Pelco MS518, MS504BAFL, MS518AFL, MS540DT, MS504BAF User Manual

...
MS500 Series
Manual Switchers
Installation/
Operation Manual
C820M-D (1/01)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
CONTENTS
LIST OF ILLUSTRATIONS
Section Page
IMPORTANT SAFEGUARDS AND WARNINGS................................................................ 3
DESCRIPTION ................................................................................................................... 4
MODELS ....................................................................................................................4
INSTALLATION ..................................................................................................................5
TERMINATING SWITCHERS ....................................................................................5
LOOPING SWITCHERS ............................................................................................ 6
Coaxitron Transmitter .........................................................................................................6
SWITCHERS WITH AUDIO FOLLOW .......................................................................7
SWITCHERS WITH BALANCED AUDIO FOLLOW...................................................7
SWITCHERS WITH AMPLIFIED OUTPUT ................................................................ 8
OPERATION ......................................................................................................................8
MAINTENANCE .................................................................................................................8
SPECIFICATIONS............................................................................................................. 10
WARRANTY AND RETURN INFORMATION .................................................................... 12
Figure Page
1 MS500 Series Switchers - Terminating Configuration ........................................ 5
2 MS500 Series Switchers - Terminating Configuration with Coaxitron
Transmitter .........................................................................................................5
3 MS500 Series Switchers - Looping Configuration ............................................. 6
4 MS500 Series Switchers - Looping Configuration with ..................................... 6
5 MS500 Series Switchers with Audio Follow .......................................................7
6 MS500 Series Switchers with Balanced Audio Follow .......................................7
7 Schematic for 4-18 Position Manual Switchers .................................................. 9
8 Schematic for 40 Position Manual swithcers ..................................................... 9
LIST OF TABLES
Table Page
AVideo Coaxial Cable Requirements ................................................................... 5
®
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
Pelco Manual C820M-D (1/01) 3
DESCRIPTION
The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons. Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel.
The MS500 Series Switchers are designed for either looping or terminating operation, depending on the model.
MODELS
Terminating
MS504DT 4 inputs (UL) MS508DT 8 inputs (UL) MS512DT 12 inputs (UL) MS518DT 18 inputs (UL) MS540DT 40 inputs (UL) MS504GDT 4 inputs, illuminated buttons, 120 VAC (UL) MS508GDT Same as MS504GDT, 8 inputs (UL) MS512GDT Same as MS504GDT, 12 inputs (UL) MS512GDT/220 Same as MS512GDT except 230 VAC MS518GDT Same as MS504GDT, 18 inputs (UL)
Terminating With Audio Follow
MS504AF 4 inputs (UL) MS508AF 8 inputs (UL) MS512AF 12 inputs (UL) MS518AF 18 inputs (UL)
Terminating With Balanced Audio Follow
MS504BAF 4 inputs (UL) MS508BAF 8 inputs (UL) MS512BAF 12 inputs (UL)
Looping
MS504LDT 4 inputs (UL) MS508LDT 8 inputs (UL) MS512LDT 12 inputs (UL) MS518LDT 18 inputs (UL) MS540LDT 40 inputs, 2 monitor outputs 120 VAC (UL) MS540LDT/220 Same as MS540LDT except 230 VAC MS504GLDT 4 inputs, illuminated buttons, 120 VAC input (UL) MS504GLDT/220 Same as MS504GLDT except 230 VAC MS508GLDT Same as MS504GLDT, 8 inputs (UL) MS512GLDT Same as MS504GLDT, 12 inputs (UL) MS512GLDT/220 Same as MS512GLDT except 230 VAC MS518GLDT Same as MS504GLDT, 18 inputs (UL)
Looping With Audio Follow
MS504AFL 4 inputs (UL) MS508AFL 8 inputs (UL) MS512AFL 12 inputs (UL) MS518AFL 18 inputs (UL)
Looping With Balanced Audio Follow
MS504BAFL 4 inputs (UL) MS508BAFL 8 inputs (UL) MS512BAFL 12 input (UL)INSTALLATION
INSTALLATION
NOTE:
For the maximum recommended cable dis­tances refer to the installa­tion manuals supplied with equipment (camera, lens and monitor) to be used with the switcher.
TERMINATING SWITCHERS
1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate rack-mount kit.
2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make all equipment connections as illustrated in the drawings. Refer to Table A for the type of coaxial cable to use.
3. Plug in the power cord. The switcher will begin operating.
Table A. Video Coaxial Cable Requirements
Cable Type* Maximum Distance
RG59/U 750 ft (229 m)
RG6/U 1,000 ft (305 m)
RG11/U 1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage
When using non-looping switchers, the monitor should be terminated unless the looping output, if available, on the monitor is used. (Refer to Figures 1 and 2.)
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
4321
MON
AC INPUT
MS504DT (REAR VIEW)
Figure 1. MS500 Series Switchers - Terminating Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
4321
MS504AF (REAR VIEW)
MON
AC INPUT
COAXITRON
TRANSMITTER
TERMINATE LOOPING OUTPUT AT 75
Figure 2. MS500 Series Switchers - Terminating Configuration with Coaxitron® Transmitter
Pelco Manual C820M-D (1/01) 5
LOOPING SWITCHERS
IMPORTANT:
Looping switchers do not have inter­nal termination. Inputs must be terminated at 75 ohms by other equipment in the system.
Use coaxial cable to connect the input and looping video cables to the appropriate input connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.)
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
4321
CAMERA
4321
MON
AC INPUT
MON
AC INPUT
UN-TERMINATED
MONITOR
(SWITCH IN THE
HI-Z POSITION)
MS504LDT (REAR VIEW)
MS504DT (REAR VIEW)
Figure 3. MS500 Series Switchers - Looping Configuration
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
CAMERA
4321
CAMERA
4321
MON
AC INPUT
MON
AC INPUT
MS504LDT
(REAR VIEW)
MS504DT
(REAR VIEW)
COAXITRON
TRANSMITTER
UNTERMINATED
TRANSMITTER
COAXITRON
TRANSMITTER
TERMINATE LOOPING OUTPUT AT 75
Figure 4. MS500 Series Switchers - Looping Configuration with Coaxitron Transmitter
SWITCHERS WITH AUDIO FOLLOW
NOTE:
Configuration does not permit two-way commu­nication. Microphones or speakers, etc., can be in­stalled at the camera site.
MS500 Series models with “AF” in the suffix have a connection for an audio signal source. Using appropriate cable with compatible connectors, connect audio signal sources to RCA jack (refer to Figure 5).
AUDIO IN/OUT
CAMERA
4321
MS504AF (REAR VIEW)
MON
AUDIO IN/OUT
VIDEO OUT
Figure 5. MS500 Series Switchers with Audio Follow
SWITCHERS WITH BALANCED AUDIO FOLLOW
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
NOTE:
Configuration does not permit two-way commu­nication. Microphones or speakers, etc., can be in­stalled at the camera site.
MS500 Series models with “BAF” in the suffix have terminal block connections for a two­conductor cable. This cable can be used for balanced audio follow or similar signals. (Refer to Figure 6.)
AUDIO IN/OUT
AUDIO IN/OUT
AUDIO
AUDIO IN
1234
OUT
ABABABABAB
MS504BAF (REAR VIEW)
Figure 6. MS500 Series Switchers with Balanced Audio Follow
TERMINATE
MONITOR
(SWITCH IN THE
75 POSITION)
VIDEO OUT
VIDEO IN MON 1
4321
Pelco Manual C820M-D (1/01) 7
SWITCHERS WITH AMPLIFIED OUTPUT
The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for proper operations.
NOTE:
MPT9000CZ/MPT9000PZ or KBD9000/KBD9000-X Coaxitron controls.
OPERATION
To operate the MS500 Series Switcher, plug in the power cord and press a camera button to view video from the corresponding camera.
MAINTENANCE
Regularly scheduled maintenance is not required. However, maintenance may be required in the following situations:
1. For switcher contacts that are not conducting properly, clean with a non-conducting electrical contact spray cleaner especially made for that purpose. Remove cover for access to the contacts and spray cleaner carefully into contacts from the rear.
2. To replace burned out bulbs in illuminated models, remove the switch cover from the front of the unit and push the bulb upwards, then lift out. Replace with Pelco #LAP327.
Use Monitor 2 non-amplified output only when interfacing with the
IMPORTANT:
Units plugged into electrical outlets should be unplugged
before spraying contacts.
AUDIO FOLLOW OPTION
BLK
1
F1
AC INPUT
DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING
1/16 AMP
BLK/YEL
BLK/GRN
BLK/RED
-FOR 220 VAC INPUT ADD JUMPER TO 2 & 3
Figure 7. Schematic for 4-18 Position Manual Switchers
CON 3505
RCA
JAX
T1
REMOVE JUMPER FROM 1 & 3, 2 & 4
BLK
RED
GRN
GRN/YEL
YEL
GRY
BRN
1
18 V.A.C.
1
R2 75
AUDIO INPUTS
2
I1
VIDEO INPUTS
R2 75
2
I2
TYPICAL CONNECTION FOR LOOPING
N
IN
RN 75
N
AUDIO OUTPUT
VIDEO OUTPUT
00-09
10-19
00
01
02*
47 K
27 K
220
03*
22 PF
*20-29
1 K
2N 3565
680
MON 2 VIDEO OUTPUT
50 25 V
NOTES: * AS REQUIRED
- FOR LOOPING, DELETE RESISTORS 75 OHM
- FOR 110 VAC INPUT JUMPER 1 & 3; 2 & 4
- FOR 220 VAC INPUT JUMPER 2 & 3
75 TYP.
*30-39
2 N 3638
100
100
TYPICAL CONNECTION FOR LOOPING
56 2 W
IN 4740 25 15 V
75
2000 16 V
MON I AMPLIFIED VIDEO OUPUT
500 50 V
IN 4005
IN 4005
YEL
GRN/YEL
GRN
RED
BLU
GRY
BRN
T 1
1
BLK
BLK/YEL
BLK/GRN
BLK/RED
2
3
4
F 1
1/16 AMP
A C INPUT
Figure 8. Schematic for 40 Position Manual swithcers
Pelco Manual C820M-D (1/01) 9
SPECIFICATIONS
VIDEO
Inputs: 4, 8, 12, or 40 as indicated by the last two digits of the model
Video Connectors: BNC
Audio Connectors:
AF Switchers 1/8-inch RCA phone jack BAF Switchers Terminal block
Termination:
Terminated or Non-looping Switchers
Input 75-ohm internal termination Output 75-ohm source termination
Looping Switchers
Input High impedance looping Output High impedance looping
ELECTRICAL
(Models MS500G, MS500GL, MS540DT, and MS540LDT)
Input Voltage: 120 VAC, 50/60 Hz or 230 VAC, 50 Hz
Power Requirement: .095 amp (11 vA)
Fuse: 3 AG 1/16 amp slo-blow
number.
Power Cord: 3-wire grounded #18 AWG
(Models MS540DT and MS540LDT Only)
Output Amplifier: One amplified output and one non-amplified output for use with
Gain: Unity
Frequency Response: Flat within ±1 dB to 10 MHz
Max. Signal Level: 2 Vp-p
MPT9000CZ/MPT9000PZ (Coaxitron® System).
GENERAL
Switching: Interlocked manual pushbuttons
Construction:
Cover Steel, black polyester powder coat Chassis Steel, zinc plated Panel Aluminum, black polyester powder coat
Environment: 32° to 120°F (0° to 48.89°C)
Dimensions
MS504 Series (except AFL, BAF, and BAF models): 1.75 (H) x 5.3 (W) x 9.3 (L) inches
MS504AFL, MS504BAF, MS504BAFL, and MS508 Series (except AFL model): 1.75 (H) x 14.3 (W) x 9.3 (L) inches
MS508AFL, MS512 Series, MS518 Series, and MS540DT (except MS518AFL and MS540LDT): 1.75 (H) x 17.12 (W) x 9.3 (L) inches
(4.45 cm x 13.46 cm x 23.62 cm)
(4.45 cm x 36.32 cm x 23.62 cm)
(4.45 cm x 43.48 cm x 23.62 cm)
MS518AFL and MS540LDT: 3.50 (H) x 17.12 (W) x 9.3 (L) inches
(8.89 cm x 43.48 cm x 23.62 cm)
(Design and product specifications subject to change without notice.)
Pelco Manual C820M-D (1/01) 11
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
• Three years on Camclosure CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy fixed dome products.
•Two years on Spectra continuous motion applications.
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
®
Series products (multiplexers, server, and keyboard).
®
and fixed camera models, except the CC3701H-2,
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
®
, Esprit®, ExSite™, and PS20 scanners, including when used in
®
and WW5700 Series window wiper (excluding wiper blades).
Series distributed network-based video products.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
REVISION HISTORY
Manual # Date Comments
C820M 3/88 Original version. C820M-A 9/90 Added to Warning Section for UL compliance. C820M-B 6/92 Revised to cover all MS500 Series models. Added DT200 to Options section. C820M-C 10/97 Revised Figures 1 and 2. Put into new format. C820M-D 1/01 Added illustrations for terminated and looping configurations with a Coaxitron transmitter. Updated manual to new format.
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Coaxitron, and PelcoVision are registered trademarks of Pelco. © Copyright 2001, Pelco. ™ Esprit and Camclosure are trademarks of Pelco. All rights reserved.
Loading...