Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
CAUTION:
Product Operation and Specifications
Specification DescriptionWF6WF10
Rev T
Page 4
Max Flow Rate
Minimum Working Pressure25 PSI
Maximum Working Pressure80 PSI
Maximum Vacuum5 inch/127 mm Hg
Operating Temperatures36°F – 100°F
pH Range7 - 11
10 GPM 15 GPM
Important Information
Read these instructions carefully and determine the location of all system components before
beginning installation.
Check all applicable plumbing, building, and electrical codes for installation compliance.
Install the system on the main water supply.
Systems that contain electronic components cannot be installed outside in uncovered areas.
Water Conditions for Operation
The water should be free of hydrogen sulfide, a dissolved gas with a characteristic smell of rotten
eggs. If present, it can coat the catalytic surface of the media and interfere with the process. The gas
should be removed through adequate pre-treatment.
The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic
surface of the media and interfere with the process. Remove through adequate pre-treatment.
The water should contain less than 1 mg/l of phosphates. Phosphates sequester dissolved hardness
molecules preventing them from forming crystals and may coat the catalytic media surface and
interfere with the process.
The copper level in the water supply should be below the MCL of 1.3mg/L. If copper is present above
this level, it can attach to the surface of the catalytic media and interfere with the process.
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or
galvanized metal, the plastic components of the system will interrupt the continuity of the
plumbing system. As a result any errant electricity from improperly grounded appliances
downstream or potential galvanic activity in the plumbing system can no longer ground
through contiguous metal plumbing. Some homes may have been built in accordance with
building codes, which actually encouraged the grounding of electrical appliances through the
plumbing system. Consequently, the installation of a bypass consisting of the same material
as the existing plumbing, or a grounded "jumper wire" bridging the equipment and reestablishing the contiguous conductive nature of the plumbing system must be installed prior
to your systems use.
When adding a filtration/softening system to homes/buildings supplied by well water, the syst em should be
installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic
applications. If you are using a booster pump, then install this system following the booster
pump. If you have questions, please call customer service.
Pelican WF6/WF10 Iron/Manganese Filter an d Salt Free Softener
Installation Overview
WallWall
Rev T
Page 8
IN
Incoming
Water
Supply
Sediment Filter
OUT
Solution Tank
Electronic
Head
Figure 1
Pre-Installation
Bypass Valve Installation
Chemical Injector
Pump
Drain Line
Barb
Whole House
Iron & Manganese Filter
INLET
Whole House
Water Filter
INLET
OUTLET
Salt Free Water
Softener/Conditioner
Spigot
Outgoing
Water to
House
OUTLET
Red Arrow
Quick
Connect Nut
Water Filter
Head
INLET
OUTLET
Whole House Water Filter &
Salt Free Water Softener/Conditioner
Bypass
Valve
Electronic
Head
Whole House
Iron & Manganese Filter
Front View
Red
Clip
Figure 2
Whole House Water Filter & Salt Free Water Softener/Conditioner - The Bypass Valv e comes preassembled and ready to install with the O-Rings, Split Rings, and Quick Connect Nuts. Push the Bypass
Valve into the head of the Pelican Whole House Water Filter or Salt Free Water Softener/Conditioner with
the unthreaded ends orientated towards the tank and hand-tighten the Quick Connect Nuts.
Whole HouseIron&Manganese Filter - If theRed Clips are in the slots (female opening of Electronic
Head) remove them. Push the male O-Ring side of the Bypass Valve into the female opening of the
Electronic Head. Push the Red Clips back into the slots to tighten.
Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener
Bypass Operation
Rev T
Page
SERVICE
BYPASS
Bypass Allen Wrench
Notice:
The Bypass Valve on the Electronic Head can be set to Bypass or Service by turning the knobs on the
top of the valve. The valves can be difficult to turn by hand until the seals become saturated. Use the
supplied Bypass Allen Wrench to turn the knobs if necessary.
Note: The Red Arrows on the Whole House Carbon Filter Bypass may be pointing in a different direction
then shown. If this is the case, remove the Red Arrows by pulling them straight up. Turn them around
and reposition correctly onto the Bypass Valve so they are positioned as shown in the service posistion
below.
The Bypass Valve on the Whole House Water Filter can be set to Bypass or Service by turning the Red
Arrows on the top of the valve.