Pelco IE-P Specsheet

INSTALLATION

IE-P Pendant Mount Adapter

C2239M (11/09)

Contents

Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
C2239M (11/09) 3

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Only use attachments/accessories specified by the manufacturer.
6. Installation should be done only by qualified personnel and conform to all local codes.
7. Use only installation methods and materials capable of supporting four times the maximum specified load.
8. Only use replacement parts recommended by Pelco.
4 C2239M (11/09)

Description

The IE-P is a pendant mount adapter specifically designed for IE and IEE Series network dome cameras. The pendant adapter modifies the network dome camera for pendant installations using a
1.5-inch (3.81 cm) NPT mount, such as the SWM-GY or IWM-GY mount.

PARTS LIST

Remove all of the contents from the shipping box.
Qty
Description
1
IE-P pendant mount adapter
1
Tube of Loctite
3
10-32 Phillips pan head screws
1
Installation manual
Installation tools and the following parts are needed but not supplied:
Qty
Description
1
IE or IEE Series network dome camera
1
1.5-inch (3.81 cm) NPT mount, such as the SWM-GY or IWM-GY mount
1
Lens (use either a megapixel or standard auto iris lens, depending on camera model)
1
IX-SC service cable
1
Mounting hardware
®
C2239M (11/09) 5

Installation

Pin DC (AID) Auto Iris Lens
1 Control coil negative (–)
2 Control coil positive (+)
3 Drive coil positive (+)
4 Drive coil negative (–)
1. Install the 1.5-inch (3.81 cm) NPT mount; refer to the instructions supplied with the mount.
2. Pull the system power and video wiring through the mount.
3. Route the wiring through the IE-P pendant mount adapter. Apply Loctite (supplied) to the threads of the IE-P, and then screw the pendant mount adapter onto the mount.
Figure 1. Installing the Pendant Mount Adapter
4. Install the lens on the IE or IEE Series back box:
NOTE: Megapixel lenses are designed and tested to deliver optimal image quality to megapixel cameras. A standard definition lens installed on a megapixel camera will limit the resolution of the camera and create poor image quality.
a. Remove the cover from the lens mount.
b. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space
between the lens and the imager. If necessary, use clean, compressed air to remove any foreign matter (refer to the instructions shipped with the lens).
c. Connect the auto iris lens to the 4-pin connector located on the side of the camera. Refer to
Figure 2 for pin designation and iris drive connector information.
3
12
6 C2239M (11/09)
4
Figure 2. Lens Pin Connections
5. Connect the network cable to the RJ-45 network port. If the network has no Power over Ethernet
1
2
3
4
5
6
7
8
8 7 6 5
4 3
2
1
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
8 7 6 5 4 3 2 1
8
8
1
1
Pin Function
1TX+
2TX
3RX+
4PoE 1-2
5PoE 1-2
6RX
7PoE 3-4
8PoE 3-4
(PoE), connect a 24 VAC Class 2 power supply to the 24 VAC power connector.
Figure 3. RJ-45 Pin Descriptions
6. Connect the wiring for the alarms and relays.
Table A. Alarm and Relay Wire Descriptions
Wire Color Description
Brown Line In + White/Brown Line In – Orange Line Out + White/Orange Line Out – Green/White Relay Return Green Relay Out Blue Alarm In Blue/White Alarm Return
7. Connect the 24 VAC power wires to operate the heater inside the dome. If PoE is not available, 24 VAC also supplies power to the camera. Refer to Table B for wire descriptions and Table C for wiring distances.
Table B. 24 VAC Wire Descriptions
Wire Color Description
Red 24 VAC + Black 24 VAC –
Table C. 24 VAC Wiring Distances
AC/DC Total
VA/ Total
Watts
20 AWG 18 AWG 16 AWG 14 AWG
23 VA/15 W 123 ft (38 m) 196 ft (60 m) 311 ft (95 m) 495 ft (151 m)
75 VA/65 W 39 ft (12 m) 62 ft (19 m) 98 ft (30 m) 156 ft (48 m)
Wire Gauge
C2239M (11/09) 7
NOTES:
Power consumption for the IE and IEE Series cameras is 60 VA with the heater running.
Use a 24 VAC transformer with a minimum of 100 VA per dome.
If you are operating the camera using 24 VAC and you are wiring more than one camera to the same transformer, connect one side of the transformer to the red wire (24 VAC +) and connect the other side of the transformer to the black wire (24 VAC –). Failure to connect all modules identically might introduce video noise for some installations.
8. Install the back box: a. Install the back box in the pendant mount adapter. Line up the back box screws with the three
mounting screw holes on the pendant mount adapter.
b. Install the three 10-32 Phillips pan head screws (supplied) through the threaded holes in the
back box.
c. Tighten the machine screws completely to secure the back box to the pendant mount adapter.
Figure 4. Installing the Back Box
9. Apply power to the camera. The camera will complete a configuration sequence: the green LED flashes five times per second for approximately two minutes and then turns solid after the sequence is complete.
NOTE: If the camera is not connected to a Dynamic Host Configuration Protocol (DHCP) server and DHCP is enabled, the configuration sequence might take up to five minutes to complete.
10. To complete the installation, refer to the IE Series Installation/Operation manual or the IEE Series Installation/Operation manual.
8 C2239M (11/09)

Specifications

MECHANICAL
Mounting Method Attach the IE-P to a mount with 1.5-inch (3.81 cm) NPT pipe (such
GENERAL
Construction Aluminum
Finish Polyester powder coat
Unit Weight 1.69 lb (0.77 kg)
(Design and product specifications subject to change without notice.)
as the SWM-GY or IWM-GY mount)
0.49
(1.20)
4.95
(12.60)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE IN INCHES.
7.63
(19.40)
C2239M (11/09) 9
REVISION HISTORY
Manual # Date Comments
C2239M 11/09 Original version.
Pelco, the Pelco logo, Camclosure, Digital Sentry, Endura, Esprit, ExSite, Gene x, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc. Spectra III is a trademark of Pelco, Inc. DLP is a registered trademark of Texas Instruments Incorporated. All product names and services identified throughout this document are trademarks or registered trademarks of their respective companies. The absence of a trademark or registe red trademark from this document does not constitute a waiver of intellectual p roperty rights. © Copyright 2009, Pelco, Inc. All rights reserved.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
10 C2239M (11/09)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, an y merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years: – Fiber optic products – Unshielded Twisted Pair (UTP) transmission products – CC370 1H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models
• Three years: – Pe lco-designed fixed network cameras and network dome cameras with Sarix™ technology. – Pe lco-branded fixed camera models (CCC1390H Series, C10DN Series, C10CH Series, and IP3701H Series) – EH150 0 Series enclosures
®
– Spectra
IV products (including Spectra IV IP)
– Cam closure – DX Se ries digital video recorders, DVR5100 Series digital video recorders, Digital Sentry
– En dura – Ge nex® Series products (multiplexers, server, and keyboard) – PMCL200/300/400 Series LCD monitors
• Two years: – S tandard varifocal, fixed focal, and motorized zoom lenses. – DF5/DF8 Series fixed dom e products – Lega cy® Series integrated positioning systems – Spectra III™, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20 scanners, including when u sed in continuous motion applications. – Espr it Ti and TI2500 Series thermal imaging products – Espr it and WW5700 Series window wiper (excluding wiper blades). – CM 6700/CM6800/CM9700 Series matrix – Di gital Light Processing (DLP®) displays (except lamp and color wheel). The lamp and color wheel will be covered for a period of 90 days.
– Inte lli-M – PMC L542F, PMCL547F, and PMCL552F FHD monitors
•One year: – Video cassette record ers (VCRs), except video heads. Video heads will be covered for a period of six months.
• Six months: – Al l pan and tilts, scanners, or preset lenses used in continuous motion applicatio ns (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated locatio n. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are no t covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of prof it, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with spe cific legal rights. The Dealer may also have additional right s, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800 ) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall un der the warranty conditions stated above, please include a written explanation with the product wh en returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid
®
Series (IS, ICS, IP) integrated camera systems
recorders, and NVR300 Series network video r ecorders
®
Series distributed network-based video pro ducts
The air filter is not covered under warranty.
®
eIDC controllers
®
Series hardware products, DVX Series digital vide o
10-19-09
www.pelco.com
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
Loading...