Documents Affected C1311M-C ExSite IP Series Explosionproof PTZ and Fixed Systems Operation Manual
C2950M-G IX Series Network Camera Installation/Operation Manual
C2953M-G IXE Series Extended Platform Network Camera Installation/Operation Manual
C2962M-E ID Series Network Dome Camera Installation/Operation Manual
C2963M-E IDE Series Network Dome Camera Installation/Operation Manual
C2970M-D IE Series Network Dome Camera Installation/Operation Manual
C2971M-D IEE Series Network Dome Camera Installation/Operation Manual
C2973M-F IM Series Network Dome Camera Installation/Operation Manual
C2982M-A IM-E/IM-V Series Network Dome Camera Installation/Operation Manual
C2990M-A IXE10LW Series Extended Platform Network Camera Installation/Operation Manual
C2992M-A IXSOLW Network Camera Installation/Operation Manual
C2995M-A IMLW Series Network Dome Camera Installation/Operation Manual
C2996M-A IMLW-E/IMLW-V Series Network Dome Camera Installation/Operation Manual
C3469M-C Spectra IV IP Series SD4E Dome System Operation Manual
C3470M-B Spectra HD Series Dome System Installation/Operation Manual
Document Update This addendum provides an explanation of features added in the Sarix 1.8.2 firmware release.
Customizing the Appearance of the Text Overlay
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Set the Text Overlay settings:
Date/Time Overlay: Select Show to display the date and time in the live view overlay. The default setting is Hide.
Camera Name Overlay: Select Show to display the device name in the live view overlay. The default setting is Hide.
4. (Optional) Select the display position for the overlay from the Position drop-down menu. Selections include Top Right, Top Center, Top Left, Bottom
Right, Bottom Center, and Bottom Left.
5. (Optional) Select the format in which the date and time will appear from the Overlay Format drop-down field if you have opted to show the
Date/Time Overlay.
Authentication Mode
Authentication Mode settings determine whether or not viewing video and accessing the camera API requires user authentication.
Open Authentication: Allows users to view video and use the camera API without validating user credentials. With Open Authentication selected, you can
select “Require password for PTZ” to limit PTZ control to authenticated users.
Closed Authentication: Requires users to possess valid credentials to view video and access the camera API. Before selecting Closed Authentication,
ensure that your video management system supports Closed Authentication mode.
CONFIGURING AUTHENTICATION MODE
1. Select Open Authentication or Closed Authentication.
2. (Optional) Select “Require password for PTZ” control to require user authentication for PTZ control even if Open Authentication is selected.
NOTE: Ensure that your video management system supports closed authentication before selecting Closed Authentication.
User and Group Management
Sarix cameras support two methods for managing the permissions of users and groups.
Local Mode: The camera manages users and groups locally. This is the default setting.
Remote Mode: The camera authenticates and manages users through an LDAP server supported by Microsoft
administrators to tie cameras and group permissions into existing single sign-on services (SSO). Selecting Remote Mode disables local user
management settings.
ENABLING REMOTE MODE
1. Click the Users tab.
2. Select Remote Mode under User and Group Management.
3. Type the IP address or hostname of the LDAP server in the LDAP Server box.
4. Type the port over which the camera will communicate with the LDAP server in the LDAP Port box. The default port for LDAP Communications is 389.
5. Type the distinguished name (DN) that is the basis for LDAP searches in the Base DN box.
6. Provide the template to format the username (provided when the user logs on to the camera) for searches in the LDAP directory in the
Bind DN Template box.
7. Provide the LDAP search query for users found in the base DN in the Search Template box. The search must match an entry in the LDAP user record to
the bind name (username).
8. Input Group Mappings for each of the camera’s four user groups:
a.Input the common name (CN) and DN for the group of users to whom you want to grant admin access in the Admins box.
b.Input the CN and DN for the group of users to whom you want to grant manager access in the Managers box.
c.Input the CN and DN for the group of users to whom you want to grant operator access in the Operators box.
d.Input the CN and DN for the group of users to whom you want to grant viewer access in the Viewers box.
9. In the User and Password boxes, input the credentials of a user who can be authenticated through the LDAP server.
NOTE: Remote Mode (LDAP authentication) will not be enabled if you leave these fields blank or do not provide valid credentials; this ensures that you
cannot lock yourself out of the camera with invalid or incorrect LDAP settings.
10. Click Save.
®
Active Directory®. This allows
2C3484M (7/12)
Port Settings
Port settings appear under the System Settings heading in the General Settings section of the Network tab. These settings determine the ports over which
the camera communicates for HTTP, HTTPS, and RTSP protocols. Contact your network administrator before changing port settings to ensure that your port
settings do not conflict with your network infrastructure.
SETTING THE HTTP PORT
NOTE: The HTTP port number must remain at the default setting (80) when connecting to a Pelco video management system (VMS) platform. If connecting
to a Pelco VMS, do not change the HTTP port setting.
1. Place your mouse cursor over the Network tab.
2. Select General from the drop-down menu.
3. Type the new port number in the HTTP Port field. The default port for HTTP communications is 80.
4. Click Save. If you have changed the setting in error, you can click reset to revert to the previously saved setting.
SETTING THE HTTPS PORT
NOTE: The HTTPS port is not configurable unless you have set SSL Mode to Optional or Required and installed a security certificate.
1. Place the mouse cursor over the Network tab.
2. Click General from the drop-down menu.
3. Type the new port number in the HTTPS Port field. The default port for HTTPS communications is 443.
4. Click Save. If you have changed the setting in error, you can click reset to revert to the previously saved setting.
SETTING THE RTSP PORT
1. Place the mouse cursor over the Network tab.
2. Click General from the drop-down menu.
3. Type the new port number in the RTSP Port field. The default port for RTSP communications is 554.
4. Click Save. If you have changed the setting in error, you can click reset to revert to the previously saved setting.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
SOME PELCO EQUIPMENT CONTAINS, AND THE SOFTWARE ENABLES, AUDIO/VISUAL AND RECORDING CAPABILITIES, THE IMPROPER USE OF
WHICH MAY SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES. APPLICABLE LAWS REGARDING THE USE OF SUCH CAPABILITIES VARY
BETWEEN JURISDICTIONS AND MAY REQUIRE, AMONG OTHER THINGS, EXPRESS WRITTEN CONSENT FROM RECORDED SUBJECTS. YOU
ARE SOLELY RESPONSIBLE FOR INSURING STRICT COMPLIANCE WITH SUCH LAWS AND FOR STRICT ADHERENCE TO ANY/ALL RIGHTS OF
PRIVACY AND PERSONALTY. USE OF THIS EQUIPMENT AND/OR SOFTWARE FOR ILLEGAL SURVEILLANCE OR MONITORING SHALL BE DEEMED
UNAUTHORIZED USE IN VIOLATION OF THE END USER SOFTWARE AGREEMENT AND RESULT IN THE IMMEDIATE TERMINATION OF YOUR
LICENSE RIGHTS THEREUNDER.
REGULATORY NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.” This
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this
equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
VIDEO QUALITY CAUTION
FRAME RATE NOTICE REGARDING USER-SELECTED OPTIONS
Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality
modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored. The picture
quality can be degraded by either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced resolution
may result in an image that is less clear or even indiscernible. A picture degraded by reducing the picture rate has fewer frames per second,
which can result in images that appear to jump or move more quickly than normal during playback. Lower frame rates may result in a key event
not being recorded by the system.
Judgment as to the suitability of the products for users’ purposes is solely the users’ responsibility. Users shall determine the suitability of the
products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in
a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.
OPEN SOURCE SOFTWARE NOTICE
This product includes certain open source or other software originated from third parties that is subject to the GNU General Public License (GPL),
GNU Library/Lesser General Public License (LGPL) and different and/or additional copyright licenses, disclaimers, and notices.
The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer to the exact terms of the GPL and LGPL
at http://www.fsf.org (Free Software Fou ndation) or http://www.opensource.org (Open Source Initiative ) regarding your rights under said license.
You may obtain a complete corresponding machine-readable copy of the source code of such software under the GPL or LGPL by sending your
request to digitalsupport@pelco.com; the subject line should read Source Code Request. You will then receive an email with a link for you to
download the source code.
This offer is valid for a period of three (3) years from the date of the distribution of this product by Pelco.
4C3469M-C (4/12)
Description
The Spectra® IV IP Series SD4E dome system was designed with ease of installation and ease of maintenance in mind. Each IP dome system
consists of a back box, a dome drive, and a lower dome. Back box options include the following models: environmental in-ceiling (ideal for
outdoor soffits), indoor in-ceiling, standard and environmental pendant, heavy duty, and stainless steel.
The IP dome system features open architecture connectivity to third-party software. Pelco offers an application programming interface (API) and
software development kit (SDK) that enables third-party systems to interface with Pelco's IP cameras. The camera is also compatible with
®
, DX Series, and Digital Sentry® systems to record, manage, configure, and view multiple live streams.
Endura
This manual explains how to interface with the Spectra IV IP Series SD4E using Internet Explorer
COMPATIBLE SYSTEMS
The camera can also be used with an Endura, DX Series, or Digital Sentry system. It also works with many third-party systems with Pelco’s API
and the ONVIF API. For detailed instructions on configuring the camera using one of these systems, refer to the manual shipped with the system.
Go to partnerfirst.pelco.com for a list of compatible products and partners.
GETTING STARTED
You will need to install your Spectra IV IP Series SD4E dome system before using this manual (refer to the Spectra IV IP Series SD4E Dome
System Installation manual). Once installed, apply power to the system. The system will complete a configuration sequence.
®
or Firefox®.
C3469M-C (4/12)5
Operation
MINIMUM SYSTEM REQUIREMENTS
Network and processor bandwidth limitations might cause the video stream to pause or appear pixilated when additional Web-interface users
connect to the camera. Decrease the images per second (ips), resolution, compression, or bit rate settings of the Web interface video streams to
compensate for network/processor limitations.
Processor: Intel
Operating system: Microsoft
Memory: 512 MB RAM
Network interface card: 100 megabits (or greater)
Monitor: Minimum of 1024 x 768 resolution, 16- or 32-bit pixel color resolution
Web browser: Internet Explorer
Media player: Pelco Media Player or QuickTime
Mac OS X 10.4 (or later)
NOTES:
•Pelco Media Player is recommended for control, smoothness, and reduced latency as compared to QuickTime.
•This product is not compatible with QuickTime version 7.6.4 for Windows XP or Windows Vista. If you have this version installed on your PC,
you will need to upgrade to QuickTime version 7.6.5.
®
Pentium® 4 microprocessor, 1.6 GHz
®
Windows® XP, Windows Vista®, Windows 7® or Mac® OS X 10.4
®
7.0 (or later) or Mozilla® Firefox® 3.0 (or later)
®
7.6.5 for Windows XP, Windows Vista, and Windows 7; or QuickTime 7.6.4 for
ACCESSING THE IP DEVICE
The first time you access the device, the live video page appears. By default, you are viewing the video as a public user and only have access to
the single stream live view.
If, for security purposes, users should not be allowed to view video without first logging on to the camera, change the permissions for public
users.
LOGGING ON TO THE DEVICE
1. Open the Web browser.
2. Type the device’s IP address in the browser address bar.
NOTE: If you do not know the camera’s IP address, you can locate it using the Pelco Device Utility software.
3. Click the Login button in the navigation bar; a dialog box appears.
4. Type your user ID and password.
NOTE: If you are logging on to the camera as the administrator for the first time, the default User ID and Password are admin
(all lowercase). For security purposes, be sure to change the password after you log on for the first time.
5. Click Log In.
Refer to the following section for more information:
•Editing a User on page 26
6C3469M-C (4/12)
Live Video Page
The live video page allows you to manage the way you view live video and capture images. You can also view live video from this page and
access menus on the navigation bar (based on user permissions).
NOTE: The PTZ controls are viewable only after you have logged on to the device.
Refer to the following sections for more information:
•Live Video Page Icons on page 7
•Selecting a Stream on page 9
•Taking a Snapshot on page 10
•Displaying Video in the Multiscreen View on page 10
LIVE VIDEO PAGE ICONS
Viewable icons are based on user permissions.
Select Stream: Selects the viewable video stream that is displayed in live view (primary or secondary) and selects unicast or multicast
settings.
Maximize Viewing Area: Scales the image to the full size of the browser. To resize the video pane to normal view, click the
Show Toolbar button in the upper-right corner of the window.
Show Toolbar: Returns the window to normal view. This option is only available after the window has been set to maximize the
viewing area.
Open Stream in New Window: Opens the video in a scalable, independent window. Opening the video in a separate window allows
you to view the video while other applications are running. This window can be minimized, maximized, or closed using the title bar
buttons of the active window. The window can also be resized by dragging the lower-right corner of the window.
Take a Snapshot: Captures the image displayed in the video pane and then saves it as a JPEG file.
Center Viewing Area*: Centers the camera on an area in the video pane. To center a viewing area, click the desired location in the
video pane.
Pan and Tilt*: Controls the pan and tilt functions. Click and drag the mouse to the left or right to pan the camera. Click and drag the
mouse up or down to tilt the camera.
Resize Viewing Area*: Zooms in on an area of interest. Click and drag the mouse over the view pane to zoom in on an object.
®
*These icons are always available when using the Pelco Media Player. If you are using QuickTime
QuickView Stream is selected.
, these icons are available only when the
C3469M-C (4/12)7
PTZ CONTROLS
NOTE: The PTZ controls are viewable only after you have logged on to the device.
Zoom In: Click and hold the button to zoom the lens in.
Zoom Out: Click and hold the button to zoom the lens out.
Tilt Up: Click and hold the button to tilt the camera up.
Tilt Down: Click and hold the button to tilt the camera down.
Pan Left: Click and hold the button to pan the camera left.
Pan Right: Click and hold the button to pan the camera right.
Focus Near: Click and hold the button to focus on an object near the camera.
Focus Far: Click and hold the button to focus on an object far away from the camera.
Iris Close: Click and hold the button to close the iris and darken the image.
Iris Open: Click and hold the button to open the iris and lighten the image.
KEYBOARD SHORTCUTS
Several keyboard shortcuts are available when viewing live video from Microsoft® Internet Explorer® and the Pelco Media Player. These
keyboard shortcuts display different overlays on a video pane and provide quick access to a specific function.
Keyboard ShortcutFunction
SHIFT + SDisplays details about the live video such as image rate, resolution, and transmission rate.
SHIFT + TDisplays the current date and time.
These keyboard shortcuts are not available when viewing video with Apple
Table A. Keyboard Shortcuts
®
Quicktime®.
8C3469M-C (4/12)
Loading...
+ 24 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.