Filter or Salt Free Water Softener/Conditioner with the unthreaded ends orientated towards the tank and hand-tighten the Quick Connect Nuts.
Whole House Iron & Manganese Filter - If the Red Clips are in the slots (female opening of Electronic Head) remove them. Push the male O-Ring side of the Bypass Valve into the female opening of the Electronic Head. Push the Red Clips back into the slots to tighten.
© 2019 Enviro Water Solutions, Inc. 3060 Performance Circle, Suite 2, DeLand, F L 32 72 4
(877) 842-1635
Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener
Bypass Operation
Rev T
Page
SERVICE
BYPASS
Bypass Allen Wrench
Notice:
The Bypass Valve on the Electronic Head can be set to Bypass or Service by turning the knobs on the top of the valve. The valves can be difficult to turn by hand until the seals become saturated. Use the
supplied Bypass Allen Wrench to turn the knobs if necessary.
Note: The Red Arrows on the Whole House Carbon Filter Bypass may be pointing in a different direction then shown. If this is the case, remove the Red Arrows by pulling them straight up. Turn them around and reposition correctly onto the Bypass Valve so they are positioned as shown in the service posistion below.
The Bypass Valve on the Whole House Water Filter can be set to Bypass or Service by turning the Red Arrows on the top of the valve.
In Service
Figure A
In Bypass
Figure B
© 2019 Enviro Water Solutions, Inc. 3060 Performance Circle, Suite 2, DeLand, FL 32724
www.pelicanwater.com
(877) 842-1635
Loading...