Pelco C6825 User Manual

INSTALLATION/OPERATION
C6806 and C6825
®
Prewired Cables
C936M-A (6/04)
DESCRIPTION
The C6806 and C6825 are prewired cables used to connect Pelco’s CX9024RX Coaxitron® receiver with Pelco’s PT680-24P pan/tilt. These cables operate the pan/tilt in a noninverted mode.
MODELS
C6806 Six-foot (1.82 m) cable for use with PT680-24P, PT680-24SL pan/tilts and non-preset receivers (not for inverted operation) C6825 Same as C6806 except 25-foot (7.62 m) cable length
INSTALLATION
1. Run the cable from the receiver to the pan/tilt. Be careful not to abrade or cut the jacket on the cable.
2. Connect the 37-pin CPC connector to the CX9024RX receiver.
3. Connect the 16-socket CPC connector to the PT680-24P pan/tilt.
4. Use a controller to test the following functions:
Pan Left Pan Right Tilt Up Tilt Down Zoom Wide Zoom Tele Iris Open Iris Closed Focus Near Focus Far
If all the above functions operate correctly, the installation process is complete. If all the above functions do not operate correctly, refer to
Troubleshooting
.
SPECIFICATIONS
MECHANICAL
Connectors
Receiver Side: CPC, 37 pins Pan/Tilt Side: CPC, 16 sockets
ELECTRICAL
Cable: 12 conductors with shield, 20 AWG
GENERAL
Dimensions
C6806: 6 ft (1.82 m) long C6825: 25 ft (7.62 m) long
6 conductors with shield, 20 AWG RG59/U
Maximum Wire Temperature: 140°F (60°C)