Pelco O-I-PCB, HK57-1, WD57-2, WD57-1 User Manual

®
00972
BK57 Blower, HK57
Heater, O/I-PCB and WD57 Defroster Kits for EH5700/EH5700L
Series Environmental
Enclosures
Installation/
Operation Manual
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120

CONTENTS

Section Page
1.0 GENERAL .................................................................................................. 3
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3
2.0 DESCRIPTION .......................................................................................... 4
2.1 CERTIFICATIONS ............................................................................. 4
3.0 BLOWER KIT INSTALLATION ................................................................... 5
4.0 HEATER KIT INSTALLATION ....................................................................9
5.0 DEFROSTER KIT INSTALLATION ............................................................11
6.0 CIRCUIT BOARD KIT INSTALLATION ..................................................... 13
7.0 OPERATION .............................................................................................17
8.0 CARE AND MAINTENANCE .................................................................... 17
8.1 TROUBLESHOOTING ......................................................................17
9.0 WARRANTY AND RETURN INFORMATION ........................................... 20

LIST OF ILLUSTRATIONS

Figure Page
1 Exploded Assembly Diagram for Blower ............................................ 8
2 Exploded Assembly Diagram for Heaters .........................................10
3 Exploded Assembly Diagram for Defroster ....................................... 12
4 Exploded Assembly Diagram for Circuit Board .................................14
5 Input Wiring Diagram ........................................................................ 16
6Wiring Diagram for Optional Circuit Board (O/I-PCB) ....................... 18
7 Circuit Board Component Locations ................................................. 19
8 Circuit Board Layout of Traces .......................................................... 19

LIST OF TABLES

Table Page
A 24 VAC Wiring Distances ...................................................................6
B Exploded Assembly Parts List for Blower .......................................... 8
C Exploded Assembly Parts List for Heaters........................................ 10
D Exploded Assembly Parts List for Defroster ..................................... 12
E Exploded Assembly Parts List for Circuit Board ............................... 14
REVISION HISTORY
Manual # Date Comments
C1423M 6/95 Original manual.
C1423M-A 4/96 Rev. A. Incorporated Manual C1424M for blower kits.
5/98 Removed references to continuous duty operation of
C1423M-B 8/98 Rev. B. Metal plate was added to defroster per ECO#
C1423M-C 7/01 Revised defroster kit installation instructions.
C1423M-D 10/03 Revised heater kit installation instructions, step 5b.
Incorporated Manual C1425M for defroster kits. Added instructions for installation of O/I-PCB circuit board kit. Added Operation and Care and Maintenance sections.
the heaters and defroster. Changed manual to new format.
98-3887. Added certification information.
2 Pelco Manual C1423M-D (10/03)

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis­tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C1423M-D (10/03) 3

2.0 DESCRIPTION

The information in this manual covers the installation and operation of the following kits for the EH5700/EHS700L Series environmental enclosures:
BK57-1 Blower kit, 120 VAC, 15 watts
BK57-2 Blower kit, 24 VAC, 10 watts
BK57-3 Blower kit, 230 VAC, 15 watts
HK57-1 Heater kit, 120 VAC, 100 watts
HK57-2 Heater kit, 24 VAC, 40 watts
HK57-3 Heater kit, 230 VAC, 100 watts
O/I-PCB Circuit board with thermostats
WD57-1 Window defroster kit, 120 VAC, 30 watts
WD57-2 Window defroster kit, 24 VAC, 30 watts
WD57-3 Window defroster kit, 230 VAC, 30 watts
The O/I-PCB circuit board is required for thermostatic control of the heaters and defroster. The O/I-PCB is optional with the blower kits; without the O/I-PCB, the blower will operate continuously.

2.1 CERTIFICATIONS

The products identified below have been tested and certified for agency compli­ance as noted.
Model CE FCC UL CSA/cUL
BK57-1
BK57-2 X
BK57-3 X
HK57-1
HK57-2 X
HK57-3 X
O/I-PCB X
WD57-1
WD57-2 X
WD57-3 X
Applicable CE, FCC, UL, and CSA/cUL directives/standards:
93/68/EEC – CE Mark Directive
89/336/EEC, 92/31/EEC – Electromagnetic Compatibility (EMC) Directives
EN 55022: 1984 Class B – Radio-frequency emissions limits EN 50082-2: 1992 – Immunity standard
IEC 801-2: 1984 – ESD immunity IEC 801-3: 1984 – Radiated field immunity IEC 801-4: 1988 – Electrical transients
Agency Complance Certification
4 Pelco Manual C1423M-D (10/03)

3.0 BLOWER KIT INSTALLATION

This section provides instructions for installing the BK57-1. BK57-2. and BK57-3 blower kits.
For the following instructions, refer to Figure 1. Table B lists the parts shown in Figure 1.
1. Turn off power to the enclosure.
2. Unlatch and raise the enclosure lid. The gas spring will hold the lid in place when it is fully opened.
NOTE:
If you are using your enclo­sure in a marine or high-moisture environment, skip steps 4-7. The vent covers must be left in place.
3. Remove the camera and sled.
4. Remove the vent grill inside the enclosure at the rear of the unit.
5. On the bottom of the enclosure, remove the two vent covers.
6. Place the two foam filters in the vent grill.
7. Install the vent grill in the bottom of the enclosure at the front of the unit.
8. If you are installing your enclosure in a marine or high-moisture environment, modify the fan assembly as follows:
a. Remove the four Allen screws that secure the fan to the fan plate.
b. Turn the fan around so that it will blow toward the viewing window (the
arrow on the fan points toward the fan plate).
c. Reinstall the fan on the fan plate.
9. Install the fan plate and fan in the enclosure with the hardware that is supplied:
a. Slip the fan wires into the slot at the bottom of the fan plate so that the
white plug is on the opposite side of the fan plate from the fan.
b. Place the fan plate and fan into the enclosure with the fan facing toward
the rear of the enclosure and the fan plate against the camera sled track.
c. Attach the top center of the fan plate to the enclosure with the standoff, a
screw, lock washers, and flat washers.
d. Attach the bottom right and bottom left sides of the fan plate to the cam-
era sled track with screws and lock washers.
10. Continuous Duty Operation Only - If your enclosure does not have the O/I­PCB circuit board for thermostatic control, complete the installation as follows:
a. Connect the fan to power. The BK57-1 and BK57-3 fans use 15 watts of
power. The BK57-2 uses 10 watts. If you are using 24 VAC, refer to Table A to determine the size of wire to use.
b. Reinstall the camera and sled.
c. Close the enclosure lid.
d. Turn on power.
Pelco Manual C1423M-D (10/03) 5
Table A. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)
EXAMPLE:
An enclosure that re­quires 80 vA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge of 20 Awg.
NOTE:
Distances are calculated in feet; values in parentheses are meters.
Wire Gauge
20 18 16 14 12 10
10 283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
20 141 225 358 571 905 1440
(42) (68) (109) (174) (275) (438)
30 94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
40 70 112 179 285 452 720
(21) (34) (54) (86) (137) (219)
50 56 90 143 228 362 576
(17) (27) (43) (69) (110) (175)
60 47 75 119 190 301 480
(14) (22) (36) (57) (91) (146)
70 40 64 102 163 258 411
(12) (19) (31) (49) (78) (125)
80 35 56 89 142 226 360
(10) (17) (27) (43) (68) (109)
90 31 50 79 126 201 320
(9) (15) (24) (38) (61) (97)
100 28 45 71 114 181 288
(8) (13) (21) (34) (55) (87)
110 25 41 65 103 164 261
(7) (12) (19) (31) (49) (79)
120 23 37 59 95 150 240
Total vA consumed
(7) (11) (17) (28) (45) (73)
130 21 34 55 87 139 221
(6) (10) (16) (26) (42) (67)
140 20 32 51 81 129 205
(6) (9) (15) (24) (39) (62)
150 18 30 47 76 120 192
(5) (9) (14) (23) (36) (58)
160 17 28 44 71 113 180
(5) (8) (13) (21) (34) (54)
170 16 26 42 67 106 169
(4) (7) (12) (20) (32) (51)
180 15 25 39 63 100 160
(4) (7) (11) (19) (30) (48)
190 14 23 37 60 95 151
(4) (7) (11) (18) (28) (46)
200 14 22 35 57 90 144
(4) (6) (10) (17) (27) (43)
Maximum distance from transformer to load
6 Pelco Manual C1423M-D (10/03)
Loading...
+ 14 hidden pages