Pelco FUMS-FFX8, FUMS-FFX4TX4, FUMS-FFX4, FUMS-FFX2TX2, FUMS-FTX8 User Manual

...
INSTALLATION AND OPERATION MANUAL
FUMS-F(FX,TX)(2,4,8)[TX(2,4)] Series
4- OR 8-PORT UNMANAGED ETHERNET SWITCHES
This manual serves the following Model Numbers:
FUMS-FFX8
FUMS-FFX4TX4
FUMS-FTX8
FUMS-FFX4
FUMS-FFX2TX2
FUMS-FTX4
The Pelco Series of four and eight port unmanaged Ethernet switches are designed
to transmit and receive 10/100Mbps data over optical fiber through user selectable
FSFP options or 10/100Mbps data over CAT5E/6 electrical cable. These units
The FUMS-FFX4TX4, FUMS-FFX2TX2, FUMS-FTX8 and FUMS-FTX4 require
the ordering of sold-separately interchangeable Pelco FSFP modules for fiber
type, distance and connectors.
All electrical interfaces will Auto-Negotiate to 10Mbps, or 100Mbps Ethernet
rate without any adjustments. The optical interfaces operate at a 100Mbps
Ethernet rate.
The models in this series are environmentally hardened to operate in
demanding environments.
LED indicators are provided for confirming equipment operating status.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 10 for installation instructions.
See Figures 1 – 14 for complete installation details.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C3927M-A / REV 07-28-14
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. Switch does not support Internet Group Management Protocol (IGMP) and should not be used as a core switch.
20. A CCC-approved power cord must be used to power this equipment when used in China.
21. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 1 – FUMS-FFX4TX4
AND RJ-45
SELECTION OF FSFP MODULES
OPTICAL FIBERS DETERMINED BY
FIGURE 2 – FUMS-FFX4TX4
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 3 – FUMS-FFX8
SELECTION OF FSFP MODULES
OPTICAL FIBERS DETERMINED BY
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
FIGURE 4 – FUMS-FFX8
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 5 – FUMS-FTX8
RJ-45
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
FIGURE 6 – FUMS-FTX8
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 7 – FUMS-FFX2TX2
SELECTION OF
OPTICAL FIBERS
FSFP MODULES
DETERMINED BY
RJ-45
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
FIGURE 8 – FUMS-FFX2TX2
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 9 – FUMS-FFX4
SELECTION OF FSFP MODULES
OPTICAL FIBERS DETERMINED BY
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
FIGURE 10 – FUMS-FFX4
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 11 – FUMS-FTX4
RJ-45
BLACK WITH WHITE STRIPES BLACK Power Supply: Surface Mount: 8-15 VDC @ 2W Rack Mount: From Rack
FIGURE 12 – FUMS-FTX4
NOTE: Remove Electrical
Connector for Rack Mount Units
RE AR PA NELFRONT PANEL
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3927M-A / REV 07-28-14
INSTALLATION AND OPERATION MANUAL FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
FIGURE 13 – POSSIBLE ETHERNET CONFIGURATION
Ethernet IEEE 802.3 Network Element determined by user.
Optical Fiber
SC or LC
Connectors
SINGLE FIBER
FSFP MODULE
CAT5e/6 with
RJ45 Connections
Ethernet IEEE
802.3 Network Element
FIGURE 14 – LED INDICATORS
ACTIVITY (SFP) RJ45 POWER GREEN YELLOW
OFF
Link/Activity Link/Activity Unit powered up
Highest Data Rate
Unit Powered Down No Link/Activity Unit Powered Down
FUMS-FFX4TX4A FUMS-FFX4TX4B
Negotiated
CAT5e/6 with
RJ45 Connections
Ethernet IEEE
802.3 Network Element
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C3927M-A / REV 07-28-14
MECHANICAL INSTALLATION INSTRUCTIONS FUMS-F(FX,TX)(2,4,8)[TX(2,4)] SERIES
13
11.9cm [4.7in]
15cm
[5.9in]
7. 5cm [2.9in]
0.63cm [0.25in]
INSTALLATION CONSIDERATIONS
The FUMS-F models are supplied as Standalone/Rack modules. Units should be installed in dry locations protected from extremes of temperature and humidity.
CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, the manufacturer recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
FIGURE A
Dimensions are for standard one and two slot modules
.2cm
[5.2in]
11.9cm [4.7in]
7. 5cm
0.63cm [0.25in]
2.75cm [1.1in]
5.5cm [2.2in]
[2.9in]
15cm
[5.9in]
B) Reduced Air Flow - Installation of the equipment in a rack should be
such that the amount of air flow required for safe operation of the equipment is not compromised.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C3927M-A / REV 07-28-14
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years: – Fiber optic products – Unshielded Twisted Pair (UTP) transmission products – CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
• Three years: – FD Series and BU Series analog camera models – Fixed network cameras and network dome cameras with Sarix – Sarix thermal imaging products (TI and ESTI Series) – Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,
and C10CH Series) – EH1500 Series enclosures – Spectra – Spectra HD dome products – Camclosure
®
IV products (including Spectra IV IP)
®
IS Series integrated camera systems
– DX Series video recorders (except DX9000 Series which is covered for a
period of one year), DVR5100 Series digital video recorders, Digital Sentry
Series hardware products, DVX Series digital video recorders, and NVR300
Series network video recorders
®
– Endura – Genex
Series distributed network-based video products
®
Series products (multiplexers, server, and keyboard) – PMCL200/300/400 Series LCD monitors – PMCL5xxF Series and PMCL5xxNB Series LCD monitors – PMCL5xxxBL Series LED monitors
• Two years: – Standard varifocal, fixed focal, and motorized zoom lenses – DF5/DF8 Series fixed dome products
®
– Legacy – Spectra III
Series integrated positioning systems
, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, ExSite IP, and
PS20 scanners, including when used in continuous motion applications – Esprit Ti and TI2500 Series thermal imaging products – Esprit and WW5700 Series window wiper (excluding wiper blades) – CM6700/CM6800/CM9700 Series matrix – Digital Light Processing (DLP
®
) displays (except lamp and color wheel). The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.
®
technology
• Six months: – All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes)
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the
®
following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
Revised 10-9-12
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Pelco, the Pelco logo, and other trademarks associa ted with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. © Copyright 2013, Pelco, Inc. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.
Pelco by Schneider Electric 3500 Pelco Way Clovis, California 93612-5699 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com www.pelco.com/community
Loading...