Prior to installation and use of this product, the following WARNINGS should be observed.
1.Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain and moisture.
3.Only use replacement parts recommended by Pelco.
4.After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous
voltage constituting a risk of electric shock
is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
Pelco Manual C820M-D (1/01)3
DESCRIPTION
The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs
to a single monitor output using interlocked manual pushbuttons. Included in this series is
the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with
a 14 pushbutton panel.
The MS500 Series Switchers are designed for either looping or terminating operation,
depending on the model.
For the maximum
recommended cable distances refer to the installation manuals supplied with
equipment (camera, lens
and monitor) to be used with
the switcher.
TERMINATING SWITCHERS
1.Place the unit on a flat surface, or install it in an equipment rack using the appropriate
rack-mount kit.
2.Refer to Figures 1 - 6 and select the desired configuration for your installation. Make
all equipment connections as illustrated in the drawings. Refer to Table A for the type
of coaxial cable to use.
3.Plug in the power cord. The switcher will begin operating.
Table A. Video Coaxial Cable Requirements
Cable Type*Maximum Distance
RG59/U750 ft (229 m)
RG6/U1,000 ft (305 m)
RG11/U1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
When using non-looping switchers, the monitor should be terminated unless the looping
output, if available, on the monitor is used. (Refer to Figures 1 and 2.)
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
CAMERA
4321
MON
AC INPUT
MS504DT (REAR VIEW)
Figure 1. MS500 Series Switchers - Terminating Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
CAMERA
4321
MS504AF (REAR VIEW)
MON
AC INPUT
COAXITRON
TRANSMITTER
TERMINATE LOOPING
OUTPUT AT 75Ω
Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron® Transmitter
Pelco Manual C820M-D (1/01)5
LOOPING SWITCHERS
IMPORTANT:
Looping
switchers do not have internal termination. Inputs must
be terminated at 75 ohms by
other equipment in the
system.
Use coaxial cable to connect the input and looping video cables to the appropriate input
connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.)
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
CAMERA
4321
CAMERA
4321
MON
AC INPUT
MON
AC INPUT
UN-TERMINATED
MONITOR
(SWITCH IN THE
HI-Z POSITION)
MS504LDT (REAR VIEW)
MS504DT (REAR VIEW)
Figure 3. MS500 Series Switchers - Looping Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
CAMERA
4321
CAMERA
4321
MON
AC INPUT
MON
AC INPUT
MS504LDT
(REAR VIEW)
MS504DT
(REAR VIEW)
COAXITRON
TRANSMITTER
UNTERMINATED
TRANSMITTER
COAXITRON
TRANSMITTER
TERMINATE LOOPING
OUTPUT AT 75Ω
Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter
6Pelco Manual C820M-D (1/01)
SWITCHERS WITH AUDIO FOLLOW
NOTE:
Configuration does
not permit two-way communication. Microphones or
speakers, etc., can be installed at the camera site.
MS500 Series models with “AF” in the suffix have a connection for an audio signal source.
Using appropriate cable with compatible connectors, connect audio signal sources to RCA
jack (refer to Figure 5).
AUDIO IN/OUT
CAMERA
4321
MS504AF (REAR VIEW)
MON
AUDIO IN/OUT
VIDEO OUT
Figure 5. MS500 Series Switchers with Audio Follow
SWITCHERS WITH BALANCED AUDIO FOLLOW
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
NOTE:
Configuration does
not permit two-way communication. Microphones or
speakers, etc., can be installed at the camera site.
MS500 Series models with “BAF” in the suffix have terminal block connections for a twoconductor cable. This cable can be used for balanced audio follow or similar signals. (Refer
to Figure 6.)
AUDIO IN/OUT
AUDIO IN/OUT
AUDIO
AUDIO IN
1234
OUT
ABABABABAB
MS504BAF (REAR VIEW)
Figure 6. MS500 Series Switchers with Balanced Audio Follow
TERMINATE
MONITOR
(SWITCH IN THE
75Ω POSITION)
VIDEO OUT
VIDEO INMON 1
4321
Pelco Manual C820M-D (1/01)7
SWITCHERS WITH AMPLIFIED OUTPUT
The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and
a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for
proper operations.
NOTE:
MPT9000CZ/MPT9000PZ or KBD9000/KBD9000-X Coaxitron controls.
OPERATION
To operate the MS500 Series Switcher, plug in the power cord and press a camera button
to view video from the corresponding camera.
MAINTENANCE
Regularly scheduled maintenance is not required. However, maintenance may be required
in the following situations:
1.For switcher contacts that are not conducting properly, clean with a non-conducting
electrical contact spray cleaner especially made for that purpose. Remove cover for
access to the contacts and spray cleaner carefully into contacts from the rear.
2.To replace burned out bulbs in illuminated models, remove the switch cover from the
front of the unit and push the bulb upwards, then lift out. Replace with Pelco #LAP327.
Use Monitor 2 non-amplified output only when interfacing with the
IMPORTANT:
Units plugged into electrical outlets should be unplugged
before spraying contacts.
8Pelco Manual C820M-D (1/01)
AUDIO FOLLOW OPTION
BLK
1
F1
AC
INPUT
DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING
1/16 AMP
BLK/YEL
BLK/GRN
BLK/RED
-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3
Figure 7. Schematic for 4-18 Position Manual Switchers
CON 3505
RCA
JAX
T1
REMOVE JUMPER FROM 1 & 3, 2 & 4
BLK
RED
GRN
GRN/YEL
YEL
GRY
BRN
1
18 V.A.C.
1
R2
75Ω
AUDIO
INPUTS
2
I1
VIDEO
INPUTS
R2
75Ω
2
I2
TYPICAL
CONNECTION
FOR
LOOPING
N
IN
RN
75Ω
N
AUDIO
OUTPUT
VIDEO
OUTPUT
00-09
10-19
00
01
02*
47 K
27 K
220
03*
22 PF
*20-29
1 K
2N
3565
680
MON 2
VIDEO
OUTPUT
50
25 V
NOTES:
* AS REQUIRED
- FOR LOOPING, DELETE RESISTORS 75 OHM
- FOR 110 VAC INPUT JUMPER 1 & 3; 2 & 4
- FOR 220 VAC INPUT JUMPER 2 & 3
75 TYP.
*30-39
2 N
3638
100
100
TYPICAL
CONNECTION
FOR LOOPING
56 2 W
IN 4740
25
15 V
75
2000
16 V
MON I
AMPLIFIED
VIDEO OUPUT
500
50 V
IN 4005
IN 4005
YEL
GRN/YEL
GRN
RED
BLU
GRY
BRN
T 1
1
BLK
BLK/YEL
BLK/GRN
BLK/RED
2
3
4
F 1
1/16 AMP
A C
INPUT
Figure 8. Schematic for 40 Position Manual swithcers
Pelco Manual C820M-D (1/01)9
SPECIFICATIONS
VIDEO
Inputs:4, 8, 12, or 40 as indicated by the last two digits of the model
Video Connectors:BNC
Audio Connectors:
AF Switchers1/8-inch RCA phone jack
BAF SwitchersTerminal block
Output Amplifier:One amplified output and one non-amplified output for use with
Gain:Unity
Frequency
Response:Flat within ±1 dB to 10 MHz
Max. Signal
Level:2 Vp-p
MPT9000CZ/MPT9000PZ (Coaxitron® System).
10Pelco Manual C820M-D (1/01)
GENERAL
Switching:Interlocked manual pushbuttons
Construction:
CoverSteel, black polyester powder coat
ChassisSteel, zinc plated
PanelAluminum, black polyester powder coat
Environment:32° to 120°F (0° to 48.89°C)
Dimensions
MS504 Series
(except AFL,
BAF, and BAF
models):1.75 (H) x 5.3 (W) x 9.3 (L) inches
MS504AFL,
MS504BAF,
MS504BAFL, and
MS508 Series
(except AFL
model):1.75 (H) x 14.3 (W) x 9.3 (L) inches
MS508AFL,
MS512 Series,
MS518 Series, and
MS540DT (except
MS518AFL and
MS540LDT):1.75 (H) x 17.12 (W) x 9.3 (L) inches
(4.45 cm x 13.46 cm x 23.62 cm)
(4.45 cm x 36.32 cm x 23.62 cm)
(4.45 cm x 43.48 cm x 23.62 cm)
MS518AFL and
MS540LDT:3.50 (H) x 17.12 (W) x 9.3 (L) inches
(8.89 cm x 43.48 cm x 23.62 cm)
(Design and product specifications subject to change without notice.)
Pelco Manual C820M-D (1/01)11
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
• Three years on Camclosure
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy
fixed dome products.
•Two years on Spectra
continuous motion applications.
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
®
Series products (multiplexers, server, and keyboard).
®
and fixed camera models, except the CC3701H-2,
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
®
, Esprit®, ExSite™, and PS20 scanners, including when used in
®
and WW5700 Series window wiper (excluding wiper blades).
™
Series distributed network-based video products.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #DateComments
C820M3/88Original version.
C820M-A9/90Added to Warning Section for UL compliance.
C820M-B6/92Revised to cover all MS500 Series models. Added DT200 to Options section.
C820M-C10/97Revised Figures 1 and 2. Put into new format.
C820M-D1/01Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.