INSTALLATION AND OPERATION MANUAL
FTV/FRV80D2(M,S)1(ST,FC)
8-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO
+ 2 BIDIRECTIONAL DATA CHANNELS
+ 1 BIDIRECTIONAL CONTACT CLOSURE
The FTV/FRV80D2(M,S)1(ST,FC) series transmits eight channels of video
utilizing state of the art 10-bit digital encoding and decoding for very high quality
video transmission, along with two channels of bidirectional data and one
bidirectional contact closure over one single mode or multimode optical fiber.
This equipment is environmentally hardened and suitable for use in
unconditioned roadside or out-of plant installations.
The FTV/FRV80D2(M,S)1(ST,FC) is compatible with NTSC, PAL and SECAM
video transmission protocols and supports bi-directional RS232, RS422 and
RS485 (2W/4W) data. See Figure 4 on Page 4 for data selection.
See Figure 6 on Page 6 for contact switch positions.
Bi-Color LED indicators are provided to indicate the status of the system, video
and data. See Figure 7 on Page 6 for LED indication explanations.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 7 for mounting instructions.
See Figures 1 – 7 for complete installation details. No additional parts or power
supplies are required.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C5635M / REV 03-30-12
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit
from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use
caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the
apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must
not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not
perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981 C5635M / REV 03-30-12
INSTALLATION AND OPERATION MANUAL FTV/FRV80D2(M,S)1(ST,FC)
GND
+Vin
PWR
1234
OPTICAL
IN/OUT
VIDEOOUT
5678
DATA 1
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
DATA 2
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
OUT
OUT
IN
IN
CONTACT
GND
+Vin
PWR
1234
OPTICAL
IN/OUT
VIDEOIN
5
6
7
8
DATA 1
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
DATA 2
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
OUT
OUT
IN
IN
CONTACT
GND
+Vin
PWR
1234
OPTICAL
IN/OUT
VIDEOOUT
5678
DATA 1
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
DATA 2
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
OUT
OUT
IN
IN
CONTACT
FIGURE 1 – FTV/FRV80D2(M,S)1(ST,FC) TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE
OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
Power Supply:
Surface Mount: 8-15 VDC @ 4W
Rack Mount: From Rack
FIGURE 2 – TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FTV80D2S1ST
8CHANNEL DIGITALVIDEO
TRANSMITTER
+
2CHANNELSOF
BI-DIRECTIONAL DATA
BI-DIRECTIONAL CONTACT
LINK
VIDEO1
VIDEO 2
VIDEO 3
VIDEO 4
POWER
+
VIDEO 5
VIDEO 6
VIDEO7
VIDEO 8
1234
12 12
ON
DATA 1
DATA 2
GND
BIAS
DOUT DOUT +
CONTACT
TERM
DIN DIN +
GND
BIAS
DATA 1
DOUT DOUT +
TERM
DATA 2
DIN DIN +
OUT
OUT
NOTE: Remove Electrical
Connector for Rack Mount Units
FIGURE 3 – RECEIVER
FRV80D2S1ST
8CHANNELDIGIT AL VIDEO
RECEIVER
+
IN/OUT
OPTICAL
DATA 1
DATA 2
VIDEOIN
IN
IN
CONTACT
5
6
7
8
GND
+Vin
1234
PWR
2CHANNELSOF
BI-DIRECTIONAL DATA
+
VIDEO 5
VIDEO6
VIDEO 7
VIDEO8
BI-DIRECTIONAL CONTACT
LINK
VIDEO 1
VIDEO 2
VIDEO 3
VIDEO 4
POWER
1234
12 12
ON
DATA 1
DATA 2
GND
BIAS
DOUT DOUT +
CONTACT
TERM
DIN DIN +
DATA 1
DOUT DOUT +
TERM
DATA 2
DIN DIN +
GND
BIAS
OUT
OUT
IN
IN
DATA 1
DATA 2
VIDEOOUT
CONTACT
5678
GND
+Vin
IN/OUT
OPTICAL
1234
PWR
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
C5635M / REV 03-30-12