Pelco LRD41C22-2, LRD41C22-1, LRD41C21-1 Specsheet

PRODUCT SPECIFICATION
LEGACY WALL MOUNT WITH
INTEGRAL RECEIVER
LEGACY LRD41A11 RECEIVER
SHOWN WITH LRD41TLC TEST LOCAL CONTROL MODULE
communication & power
LRD41C21/LRD41C22 Series Receiver
COAXITRON®/RS-422 COMPATIBLE, FOR LEGACY® SYSTEMS
Product Features
64 Presets
Fixed Speed or Full PTZ Variable Speed Control Models Available
8 Inputs for Preset Alarms*
1 Alarm Output*
2 Relay Outputs: Aux 1 and Aux 2*
Self-Test Diagnostics
Auto/Random Scan
Camera Synchronization
Serial Com Port (RS-422)
Coaxitron® Compatible
Transient Suppression
NTSC or PAL Video
Test Local Control Capability
Adjustable Lens Voltages
For Use with Legacy® LWM41 Wall Mount
The LRD41C21/LRD41C22 Series Legacy® receiver is designed for use with our LWM41 wall mount. Standard features include 64 presets, 8 inputs for preset alarms*, and 1 alarm output. Choose from fixed speed or variable speed models for 24/120/230 VAC applications.
The LRD41C21 Series receiver is for use with fixed speed Legacy pan/tilt models PT780P, PT780P/PP, PT780SL, PT780SL/PP, PT780­24P, PT780-24P/PP, PT780-24SL, and PT780-24SL/PP. The LRD41C22 Series receiver is for use with variable speed pan/tilt models PT780­VS, PT780-VSSL, PT780-VS/PP, and PT780-VSSL/PP.
The LRD41C21/LRD42C22 Series is compatible with either Coaxitron
®
control systems utilizing standard 15-bit or extended 32­bit command protocols or Pelco serial RS-422 control systems utilizing D- or P-type protocols.
Also available is the LRD41TLC test local control module which allows on-site testing of Legacy system functions. Simply plug the TLC into the connector on the receiver and you're ready to test the system functions. The TLC module operates on +5 VDC supplied by the receiver and controls these functions: iris open/iris close, focus near/focus far, zoom telephoto/zoom wide, tilt up/tilt down, and pan left/pan right.
* Requires optional LRD41C-CONNKIT
C557 / REVISED 10-03
International Standards
Organization Registered Firm;
ISO 9001 Quality System
TECHNICAL SPECIFICATIONS
MODELS
LRD41C21-1 Legacy fixed speed receiver with up to 64
LRD41C21-2 Same as LRD41C21-1 except 24 VAC input LRD41C21-3 Same as LRD41C21-1 except 230 VAC input LRD41C22-1 Legacy variable speed receiver with up to 64
LRD41C22-2 Same as LRD41C22-1 except 24 VAC input LRD41C22-3 Same as LRD41C22-1 except 230 VAC input
presets, 120 VAC input. Use with LWM41 Legacy wall mount
presets, 120 VAC input. Use with LWM41 Legacy wall mount
MECHANICAL
RS-422 Connector 4-position connector Aux/Alarm Connector 18-position double-stack header for interface.
Video and Sync Connectors BNC Pan/Tilt Connector 37-pin connector Power Connector 6-position (mating connector on switch
Aux/Alarm mating connectors not supplied
(see OPTIONAL ACCESSORIES)
bracket)
ELECTRICAL
Input Voltage See table below
120V Models
Input Pan/Tilt Camera Enclosure
24V Models
Input Pan/Tilt Camera Enclosure
230V Models
Input Pan/Tilt Camera Enclosure
Frequency 60/50 Hz Video Input 75 ohms terminating Video Output 75 ohms terminating Video Bandwidth 10 MHz Video Gain Unity Video Formats NTSC or PAL Control Method Coaxitron, 15-bit and 32-bit protocols or
Standard Baud Rate
D-type Control 2400 baud only P-type Control 2400/4800/9600 baud
Alarm In GND to operate, +5V or open to disable Alarm Out One open collector, TTL 5 VDC, 15-25 mA Aux 1 and 2 Relay 1 A at 24 VDC Lens Output Voltage 6 VDC to 10 VDC Current 25 mA at 10 VDC, 100 mA at 9 VDC
LRD41C21-1
120 VAC 120 VAC 24 VAC 120 VAC
LRD41C21-2
24 VAC 24 VAC 24 VAC 24 VAC
LRD41C21-3
230 VAC 120 VAC 24 VAC 230 VAC
2-wire RS-422
LRD41C22-1
120 VAC 12 VDC 24 VAC 120 VAC
LRD41C22-2
24 VAC 12 VDC 24 VAC 24 VAC
LRD41C22-3
230 VAC 12 VDC 24 VAC 230 VAC
Operating Distances Cable distances are approximate according to
Coaxitron Version 750 ft (229 m) on RG59/U RS-422 Version 4,000 ft (1,219 m) on 24 AWG twisted pair (for
Fuse Values F1 F2
LRD41C21-1 2A ZA LRD41C21-2 2.5A 6.3A LRD41C21-3 500 mA 1A
LRD41C22-1 400 mA 2A LRD41C22-2 1.25A 6.3A LRD41C22-3 160 mA 1A
Model Receiver* Enclosure/Accessories**
LRD41C21-1 LRD41C21-2 LRD41C21-3 LRD41C22-1 LRD41C22-2 LRD41C22-3
* Current required to run the receiver, pan/tilt, camera, and lens. **Current required for maximum enclosure options (heaters, wiper, blower,
defroster, and pan/tilt heater blankets).
cable type used. 75-ohm coax required
point-to-point and daisy-chain configurations only)
Input Power (LRD) Enclosure
LRD Input Current Table
500 mA
2 A 250 mA 200 mA
1 A 100 mA
1.5 A 6 A
900 mA
1.5 A 6 A
900 mA
GENERAL
Operating Temperature 0° to 110°F (-18° to 43°C) Case Dimensions 11.5" L x 4.5" W x 2.75" H
Finish Alodine Unit Weight 5 lb (2.27 kg) Shipping Weight 6 lb (2.72 kg)
(29.21 x 11.43 x 6.98 cm)
CERTIFICATIONS
• CE, Class A (all models)
• FCC, Class A (all except 230 VAC models)
OPTIONAL ACCESSORIES
LRD41TLC Test local control module. Receiver plug-in
LRD41C-CONNKIT Two 9-pin connectors that interface with the
LWM41 Legacy wall mount.
module for on-site testing of Legacy system functions
18-position double-stack Aux/Alarm connector on the receiver. Required to enable the Aux/Alarm capabilities of the receiver.
Pelco Worldwide Headquarters:
3500 Pelco Way, Clovis, California 93612-5699 USA
USA & Canada Tel: (800) 289-9100 • FAX (800) 289-9150 International Tel: (559) 292-1981 • FAX (559) 348-1120 www.pelco.com
Pelco, the Pelco logo, Legacy, and Coaxitron are registered trademarks of Pelco.
Specifications subject to change without notice.
©Copyright 2003, Pelco. All rights reserved.
Loading...