SS4718/SS4718L/SS4722/SS4722L
Sun Shroud and
TI47 Thermal Insulation
Installation/Operation Manual
C1409M-C (7/98)
1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be
observed.
1. Installation and servicing should only be done by qualified service personnel
and conform to all local codes.
2. Only use replacement parts recommended by Pelco.
Please thoroughly familiarize yourself with the information in this manual prior to
installation and operation.
2.0 DESCRIPTION The information contained within this manual covers the SS4718, SS4722, SS4718L,
SS4722L Sun Shrouds and the TI47 Thermal Insulation Kit installation.
The SS4718, SS4722, SS4718L, and SS4722L Sun Shrouds provide an air space
between the sun shroud and the enclosure to protect the enclosure from the direct
rays of the sun and reduce the internal temperature by approximately 10 to 15°F
(-12.2° to -9.4°C).
The TI47 Thermal Insulation Kit provides an improved resistance to heat loss through
the body of the enclosure by adding a 1/4-inch thick polyurethane insulation to the
majority of the internal surfaces.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
3.0 INSTALLATION
3.1 SS4718/SS4722/ The sun shroud is supplied with two (2) threaded spacers and two (2) Phillips head
SS4718L/SS4722L screws.
SUN SHROUDS
To install the sun shroud, perform the following steps (refer to Figure 1).
1. Unlatch and raise enclosure lid.
2. Remove the two (2) screws, nylon washers, nuts and lock washers from the lid
of the enclosure.
3. Attach the threaded spacers to the under side of the sun shroud with the two
(2) screws and nylon washers previously removed, threading them through
the top of the sun shroud.
4. Align the spacers in the sun shroud with the holes in the enclosure lid. Attach
the sun shroud to the enclosure lid with the remaining lock washers and screws.
Tighten screws securely.
3.2 TI47 THERMAL The TI47 thermal insulation sheets are designed to be used with both 18-inch
INSULATION (45.72 cm) and 22-inch (55.88 cm) EH4700 Series enclosures. If insulation is
required for an 18-inch enclosure, the insulation must be cut along the factory-
NOTE:
The camera mounting sled
must be removed for proper installa-
marked perforation. For 22-inch installations, no trimming is necessary. To install
the thermal insulation, perform the following steps:
tion of the thermal insulation, therefore, it should be done prior to the
enclosure installation.
3.2.1 Lid Insulation 1. Unlatch the enclosure lid and raise.
Installation
2. Pop the gas spring off of the lid at the ball-joint connection. Make sure the lid is
supported and not allowed to lay completely open - doing so will damage the
lid hinge.
3. Remove the adhesive backing from the “lid” insulation pad (see Figure 2).
4. Position the insulation around the sun shroud fasteners on the inside of the lid. It
may help to hold the insulation in a folder manner while positioning. Remove the
necessary punch-out holes in the insulation to accommodate the fasteners.
Figure 2. Lid Insulation InstallationFigure 1. Sun Shroud Installation