Pelco C1487M-H User Manual

Page 1
®
SD5 Series
Spectra II™ and
Spectra Lite™
Dome Systems
Installation Manual
C1487M-H (1/01)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
Page 2
2 Pelco Installation Manual C1487M-H (1/01)
Page 3
CONTENTS
Section Page
IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................... 4
INSTALLATION .......................................................................................................................................................................5
HARD CEILING INSTALLATION .................................................................................................................................... 6
SUSPENDED CEILING INSTALLATION ....................................................................................................................... 8
PENDANT-MOUNT INSTALLATION ............................................................................................................................. 10
SURFACE-MOUNT INSTALLATION ............................................................................................................................. 12
TROUBLESHOOTING ...........................................................................................................................................................14
APPENDIX .............................................................................................................................................................................15
SPECIFICATIONS .................................................................................................................................................................19
CERTIFICATIONS AND REGULATORY NOTICES .......................................................................................................23
WARRANTY AND RETURN INFORMATION ........................................................................................................................24
LIST OF ILLUSTRATIONS
Figure Page
1 SD5 Series Dimension Drawing ............................................................................................................................20
LIST OF TABLES
Table Page
AVideo Coaxial Cable Wiring Distances .................................................................................................................. 15
B 24 VAC Wiring Distances .......................................................................................................................................15
C Switch Settings for SW1 ........................................................................................................................................ 15
D Switch Settings for SW2 – P-Type Control ............................................................................................................ 16
E Switch Settings for SW2 – D-Type Control ............................................................................................................ 16
Pelco Installation Manual C1487M-H (1/01) 3
Page 4
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
MEASURES DE SECURITE IMPORTANTES
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et conformes au codes locaux.
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4, 4X, 6 ou 6P, il est uniquement conçu pour utilisation intérieure et ne peut donc pas être en contact de pluie ou d’humidité.
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.
4. Après toute installation ou réparation de la partie électrique de ce produit, une résistance entre le courant et la partie exposée devrait être installée afin de vérifier que la partie électrique n’aie pas été en contact d’un court circuit.
5. L’installation entreprise et le matériel utilisé devraient supporter quatre fois le poids du boitié, de la tourelle, de la caméra, et de la lentille.
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:
Ce symbol indique qu’un voltage dangereux pouvant provoquer un chock électrique est présant dans cette unité.
RISQUE DE CHOQUE ÉLECTRIQUE.
Ce symbol indique qu’il y a des mesures d’installation et d’entretient importantes inclus dans le manuel de cet équipement.
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute installation.
CAUTION:
NE PAS OUVRIR.
4 Pelco Installation Manual C1487M-H (1/01)
Page 5
INSTALLATION
The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes. Inspect each box to make sure all parts are present.
IN-CEILING MODELS
Back Box
1 Back box 1 Parts bag
1 Conduit fitting 1 Safety chain bracket 1 Lock nut 1 Compass tool 4T-rail clip (clip, L-bracket, screw, lock washer and nut)
Dome Drive
1 Dome drive
Lower Dome
1 Acrylic lower dome with trim ring
BACK BOX
PENDANT MODELS
Back Box
1 Back box 1Tube of thread compound
Dome Drive
1 Dome drive
Lower Dome
1 Acrylic lower dome with trim ring 1 Parts bag (O-ring and lubricant, and tube of Loctite)
BACK BOX
DOME DRIVE
DOME DRIVE
LOWER DOME
COMPASS TOOL
SAFETY BRACKET
T-RAIL CLIP
CONDUIT FITTING & LOCK NUT
LOWER DOME
THREAD
COMPOUND
LOCTITE®
222MS
O-RING
LUBE
O-RING
Pelco Installation Manual C1487M-H (1/01) 5
Page 6
HARD CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING
a. Locate the center point of the mounting location. Drill a hole in
the ceiling using a 3/32-inch drill. Insert the compass tool into the hole.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg).
b. Draw a circle on the ceiling using the compass tool and a
pencil. Cut the circle out of the ceiling.
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting. Refer to Tables A and B in the Appendix for wiring distances.
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until you hear a clicking noise.
6 Pelco Installation Manual C1487M-H (1/01)
Page 7
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
d. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power. The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
Trouble-
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
LABEL
SW2
COAXITRON CONTROLLER
2 WIRE CONTROLLER
SPECTRA II ONLY
+5 to +24 VDC
LOGIC GATE
(WIRING EXAMPLE)
EXTERNAL RELAY
(WIRING EXAMPLE)
CONTROLLER
VIDEO IN
+5 VDC
GREEN
TAB
TX­TX+
NOT USED NOT USED
SWITCHES
(WIRING EXAMPLE)
AUX 2
RED
TAB
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TX­TX+
1 2
ALARM
3
INPUTS
4 5 6 7 GROUND
(NO) (NC)
GROUND
HEATER/FAN
(NOT USED)
RELAY
(AUX 1)
AUX 2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the labels on the dome drive or Tables C through E in the Appen­dix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the last unit in the chain (farthest from the controller). To terminate the dome drive set the RS-422 termination switch to the left.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the side with red tab. Continue pushing on the ends of the tabs until both sides click into place.
Pelco Installation Manual C1487M-H (1/01) 7
Page 8
SUSPENDED CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING TILE
NOTE: The ceiling tile cannot be thinner than 0.50-inch (1.27 cm) or thicker than 1.75-inches (4.45 cm).
a. Remove the ceiling tile from the ceiling. Insert the compass tool (supplied) into the center of the tile. (If necessary use a 3/32-inch bit
to drill a hole.)
b. Draw a circle on the tile using the compass tool and a pencil. Cut the circle out of the ceiling tile.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg).
CEILING TILE
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting. Refer to Tables A and B in the Appendix for wiring distances.
T-RAIL CLIP FOR
T-RAIL CLIP FOR CEILING TILE
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until you hear a clicking noise.
d. Install the ceiling tile with the back box. Attach a T-rail clip on
each side of the ceiling tile. Fasten the L-bracket to the clip with the supplied screw and washers.
8 Pelco Installation Manual C1487M-H (1/01)
Page 9
e. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power. The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
Trouble-
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
COAXITRON CONTROLLER
2 WIRE CONTROLLER
+5 to +24 VDC
(WIRING EXAMPLE)
CONTROLLER
SPECTRA II ONLY
LOGIC GATE
24 VAC
TRANFORMER
VIDEO IN
TX­TX+
(WIRING EXAMPLE)
+5 VDC
NOT USED NOT USED
SWITCHES
POWER
(24 VAC ONLY)
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TX­TX+
1 2
ALARM
3
INPUTS
4 5 6 7 GROUND
(NO) (NC)
GROUND
RELAY
(AUX 1)
AUX 2
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the labels on the dome drive or Tables C through E in the Appen­dix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the last unit in the chain (farthest from the controller). To terminate the dome drive set the RS-422 termination switch to the left.
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
RED
TAB
HEATER/FAN
(NOT USED)
EXTERNAL RELAY
(WIRING EXAMPLE)
GREEN
TAB
AUX 2
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the side with red tab. Continue pushing on the ends of the tabs until both sides click into place.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01) 9
Page 10
PENDANT-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - MOUNT AND INSTALL THE BACK BOX
NOTE: If installing outdoors make sure the installation is properly sealed to keep moisture out.
a. Install the mount for the pendant dome. Refer to the instruc-
tions supplied with the mount. Bring the wiring for the dome
b. Turn the thumbscrew and open the hinged door located inside
the back box. through the mount. Refer to Tables A and B in the Appendix for wiring distances.
c. Pull wiring from the mount into the back box. d. Screw the back box into the mount. If outdoors, apply thread
compound (provided) to the threads on the back box.
STEP 2 - WIRE CIRCUIT BOARD
Attach the wiring to the interconnect circuit board inside the back box. Close the door to the back box. Turn on power to the back box. The red LED will light.
IMPORTANT: If the LED does not light, refer to the Trouble­shooting section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
COAXITRON CONTROLLER
2 WIRE CONTROLLER
+5 to +24 VDC
(WIRING EXAMPLE)
CONTROLLER
SPECTRA II ONLY
LOGIC GATE
24 VAC
TRANFORMER
VIDEO IN
TX­TX+
(WIRING EXAMPLE)
+5 VDC
NOT USED NOT USED
SWITCHES
POWER
(24 VAC ONLY)
VIDEO OUT
RX-
CONTROL
RX+ TX­TX+
1 2
ALARM
3
INPUTS
4 5 6 7
GROUND
(NO) (NC)
GROUND
(RS-422)
RELAY
(AUX 1)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
10 Pelco Installation Manual C1487M-H (1/01)
Page 11
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the labels on the dome drive or tables C through E in the Appendix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 4 - INSTALL LOWER DOME
RED
GREEN
TAB
TAB
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
NOTE: If you are install­ing an outdoor model, plug the two-pin heater connection in the lower dome into the mating connector in the back box.
LEASH
ATTACH LEASH TO NEAREST RETAINER SCREW
MOUNTING SCREW HOLES FRONT & BACK
b. Attach the back box trim leash to the lower dome. Use retainer
screw (nearest to a mounting screw) inside lower dome.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite 222MS (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01) 11
Page 12
SURFACE-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - REMOVE THE TOP PORTION OF THE BACK BOX
a. Turn the thumbscrew and open the
hinged door located inside the back box.
b. Unscrew the three Phillips screws lo-
cated underneath the hinged door.
c. Remove the top portion of the back box.
STEP 2 - PREPARE SURFACE AND INSTALL THE BACK BOX
NOTE: If installing outdoors apply a sealant between the back box and the mounting surface
a. Determine the mounting location. Use the base of the back box as a template. Mark the fastener and center hole positions onto the
mounting surface.
b. Drill a hole in the center of the mounting surface. Pull wiring through the opening. Refer to Tables A and B in the Appendix for wiring
distances. Prepare the holes for the fasteners. Position the back box over the mounting holes and pull wiring into the back box. Secure the back box to the mounting surface using the appropriate hardware for your installation.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
STEP 3 - WIRE CIRCUIT BOARD
Attach the wiring to the interconnect circuit board inside the back box. Close the door to the back box. Turn on power to the back box. The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
Trouble-
COAXITRON CONTROLLER
2 WIRE CONTROLLER
SPECTRA II ONLY
+5 to +24 VDC
LOGIC GATE
(WIRING EXAMPLE)
EXTERNAL RELAY
(WIRING EXAMPLE)
CONTROLLER
VIDEO IN
TX­TX+
+5 VDC
NOT USED NOT USED
SWITCHES
(WIRING EXAMPLE)
AUX 2
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TX­TX+
1 2
ALARM
3
INPUTS
4 5 6 7 GROUND
(NO) (NC)
GROUND
HEATER/FAN
(NOT USED)
RELAY
(AUX 1)
AUX 2
12 Pelco Installation Manual C1487M-H (1/01)
Page 13
STEP 4 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the labels on the dome drive or Tables C through E in the Appen­dix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 5 - INSTALL LOWER DOME
RED
GREEN
TAB
TAB
last unit in the chain (farthest from the controller). To terminate the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the side with red tab. Continue pushing on the ends of the tabs until both sides click into place.
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
NOTE: If you are install­ing an outdoor model, plug the two-pin heater connection in the lower dome into the mating connector in the back box.
LEASH
ATTACH LEASH TO NEAREST RETAINER SCREW
MOUNTING SCREW HOLES FRONT & BACK
b. Attach the back box trim leash to the lower dome. Use the
retainer screw (nearest to a mounting screw) inside lower dome.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01) 13
Page 14
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Unit does not operate. The controller is not communicating with the Spectra unit.
Check to see if the red LED on the circuit board in the back box is lit.
1. The red LED is not lit. a. Fuse is bad.
b. 24 VAC power source is not con-
nected or back box is bad.
2. The red LED is lit. a. Wiring is incorrect or is not fully
seated.
b. DIP switch settings are incorrect.
a. Check fuse on the circuit board. Replace fuse if
it is bad. To order a fuse from Pelco, specify the part number FUS1.6-5X20FAST. This is a 1.6­ampere fuse, 5 x 20 mm, fast blow.
b. Use a voltmeter to check if 24 VAC is getting to
the power connector on the circuit board. If NO, check your power supply. If YES, return the back box to the factory for repair.
a. Check all connections to the circuit board.
Make sure that all connections are fully seated and the board is wired correctly.
b. Check the DIP switch settings on the dome
drive (refer to Tables C, D, and E). If the unit still does not operate, turn off power and replace the dome drive with a good unit, if you have a spare. Check the switch settings on the substi­tute dome drive before installing it. (If you do not have a spare, return the dome drive and back box to the factory.) If you substituted a dome drive and the unit operates, the original dome drive is bad (return the dome drive to the factory). If the unit still does not operate, then the circuit board is bad (return the back box to the factory).
Fan does not operate.
Fan connections are not fully seated.
Make sure the connector for the fan is fully seated. If the fan still does not operate, return the back box and dome drive to the factory for repair.
Vertical roll on monitor when switching between cameras.
Cameras are out of phase.
If you are wiring more than one dome to the same transformer, it is important to wire the power con­nector in each dome the same way. That is, the wiring from one side of the transformer must be connected to the same connector on each dome.
WARNING: Make sure you wire power
DOME 1 POWER
to the outer connec­tors of the terminal block and ground to the middle connec-
DOME 2 POWER
tor. Otherwise, you could damage the dome.
DOME 3 POWER
14 Pelco Installation Manual C1487M-H (01/01)
Page 15
APPENDIX
Table A. Video Coaxial Cable Wiring Distances
Cable Type* Maximum Distance
RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor. 95% braided copper shield.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10­percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)
Wire Gauge
20 18 16 14 12 10
30 vA 94 ft 150 ft 238 ft 380 ft 603 ft 960 ft
(28 m) (45 m (115 m) (72 m) (183 m) (292 m)
75 vA 37 ft 60 ft 95 ft 152 ft 241 ft 384 ft
(11 m) (18 m) (29 m) (46 m) (73 m) (117 m)
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA per
dome for indoor models and 75 vA for outdoor models. Use a 24 VAC transformer with the following minimum vA:
40 vA per dome For indoor models (without heater) 100 vA per dome For outdoor models (with heater)
Table C. Switch Settings for SW1
Control Type Switch Setting
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
Coaxitron P-Type Control ON OFF OFF OFF OFF OFF OFF OFF** D-Type Control OFF ON OFF OFF OFF OFF OFF* OFF**
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
®
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex® controllers or with American Dynamics control systems using the AD2083 Translator. P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genex control systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
OFF OFF OFF OFF OFF OFF OFF OFF**
For CM9502 with fixed speed keyboards, set switch OFF.
Pelco Installation Manual C1487M-H (01/01) 15
Page 16
Table D. Switch Settings for SW2 – P-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For D-type control systems, refer to Table E.
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5
1 OFF OFF OFF OFF OFF 2ONOFF OFF OFF OFF 3 OFF ON OFF OFF OFF 4ONONOFF OFF OFF 5 OFF OFF ON OFF OFF 6ONOFF ON OFF OFF 7 OFF ON ON OFF OFF 8ONONONOFF OFF
9 OFF OFF OFF ON OFF 10 ON OFF OFF ON OFF 11 OFF ON OFF ON OFF 12 ON ON OFF ON OFF 13 OFF OFF ON ON OFF 14 ON OFF ON ON OFF 15 OFF ON ON ON OFF 16 ON ON ON ON OFF
Baud Rate Switch Setting
SW2-6 SW2-7 SW2-8
2400 OFF OFF OFF 4800 ON OFF OFF 9600 OFF ON OFF
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5
17 OFF OFF OFF OFF ON 18 ON OFF OFF OFF ON 19 OFF ON OFF OFF ON 20 ON ON OFF OFF ON 21 OFF OFF ON OFF ON 22 ON OFF ON OFF ON 23 OFF ON ON OFF ON 24 ON ON ON OFF ON 25 OFF OFF OFF ON ON 26 ON OFF OFF ON ON 27 OFF ON OFF ON ON 28 ON ON OFF ON ON 29 OFF OFF ON ON ON 30 ON OFF ON ON ON 31 OFF ON ON ON ON 32 ON ON ON ON ON
Table E. Switch Settings for SW2 – D-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For P-type control systems, refer to Table D.
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
1ONOFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3ONONOFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5ONOFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7ONONONOFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9ONOFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON ON OFF ON OFF OFF OFF 24 OFF OFF OFF ON ON OFF OFF OFF
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
25 ON OFF OFF ON ON OFF OFF OFF 26 OFF ON OFF ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON ON OFF OFF ON OFF OFF 39 ON ON ON OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF
(Continued on next page)
16 Pelco Installation Manual C1487M-H (01/01)
Page 17
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF OFF 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF OFF 64 OFF OFF OFF OFF OFF OFF ON OFF 65 ON OFF OFF OFF OFF OFF ON OFF 66 OFF ON OFF OFF OFF OFF ON OFF 67 ON ON OFF OFF OFF OFF ON OFF 68 OFF OFF ON OFF OFF OFF ON OFF 69 ON OFF ON OFF OFF OFF ON OFF 70 OFF ON ON OFF OFF OFF ON OFF 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON OFF 79 ON ON ON ON OFF OFF ON OFF 80 OFF OFF OFF OFF ON OFF ON OFF 81 ON OFF OFF OFF ON OFF ON OFF 82 OFF ON OFF OFF ON OFF ON OFF 83 ON ON OFF OFF ON OFF ON OFF 84 OFF OFF ON OFF ON OFF ON OFF 85 ON OFF ON OFF ON OFF ON OFF 86 OFF ON ON OFF ON OFF ON OFF 87 ON ON ON OFF ON OFF ON OFF 88 OFF OFF OFF ON ON OFF ON OFF 89 ON OFF OFF ON ON OFF ON OFF 90 OFF ON OFF ON ON OFF ON OFF 91 ON ON OFF ON ON OFF ON OFF 92 OFF OFF ON ON ON OFF ON OFF 93 ON OFF ON ON ON OFF ON OFF 94 OFF ON ON ON ON OFF ON OFF 95 ON ON ON ON ON OFF ON OFF 96 OFF OFF OFF OFF OFF ON ON OFF 97 ON OFF OFF OFF OFF ON ON OFF 98 OFF ON OFF OFF OFF ON ON OFF 99 ON ON OFF OFF OFF ON ON OFF
100 OFF OFF ON OFF OFF ON ON OFF 101 ON OFF ON OFF OFF ON ON OFF 102 OFF ON ON OFF OFF ON ON OFF 103 ON ON ON OFF OFF ON ON OFF 104 OFF OFF OFF ON OFF ON ON OFF
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
105 ON OFF OFF ON OFF ON ON OFF 106 OFF ON OFF ON OFF ON ON OFF 107 ON ON OFF ON OFF ON ON OFF 108 OFF OFF ON ON OFF ON ON OFF 109 ON OFF ON ON OFF ON ON OFF 110 OFF ON ON ON OFF ON ON OFF 111 ON ON ON ON OFF ON ON OFF 112 OFF OFF OFF OFF ON ON ON OFF 113 ON OFF OFF OFF ON ON ON OFF 114 OFF ON OFF OFF ON ON ON OFF 115 ON ON OFF OFF ON ON ON OFF 116 OFF OFF ON OFF ON ON ON OFF 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON ON OFF 121 ON OFF OFF ON ON ON ON OFF 122 OFF ON OFF ON ON ON ON OFF 123 ON ON OFF ON ON ON ON OFF 124 OFF OFF ON ON ON ON ON OFF 125 ON OFF ON ON ON ON ON OFF 126 OFF ON ON ON ON ON ON OFF 127 ON ON ON ON ON ON ON OFF 128 OFF OFF OFF OFF OFF OFF OFF ON 129 ON OFF OFF OFF OFF OFF OFF ON 130 OFF ON OFF OFF OFF OFF OFF ON 131 ON ON OFF OFF OFF OFF OFF ON 132 OFF OFF ON OFF OFF OFF OFF ON 133 ON OFF ON OFF OFF OFF OFF ON 134 OFF ON ON OFF OFF OFF OFF ON 135 ON ON ON OFF OFF OFF OFF ON 136 OFF OFF OFF ON OFF OFF OFF ON 137 ON OFF OFF ON OFF OFF OFF ON 138 OFF ON OFF ON OFF OFF OFF ON 139 ON ON OFF ON OFF OFF OFF ON 140 OFF OFF ON ON OFF OFF OFF ON 141 ON OFF ON ON OFF OFF OFF ON 142 OFF ON ON ON OFF OFF OFF ON 143 ON ON ON ON OFF OFF OFF ON 144 OFF OFF OFF OFF ON OFF OFF ON 145 ON OFF OFF OFF ON OFF OFF ON 146 OFF ON OFF OFF ON OFF OFF ON 147 ON ON OFF OFF ON OFF OFF ON 148 OFF OFF ON OFF ON OFF OFF ON 149 ON OFF ON OFF ON OFF OFF ON 150 OFF ON ON OFF ON OFF OFF ON 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 159 ON ON ON ON ON OFF OFF ON 160 OFF OFF OFF OFF OFF ON OFF ON
(Continued on next page)
Pelco Installation Manual C1487M-H (01/01) 17
Page 18
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON ON OFF OFF ON OFF ON 167 ON ON ON OFF OFF ON OFF ON 168 OFF OFF OFF ON OFF ON OFF ON 169 ON OFF OFF ON OFF ON OFF ON 170 OFF ON OFF ON OFF ON OFF ON 171 ON ON OFF ON OFF ON OFF ON 172 OFF OFF ON ON OFF ON OFF ON 173 ON OFF ON ON OFF ON OFF ON 174 OFF ON ON ON OFF ON OFF ON 175 ON ON ON ON OFF ON OFF ON 176 OFF OFF OFF OFF ON ON OFF ON 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OFF ON ON OFF ON 180 OFF OFF ON OFF ON ON OFF ON 181 ON OFF ON OFF ON ON OFF ON 182 OFF ON ON OFF ON ON OFF ON 183 ON ON ON OFF ON ON OFF ON 184 OFF OFF OFF ON ON ON OFF ON 185 ON OFF OFF ON ON ON OFF ON 186 OFF ON OFF ON ON ON OFF ON 187 ON ON OFF ON ON ON OFF ON 188 OFF OFF ON ON ON ON OFF ON 189 ON OFF ON ON ON ON OFF ON 190 OFF ON ON ON ON ON OFF ON 191 ON ON ON ON ON ON OFF ON 192 OFF OFF OFF OFF OFF OFF ON ON 193 ON OFF OFF OFF OFF OFF ON ON 194 OFF ON OFF OFF OFF OFF ON ON 195 ON ON OFF OFF OFF OFF ON ON 196 OFF OFF ON OFF OFF OFF ON ON 197 ON OFF ON OFF OFF OFF ON ON 198 OFF ON ON OFF OFF OFF ON ON 199 ON ON ON OFF OFF OFF ON ON 200 OFF OFF OFF ON OFF OFF ON ON 201 ON OFF OFF ON OFF OFF ON ON 202 OFF ON OFF ON OFF OFF ON ON 203 ON ON OFF ON OFF OFF ON ON 204 OFF OFF ON ON OFF OFF ON ON 205 ON OFF ON ON OFF OFF ON ON 206 OFF ON ON ON OFF OFF ON ON 207 ON ON ON ON OFF OFF ON ON 208 OFF OFF OFF OFF ON OFF ON ON
Receiver Switch Setting
Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
209 ON OFF OFF OFF ON OFF ON ON 210 OFF ON OFF OFF ON OFF ON ON 211 ON ON OFF OFF ON OFF ON ON 212 OFF OFF ON OFF ON OFF ON ON 213 ON OFF ON OFF ON OFF ON ON 214 OFF ON ON OFF ON OFF ON ON 215 ON ON ON OFF ON OFF ON ON 216 OFF OFF OFF ON ON OFF ON ON 217 ON OFF OFF ON ON OFF ON ON 218 OFF ON OFF ON ON OFF ON ON 219 ON ON OFF ON ON OFF ON ON 220 OFF OFF ON ON ON OFF ON ON 221 ON OFF ON ON ON OFF ON ON 222 OFF ON ON ON ON OFF ON ON 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON ON ON 235 ON ON OFF ON OFF ON ON ON 236 OFF OFF ON ON OFF ON ON ON 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF ON ON ON ON 243 ON ON OFF OFF ON ON ON ON 244 OFF OFF ON OFF ON ON ON ON 245 ON OFF ON OFF ON ON ON ON 246 OFF ON ON OFF ON ON ON ON 247 ON ON ON OFF ON ON ON ON 248 OFF OFF OFF ON ON ON ON ON 249 ON OFF OFF ON ON ON ON ON 250 OFF ON OFF ON ON ON ON ON 251 ON ON OFF ON ON ON ON ON 252 OFF OFF ON ON ON ON ON ON 253 ON OFF ON ON ON ON ON ON 254 OFF ON ON ON ON ON ON ON
18 Pelco Installation Manual C1487M-H (1/01)
Page 19
SPECIFICATIONS
MECHANICAL
Construction
Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic
Cable Entry
In-Ceiling: .75-inch (1.91 cm) conduit fitting Pendant: Through 1.5-inch (3.81 cm) NPT pendant mount
Pan Movement: 360° continuous pan rotation
Vertical Tilt: Unobstructed +2° to -92°
Manual Pan/Tilt Speeds*
Pan
Spectra II: 0.1°-80°/sec manual operation, 150°/sec turbo Spectra Lite: 0.5°-80°/sec manual operation, 150°/sec turbo
Tilt
Spectra II: 0.1°-40°/sec Spectra Lite: 0.5°-40°/sec
Preset Speeds
Pan: 250°/sec Tilt: 200°/sec
* For variable-speed operation an appropriate controller is required. With fixed-speed controllers, Spectra II and Spectra Lite pan/tilt
speed is 24°/sec. The CM6700 controller with the KBD200 keyboard has programmable fixed speeds.
ELECTRICAL
Input Voltage: 18-30 VAC, 24 VAC nominal
Input Power
In-ceiling: 30 vA Indoor pendant: 30 vA Outdoor pendant: 75 vA
Fuse: 1.6 A
Relay Contacts AUX 1 AUX 2 Output
Type: Form C Open collector transistor output Voltage: Low voltage (<40 V) 32 VDC maximum Current: 2 A maximum 150 mA maximum
GENERAL
Environment
In-Ceiling: Indoor only Pendant: Indoor/outdoor
Operating Range
In-Ceiling: 32° to 140°F (0° to 60°C) intermittent operation; 32° to 122°F (0° to 50°C) continuous operation Pendant
Without Heater: 32° to 140°F (0° to 60°C) absolute maximum operating temperature; 32° to 122°F (0° to 50°C) sustained
With Heater: (Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
maximum operating temperature
Maximum operating temperature: 140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum Minimum operating temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C) sustained minimum; prevents icing at -40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within 3 hours after power-up
Pelco Installation Manual C1487M-H (1/01) 19
Page 20
Dimensions: See Figure 1
Ratings: NEMA Type 1–In-ceiling back boxes, all dome drives
NEMA Type 4X–Pendant back boxes IP 66–Pendant back boxes
Weight Unit Shipping
In-Ceiling Back Box: 2.6 lb (1.18 kg) 4 lb (1.81 kg) Dome Drive: 2.65 lb (1.20 kg) 5 lb (2.27 kg) Lower Dome: .19 lb (.09 kg) 1 lb (.45 kg) Pendant Back Box: 2.85 lb (1.28 kg) 5 lb (2.27 kg)
Add 1.25 lbs (.57 kg) for heater and sun shield
Dome Drive: 2.65 lb (1.20 kg) 5 lb (2.27 kg) Lower Dome: 1.30 lb (.59 kg) 2.20 lb (1.0 kg)
Add .25 lbs (.11 kg) for heater
TOP PORTION OF BACK BOX IS REMOVABLE FOR SURFACE MOUNT APPLICATIONS
7.25 (18.13)
6.60 (16.76)
DOME IS SECURED TO CEILING BY MOUNTING BRACKET
8.52
(21.64)
5.25
13.34)
3.25
(8.26)
10.90
(27.69)
5.90 (14.99)
8.25 (20.96)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
5.90
(14.99)
Figure 1. SD5 Series Dimension Drawing
6.75
(17.15)
(14.80)
5.83
20 Pelco Installation Manual C1487M-H (1/01)
Page 21
CAMERAS
COLOR
Signal Format: NTSC (Spectra II dome drive models DD5BC, DD5BC22, and DD5BCBW)
Scanning System: 2:1 interlace
Image Sensor: 1/4-inch interline transfer CCD
Effective Pixels
Horizontal Resolution
Lens
Focal Length
(Spectra II and Spectra Lite)
PAL
(Spectra II dome drive models DD5BC-X, DD5BC22-X, and DD5BCBW-X)
NTSC (Spectra Lite dome drive model DD5TAC) PAL (Spectra Lite dome drive model DD5TAC-X)
NTSC Spectra II: 768 (H) x 494 (V) PAL Spectra II: 752 (H) x 582 (V)
NTSC Spectra Lite: 510 (H) x 492 (V)
PAL Spectra Lite: 500 (H) x 582 (V)
Spectra II: >470 TV lines Spectra Lite: 470 TVL (NTSC)
Minimum f-stop
Spectra II
16X: F1.4 18X: F1.4 22X: F1.6
Spectra Lite: F1.6
Spectra II
16X: 4 mm to 64 mm optical 18X: 4.1 mm to 73.8 mm optical 22X: 4 mm to 88 mm optical
Spectra Lite: 3.9 mm to 63 mm optical
460 TVL (PAL)
Zoom Ratio
Spectra II
16X: 16X optical zoom, 8X electronic zoom 18X: 18X optical zoom, 4X electronic zoom 22X: 22X optical zoom, 8X electronic zoom
Spectra Lite: 16 optical zoom
Digital Slow Shutter: Auto/manual speed selection
Horizontal Angle of View
Spectra II
16X: 47° (at 4 mm wide zoom),
18X: 48° (at 4.1 mm wide zoom),
22X: 47° (at 4 mm wide zoom),
Spectra Lite: 45° (at 3.9 mm wide zoom),
MTBF
16X: >2 million cycles at room temperature (zoom, focus, irs) 18X: >500,000 cycles at room temperature (zoom, focus, irs) 22X: >2 million cycles at room temperature (zoom, focus, irs) Spectra Lite: >1 million cycles at room temperature (zoom, focus, irs)
Focus: Automatic and manual override
3° (at 64 mm telephoto zoom)
2.7° (at 73.8 mm telephoto zoom)
2° (at 88 mm telephoto zoom)
3° (at 63 mm telephoto zoom)
Pelco Installation Manual C1487M-H (1/01) 21
Page 22
Sensitivity
Spectra II
16X: .05 lux at 1/2-second shutter speed 18X: .2 lux at 1/4-second shutter speed (color)
22X: .07 lux at 1/1.5-second shutter speed
Spectra Lite: 1 lux at f1.6 at signal level of 40 IRE, gain high (AGC on)
Sync System: AC line lock, phase adjustable via remote control*
White Balance: Automatic with manual override*
Shutter Speed Models
DD5BC, DD5BC22,
and DD5AM: 1/2-1/30,000*
DD5BC-X, DD5BC22-X,
and DD5AM-X: 1/1.5 to 1/30,000* DD5BCBW: 1/4 to 1/10,000* DD5BCBW-X: 1/3 to 1/10,000*
DD5TAC: 1/60 to 1/10,000*
DD5TAC-X: 1/50 to 1/10,000*
Iris Control
Spectra II: Automatic with manual override* Spectra Lite: Automatic with manual override*
Gain Control: Automatic with manual override*
Video Output
NTSC: .714V ± .07V (100 IRE ± 10 IRE) PAL: .7V ± .07V
.013 lux at 1/4-second shutter speed (black & white)
Signal to Noise Ratio: >46 dB
MONOCHROME
Signal Format: EIA (model DD5AM)
Scanning System: 2:1 interlace
Image Sensor: 1/4-inch interline transfer CCD
Horizontal Resolution: >500 TV lines
Effective Pixels
EIA: 768 (H) x 494 (V) CCIR: 752 (H) x 582 (V)
Lens
Minimum f-stop: F1.4 Focal Length: 4 mm to 64 mm optical Zoom Ratio: 16X optical zoom, 8X electronic zoom Horizontal Angle of View: 47° (at 4 mm wide zoom),
MTBF: >2 million cycles at room temperature (zoom, focus, iris) Focus: Automatic with manual override
Sensitivity
EIA: .1 lux at f1.4, AGC gain 26.5 dB, signal level 40 IRE, without IR cut filter CCIR: .1 lux at f1.4, AGC gain 29.5 dB, signal level 300 mV, without IR cut filter
(Spectra II Only)
CCIR (model DD5AM-X)
3° (at 64 mm telephoto zoom)
Signal Process: DSP-3R
Sync System: AC line lock, phase adjustable via remote control*
22 Pelco Installation Manual C1487M-H (1/01)
Page 23
Shutter Speed: Automatic (electronic iris)/manual
EIA: 1/60-1/30,000 CCIR: 1/50-1/30,000
Iris Control: Automatic with manual override*
Gain Control: Automatic with manual override*
Video Output
EIA: .714V ± .07V (100 IRE ± 10 IRE) CCIR: .7V ± .07V
Signal to Noise Ratio: >46 dB
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500, CM9760 and MPT9500 controllers, but not
with CM7500, MPT9000 or KBD9000 controllers.
(Design and product specifications subject to change without notice.)
CERTIFICATIONS AND REGULATORY NOTICES
CE, Class A (models DD5BC-X and DD5BC22-X). CE, Class B (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC-X, DD5AM-X, and DD5BCBW-X). (Model BB5A-PSG-E, Pending) UL/cUL (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, DD5AM, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC, DD5BC, DD5BC22, and DD5BCBW). (Model BB5A-PSG-E, Pending) FCC Class A (model DD5BC22) FCC Class B (models DD5AM, DD5BC, DD5TAC, and DD5BCBW).
Suitable for use in environmental air handling spaces (BB5A-F and BB5T-F).
FCC Class B meets more stringent requirements than FCC Class A.
The following applies to the DD5AM, DD5BC, and DD5TAC models.
FCC Class B - This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The following applies to the DD5BC22 model.
FCC Class A - This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Pelco Installation Manual C1487M-H (1/01) 23
Page 24
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
®
• Three years on Genex
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy fixed dome products.
•Two years on Spectra continuous motion applications.
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
Series products (multiplexers, server, and keyboard).
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
®
, Esprit®, ExSite™, and PS20 scanners, including when used in
®
and WW5700 Series window wiper (excluding wiper blades).
Series distributed network-based video products.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
REVISION HISTORY
Manual # Date Comments
C1487M 7/98 Original version.
C1487M-A 11/98 Revised the manual to incorporate Spectra Lite material. Added material on CCIR and EIA monochrome cameras, and PAL
C1487M-B 2/99 Changed Spectra Lite model numbers, and added comments that the line sync feature is not functional for the DD5T-C model
C1487M-C 7/99 Added a note relating to running patterns when an alarm activates. Changed the preset tilt speed from 100 to 200 degrees/
C1487M-D 7/99 Changed Spectra Lite camera zoom from 12X to 16X. Changed line sync and auto focus material to include Spectra Lite as
C1487M-E 9/99 Replaced the standard Spectra II DD5AC and DD5AC-X cameras with model DD5BC and DD5BC-X LowLight color cam-
C1487M-F 3/00 Separated into two manuals - Installation Manual and Operation and Programming Manual.
C1487M-G 5/00 Added information on Spectra II Color/Black and White.
C1487M-H 1/01 Added step to dome drive installation instructions referencing the new RS-422 termination switch. Revised specifications
® Pelco, the Pelco logo, Spectra, Genex, Legacy, and Coaxitron are registered trademarks of Pelco. © Copyright 2001, Pelco. All rights reserved. ™ Spectra II, Spectra Lite, Esprit, and Camclosure are trademarks of Pelco. U.S. Patent No. 5,931,432. ® Loctite is a registered trademark of Loctite Corporation.
color camera. Revised material in Section 5.11.21.2, Programming Limit Stops. Revised Section 6.0, Troubleshooting. Changed the fixed-speed controller rate in Section 8.0, Specifications.
of Spectra Lite. Changed power specifications for indoor models from 25 vA to 30 vA and for outdoor models from 90 vA to 75 vA. Revised maximum temperature operating ranges. Revised color camera specifications.
3/99 Changed auto iris material to include Spectra Lite as well as Spectra II.
second. Added model number and specifications for Spectra Lite PAL camera. Revised manual to new format.
well as Spectra II. Removed auto iris peak and auto sharpness options for Spectra Lite. Added white balance hue option for Spectra Lite and removed R-B and M-G white balance options for Spectra Lite. Revised Spectra Lite camera specifications.
eras. Added optional 176X color models. Revised main menu access documentation to include the KBD4000/KBD4002/ KBD4000V keyboards. Added material on LowLight limit. Revised material on shutter speed and zoom. Added material on zone overlap and priorities. Revised color camera specifications.
and certifications.
Loading...