Pelco PXM100, CMXM100, PAXM100 User Manual

ExSite
Series Mounts WXM100, CMXM100, PAXM100, and PXM100
INSTALLATION
C2216M (5/05)
WXM100
C2216M (5/05) 3
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Only use attachments/accessories specified by the manufacturer.
6. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
7. Installation should be done only by qualified personnel and conform to all local codes.
8. Use only installation methods and materials capable of supporting four times the maximum specified load.
9. Use stainless steel hardware to fasten the mount to outdoor surfaces.
CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any
servicing other that contained in the operating instructions unless you are qualified to do so.
10. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
WARNING: This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
4 C2216M (5/05)
Description
This manual contains the installation instructions for the following ExSite
Series mounts:
WXM100 Wall mount designed to mount the ExSite
Series system directly to a load-bearing vertical surface.
CMXM100 Corner adapter for use with the WXM100 to mount an ExSite Series system to the corner of a structure.
PAXM100 Pole adapter for use with the WXM100 to mount a system to a horizontal pole.
PXM100 Pedestal mount designed to mount an ExSite Series system directly to a horizontal surface in either an upright or inverted
position.
*Recommended strength of concrete is 3,600 psi or 25 Mpa.
**Minimum of 1/8-inch wall.
Model Supplied Hardware Mounting Surface Recommended Hardware
WXM100 None
Solid Concrete*
Five 3/8-16 x 1-9/16-inch long stainless steel drop-in anchors and five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers
Steel I Beam**
Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers and 3/8-16 stainless steel nuts
CMXM100
Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with lock washers to attach the adapter to the WXM100 wall mount
Solid Concrete*
Six 1/2-13 x 2-inch stainless steel drop-in anchors and six 1/2-13 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers
Steel I Beam**
Six 1/2-13 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers and 1/2-13 stainless steel nuts
PAXM100
Four 5/8-inch wide x 40-inch (101.6 cm) long stainless steel straps to attach the adapter to a pole
Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with lock washers to attach the adapter to the WXM100 wall mount
Steel pole with a diameter between 4 and 9 inches (10.16 to 22.86 cm)
Supplied
PXM100 None
Solid Concrete*
Five 3/8-16 x 1-9/16-inch long stainless steel drop-in anchors and five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers
Steel I Beam**
Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers and 3/8-16 stainless steel nuts