IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................... 4
HARD CEILING INSTALLATION .................................................................................................................................... 6
CERTIFICATIONS AND REGULATORY NOTICES .......................................................................................................23
WARRANTY AND RETURN INFORMATION ........................................................................................................................24
LIST OF ILLUSTRATIONS
FigurePage
1SD5 Series Dimension Drawing ............................................................................................................................20
CSwitch Settings for SW1 ........................................................................................................................................ 15
DSwitch Settings for SW2 – P-Type Control ............................................................................................................ 16
ESwitch Settings for SW2 – D-Type Control ............................................................................................................ 16
Pelco Installation Manual C1487M-H (1/01)3
Page 4
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it
must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to
verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and
lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present within
this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
MEASURES DE SECURITE IMPORTANTES
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et conformes au codes locaux.
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4, 4X, 6 ou 6P, il est uniquement conçu pour
utilisation intérieure et ne peut donc pas être en contact de pluie ou d’humidité.
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.
4. Après toute installation ou réparation de la partie électrique de ce produit, une résistance entre le courant et la partie exposée devrait
être installée afin de vérifier que la partie électrique n’aie pas été en contact d’un court circuit.
5. L’installation entreprise et le matériel utilisé devraient supporter quatre fois le poids du boitié, de la tourelle, de la caméra, et de la
lentille.
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:
Ce symbol indique qu’un voltage dangereux
pouvant provoquer un chock électrique est
présant dans cette unité.
RISQUE DE CHOQUE ÉLECTRIQUE.
Ce symbol indique qu’il y a des mesures
d’installation et d’entretient importantes
inclus dans le manuel de cet équipement.
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute installation.
CAUTION:
NE PAS OUVRIR.
4Pelco Installation Manual C1487M-H (1/01)
Page 5
INSTALLATION
The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes. Inspect each box to make sure all parts are
present.
1 Acrylic lower dome with trim ring
1 Parts bag (O-ring and lubricant, and tube of Loctite)
BACK BOX
DOME DRIVE
DOME DRIVE
LOWER DOME
COMPASS TOOL
SAFETY BRACKET
T-RAIL CLIP
CONDUIT FITTING & LOCK NUT
LOWER DOME
THREAD
COMPOUND
LOCTITE®
222MS
O-RING
LUBE
O-RING
Pelco Installation Manual C1487M-H (1/01)5
Page 6
HARD CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING
a. Locate the center point of the mounting location. Drill a hole in
the ceiling using a 3/32-inch drill. Insert the compass tool into
the hole.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up
to 16 pounds (7.3 kg).
b. Draw a circle on the ceiling using the compass tool and a
pencil. Cut the circle out of the ceiling.
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting.
Refer to Tables A and B in the Appendix for wiring distances.
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until
you hear a clicking noise.
6Pelco Installation Manual C1487M-H (1/01)
Page 7
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
d. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
Trouble-
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
LABEL
SW2
COAXITRON
CONTROLLER
2 WIRE
CONTROLLER
SPECTRA II ONLY
+5 to +24 VDC
LOGIC GATE
(WIRING EXAMPLE)
EXTERNAL RELAY
(WIRING EXAMPLE)
CONTROLLER
VIDEO IN
+5 VDC
GREEN
TAB
TXTX+
NOT USED
NOT USED
SWITCHES
(WIRING EXAMPLE)
AUX 2
RED
TAB
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TXTX+
1
2
ALARM
3
INPUTS
4
5
6
7
GROUND
(NO)
(NC)
GROUND
HEATER/FAN
(NOT USED)
RELAY
(AUX 1)
AUX 2
RS-422 TERMINATION SWITCH
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appendix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the
mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
Pelco Installation Manual C1487M-H (1/01)7
Page 8
SUSPENDED CEILING INSTALLATION
IN-CEILING MODELS
STEP 1 - PREPARE CEILING TILE
NOTE: The ceiling tile cannot be thinner than 0.50-inch (1.27 cm) or thicker than 1.75-inches (4.45 cm).
a. Remove the ceiling tile from the ceiling. Insert the compass tool (supplied) into the center of the tile. (If necessary use a 3/32-inch bit
to drill a hole.)
b. Draw a circle on the tile using the compass tool and a pencil. Cut the circle out of the ceiling tile.
STEP 2 - INSTALL THE BACK BOX
ATTACH SAFETY CHAIN HERE
a. Attach the conduit fitting, lock nut, and safety chain bracket.
Install a safety chain/cable (not supplied) that will support up
to 16 pounds (7.3 kg).
CEILING TILE
b. Turn the thumb screw and open the hinged door to the back
box. Pull wiring into the back box through the conduit fitting.
Refer to Tables A and B in the Appendix for wiring distances.
T-RAIL CLIP
FOR
T-RAIL CLIP
FOR
CEILING TILE
CEILING TILE
c. Compress the spring clips on the back box and push it through
the hole, until the clips spring back. Tighten the screws until
you hear a clicking noise.
d. Install the ceiling tile with the back box. Attach a T-rail clip on
each side of the ceiling tile. Fasten the L-bracket to the clip
with the supplied screw and washers.
8Pelco Installation Manual C1487M-H (1/01)
Page 9
e. Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
Trouble-
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
COAXITRON
CONTROLLER
2 WIRE
CONTROLLER
+5 to +24 VDC
(WIRING EXAMPLE)
CONTROLLER
SPECTRA II ONLY
LOGIC GATE
24 VAC
TRANFORMER
VIDEO IN
TXTX+
(WIRING EXAMPLE)
+5 VDC
NOT USED
NOT USED
SWITCHES
POWER
(24 VAC ONLY)
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TXTX+
1
2
ALARM
3
INPUTS
4
5
6
7
GROUND
(NO)
(NC)
GROUND
RELAY
(AUX 1)
AUX 2
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appendix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
RED
TAB
HEATER/FAN
(NOT USED)
EXTERNAL RELAY
(WIRING EXAMPLE)
GREEN
TAB
AUX 2
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
STEP 4 - INSTALL LOWER DOME
a. Snap the clip, on the end of the trim ring leash, into the hole on the
lip of the back box.
b. Line up the snaps on the trim ring with the mounting screws on the
back box. Snap the trim ring into the plastic snap washers on the
mounting screws.
TO USE YOUR DOME, REFER TO THE
OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)9
Page 10
PENDANT-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - MOUNT AND INSTALL THE BACK BOX
NOTE: If installing outdoors make sure the installation is properly sealed to keep moisture out.
a. Install the mount for the pendant dome. Refer to the instruc-
tions supplied with the mount. Bring the wiring for the dome
b. Turn the thumbscrew and open the hinged door located inside
the back box.
through the mount. Refer to Tables A and B in the Appendix for
wiring distances.
c. Pull wiring from the mount into the back box.d. Screw the back box into the mount. If outdoors, apply thread
compound (provided) to the threads on the back box.
STEP 2 - WIRE CIRCUIT BOARD
Attach the wiring to the interconnect circuit board inside the back
box. Close the door to the back box. Turn on power to the back
box. The red LED will light.
IMPORTANT: If the LED does not light, refer to the Troubleshooting section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
COAXITRON
CONTROLLER
2 WIRE
CONTROLLER
+5 to +24 VDC
(WIRING EXAMPLE)
CONTROLLER
SPECTRA II ONLY
LOGIC GATE
24 VAC
TRANFORMER
VIDEO IN
TXTX+
(WIRING EXAMPLE)
+5 VDC
NOT USED
NOT USED
SWITCHES
POWER
(24 VAC ONLY)
VIDEO OUT
RX-
CONTROL
RX+
TXTX+
1
2
ALARM
3
INPUTS
4
5
6
7
GROUND
(NO)
(NC)
GROUND
(RS-422)
RELAY
(AUX 1)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
AUX 2
HEATER/FAN
(NOT USED)
10Pelco Installation Manual C1487M-H (1/01)
Page 11
STEP 3 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or tables C through E in the Appendix
in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 4 - INSTALL LOWER DOME
RED
GREEN
TAB
TAB
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
NOTE: If you are installing an outdoor model,
plug the two-pin heater
connection in the lower
dome into the mating
connector in the back
box.
LEASH
ATTACH
LEASH TO
NEAREST
RETAINER
SCREW
MOUNTING
SCREW HOLES
FRONT & BACK
b. Attach the back box trim leash to the lower dome. Use retainer
screw (nearest to a mounting screw) inside lower dome.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite 222MS (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)11
Page 12
SURFACE-MOUNT INSTALLATION
PENDANT MODELS
STEP 1 - REMOVE THE TOP PORTION OF THE BACK BOX
a. Turn the thumbscrew and open the
hinged door located inside the back box.
b. Unscrew the three Phillips screws lo-
cated underneath the hinged door.
c. Remove the top portion of the back box.
STEP 2 - PREPARE SURFACE AND INSTALL THE BACK BOX
NOTE: If installing outdoors
apply a sealant between the
back box and the mounting
surface
a. Determine the mounting location. Use the base of the back box as a template. Mark the fastener and center hole positions onto the
mounting surface.
b. Drill a hole in the center of the mounting surface. Pull wiring through the opening. Refer to Tables A and B in the Appendix for wiring
distances. Prepare the holes for the fasteners. Position the back box over the mounting holes and pull wiring into the back box.
Secure the back box to the mounting surface using the appropriate hardware for your installation.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
STEP 3 - WIRE CIRCUIT BOARD
Attach the wiring to the interconnect circuit board inside the back
box. Close the door to the back box. Turn on power to the back
box. The red LED will light.
IMPORTANT: If the LED does not light, refer to the
shooting
section.
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
Trouble-
COAXITRON
CONTROLLER
2 WIRE
CONTROLLER
SPECTRA II ONLY
+5 to +24 VDC
LOGIC GATE
(WIRING EXAMPLE)
EXTERNAL RELAY
(WIRING EXAMPLE)
CONTROLLER
VIDEO IN
TXTX+
+5 VDC
NOT USED
NOT USED
SWITCHES
(WIRING EXAMPLE)
AUX 2
VIDEO OUT
RX-
CONTROL
RX+
(RS-422)
TXTX+
1
2
ALARM
3
INPUTS
4
5
6
7
GROUND
(NO)
(NC)
GROUND
HEATER/FAN
(NOT USED)
RELAY
(AUX 1)
AUX 2
12Pelco Installation Manual C1487M-H (1/01)
Page 13
STEP 4 - INSTALL DOME DRIVE
SW1
ON
123
6
4
5
78
ON
SW2
1
3
2
4
5
6
8
7
SW2
LABEL
SW1
RS-422 TERMINATION SWITCH
LABEL
SW2
00303
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive or Tables C through E in the Appendix in the back of this manual.
b. Daisy Chain Operation Only – When connecting more than
one Spectra dome system to a single controller, terminate the
STEP 5 - INSTALL LOWER DOME
RED
GREEN
TAB
TAB
last unit in the chain (farthest from the controller). To terminate
the dome drive set the RS-422 termination switch to the left.
c. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
a. Lightly apply O-ring lubricant to the O-ring. Install the O-ring in
the groove on the trim ring of the lower dome.
NOTE: If you are installing an outdoor model,
plug the two-pin heater
connection in the lower
dome into the mating
connector in the back
box.
LEASH
ATTACH
LEASH TO
NEAREST
RETAINER
SCREW
MOUNTING
SCREW HOLES
FRONT & BACK
b. Attach the back box trim leash to the lower dome. Use the
retainer screw (nearest to a mounting screw) inside lower dome.
c. Remove the two lower dome, mounting screws. Apply a drop
of Loctite (supplied) to each screw.
d. Push the lower dome inside the back box, line up the mounting
screw holes, and install the two mounting screws.
TO USE YOUR DOME, REFER TO THE OPERATION AND PROGRAMMING MANUAL.
Pelco Installation Manual C1487M-H (1/01)13
Page 14
TROUBLESHOOTING
PROBLEMPOSSIBLE CAUSESOLUTION
Unit does not operate.
The controller is not
communicating with the
Spectra unit.
Check to see if the red LED on the circuit
board in the back box is lit.
1. The red LED is not lit.
a. Fuse is bad.
b. 24 VAC power source is not con-
nected or back box is bad.
2. The red LED is lit.
a. Wiring is incorrect or is not fully
seated.
b. DIP switch settings are incorrect.
a. Check fuse on the circuit board. Replace fuse if
it is bad. To order a fuse from Pelco, specify the
part number FUS1.6-5X20FAST. This is a 1.6ampere fuse, 5 x 20 mm, fast blow.
b. Use a voltmeter to check if 24 VAC is getting to
the power connector on the circuit board. If NO,
check your power supply. If YES, return the back
box to the factory for repair.
a. Check all connections to the circuit board.
Make sure that all connections are fully seated
and the board is wired correctly.
b. Check the DIP switch settings on the dome
drive (refer to Tables C, D, and E). If the unit still
does not operate, turn off power and replace
the dome drive with a good unit, if you have a
spare. Check the switch settings on the substitute dome drive before installing it. (If you do not
have a spare, return the dome drive and back
box to the factory.) If you substituted a dome
drive and the unit operates, the original
dome drive is bad (return the dome drive to the
factory). If the unit still does not operate,
then the circuit board is bad (return the back
box to the factory).
Fan does not operate.
Fan connections are not fully seated.
Make sure the connector for the fan is fully seated.
If the fan still does not operate, return the back box
and dome drive to the factory for repair.
Vertical roll on monitor
when switching between
cameras.
Cameras are out of phase.
If you are wiring more than one dome to the same
transformer, it is important to wire the power connector in each dome the same way. That is, the
wiring from one side of the transformer must be
connected to the same connector on each dome.
WARNING: Make
sure you wire power
DOME 1
POWER
to the outer connectors of the terminal
block and ground to
the middle connec-
DOME 2
POWER
tor. Otherwise, you
could damage the
dome.
DOME 3
POWER
14Pelco Installation Manual C1487M-H (01/01)
Page 15
APPENDIX
Table A. Video Coaxial Cable Wiring Distances
Cable Type*Maximum Distance
RG59/U750 ft (229 m)
RG6/U1,000 ft (305 m)
RG11/U1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor.
95% braided copper shield.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10percent voltage drop. (Ten percent is generally the maximum allowable voltage
drop for AC-powered devices.)
Wire Gauge
201816141210
30 vA94 ft150 ft238 ft380 ft603 ft960 ft
(28 m)(45 m(115 m) (72 m)(183 m) (292 m)
75 vA37 ft60 ft95 ft152 ft241 ft384 ft
(11 m)(18 m)(29 m)(46 m)(73 m)(117 m)
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA per
dome for indoor models and 75 vA for outdoor models.
Use a 24 VAC transformer with the following minimum vA:
40 vA per domeFor indoor models (without heater)
100 vA per domeFor outdoor models (with heater)
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
®
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex® controllers or with
American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genex control systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
OFFOFFOFFOFFOFFOFFOFFOFF**
For CM9502 with fixed speed keyboards, set switch OFF.
Pelco Installation Manual C1487M-H (01/01)15
Page 16
Table D. Switch Settings for SW2 – P-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For D-type control systems, refer to Table E.
* For variable-speed operation an appropriate controller is required. With fixed-speed controllers, Spectra II and Spectra Lite pan/tilt
speed is 24°/sec. The CM6700 controller with the KBD200 keyboard has programmable fixed speeds.
ELECTRICAL
Input Voltage:18-30 VAC, 24 VAC nominal
Input Power
In-ceiling:30 vA
Indoor pendant:30 vA
Outdoor pendant:75 vA
Fuse: 1.6 A
Relay ContactsAUX 1AUX 2 Output
Type:Form COpen collector transistor output
Voltage:Low voltage (<40 V)32 VDC maximum
Current:2 A maximum150 mA maximum
GENERAL
Environment
In-Ceiling:Indoor only
Pendant:Indoor/outdoor
Operating Range
In-Ceiling:32° to 140°F (0° to 60°C) intermittent operation; 32° to 122°F (0° to 50°C) continuous operation
Pendant
Without Heater:32° to 140°F (0° to 60°C) absolute maximum operating temperature; 32° to 122°F (0° to 50°C) sustained
With Heater:(Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
maximum operating temperature
Maximum operating temperature: 140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum
Minimum operating temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C)
sustained minimum; prevents icing at -40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within 3
hours after power-up
Pelco Installation Manual C1487M-H (1/01)19
Page 20
Dimensions:See Figure 1
Ratings:NEMA Type 1–In-ceiling back boxes, all dome drives
NEMA Type 4X–Pendant back boxes
IP 66–Pendant back boxes
WeightUnitShipping
In-Ceiling
Back Box:2.6 lb (1.18 kg)4 lb (1.81 kg)
Dome Drive:2.65 lb (1.20 kg)5 lb (2.27 kg)
Lower Dome:.19 lb (.09 kg)1 lb (.45 kg)
Pendant
Back Box:2.85 lb (1.28 kg)5 lb (2.27 kg)
Add 1.25 lbs (.57 kg) for heater and sun shield
Dome Drive:2.65 lb (1.20 kg)5 lb (2.27 kg)
Lower Dome:1.30 lb (.59 kg)2.20 lb (1.0 kg)
Add .25 lbs (.11 kg) for heater
TOP PORTION OF BACK BOX
IS REMOVABLE FOR SURFACE
MOUNT APPLICATIONS
7.25 (18.13)
6.60 (16.76)
DOME IS SECURED
TO CEILING BY
MOUNTING BRACKET
8.52
(21.64)
5.25
13.34)
3.25
(8.26)
10.90
(27.69)
5.90 (14.99)
8.25 (20.96)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
5.90
(14.99)
Figure 1. SD5 Series Dimension Drawing
6.75
(17.15)
(14.80)
5.83
20Pelco Installation Manual C1487M-H (1/01)
Page 21
CAMERAS
COLOR
Signal Format:NTSC (Spectra II dome drive models DD5BC, DD5BC22, and DD5BCBW)
Scanning System:2:1 interlace
Image Sensor:1/4-inch interline transfer CCD
Effective Pixels
Horizontal Resolution
Lens
Focal Length
(Spectra II and Spectra Lite)
PAL
(Spectra II dome drive models DD5BC-X, DD5BC22-X, and DD5BCBW-X)
NTSC (Spectra Lite dome drive model DD5TAC)
PAL (Spectra Lite dome drive model DD5TAC-X)
NTSC Spectra II:768 (H) x 494 (V)
PAL Spectra II:752 (H) x 582 (V)
NTSC Spectra Lite:510 (H) x 492 (V)
PAL Spectra Lite:500 (H) x 582 (V)
Spectra II:>470 TV lines
Spectra Lite:470 TVL (NTSC)
Minimum f-stop
Spectra II
16X:F1.4
18X:F1.4
22X:F1.6
Spectra Lite:F1.6
Spectra II
16X:4 mm to 64 mm optical
18X:4.1 mm to 73.8 mm optical
22X:4 mm to 88 mm optical
16X:>2 million cycles at room temperature (zoom, focus, irs)
18X:>500,000 cycles at room temperature (zoom, focus, irs)
22X:>2 million cycles at room temperature (zoom, focus, irs)
Spectra Lite:>1 million cycles at room temperature (zoom, focus, irs)
Focus:Automatic and manual override
3° (at 64 mm telephoto zoom)
2.7° (at 73.8 mm telephoto zoom)
2° (at 88 mm telephoto zoom)
3° (at 63 mm telephoto zoom)
Pelco Installation Manual C1487M-H (1/01)21
Page 22
Sensitivity
Spectra II
16X:.05 lux at 1/2-second shutter speed
18X:.2 lux at 1/4-second shutter speed (color)
22X:.07 lux at 1/1.5-second shutter speed
Spectra Lite:1 lux at f1.6 at signal level of 40 IRE, gain high (AGC on)
Sync System:AC line lock, phase adjustable via remote control*
White Balance:Automatic with manual override*
Shutter Speed Models
DD5BC, DD5BC22,
and DD5AM:1/2-1/30,000*
DD5BC-X, DD5BC22-X,
and DD5AM-X:1/1.5 to 1/30,000*
DD5BCBW:1/4 to 1/10,000*
DD5BCBW-X:1/3 to 1/10,000*
DD5TAC:1/60 to 1/10,000*
DD5TAC-X:1/50 to 1/10,000*
Iris Control
Spectra II:Automatic with manual override*
Spectra Lite:Automatic with manual override*
.013 lux at 1/4-second shutter speed (black & white)
Signal to Noise Ratio:>46 dB
MONOCHROME
Signal Format:EIA (model DD5AM)
Scanning System:2:1 interlace
Image Sensor:1/4-inch interline transfer CCD
Horizontal
Resolution:>500 TV lines
Effective Pixels
EIA:768 (H) x 494 (V)
CCIR:752 (H) x 582 (V)
Lens
Minimum f-stop:F1.4
Focal Length:4 mm to 64 mm optical
Zoom Ratio:16X optical zoom, 8X electronic zoom
Horizontal
Angle of View:47° (at 4 mm wide zoom),
MTBF:>2 million cycles at room temperature (zoom, focus, iris)
Focus:Automatic with manual override
Sensitivity
EIA:.1 lux at f1.4, AGC gain 26.5 dB, signal level 40 IRE, without IR cut filter
CCIR:.1 lux at f1.4, AGC gain 29.5 dB, signal level 300 mV, without IR cut filter
(Spectra II Only)
CCIR (model DD5AM-X)
3° (at 64 mm telephoto zoom)
Signal Process:DSP-3R
Sync System:AC line lock, phase adjustable via remote control*
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500, CM9760 and MPT9500 controllers, but not
with CM7500, MPT9000 or KBD9000 controllers.
(Design and product specifications subject to change without notice.)
CERTIFICATIONS AND REGULATORY NOTICES
CE, Class A (models DD5BC-X and DD5BC22-X).
CE, Class B (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC-X, DD5AM-X,
and DD5BCBW-X). (Model BB5A-PSG-E, Pending)
UL/cUL (models BB5A-F, BB5A-PB, BB5A-PG, BB5A-PG-E, DD5AM, BB5T-F, BB5T-PB, BB5T-PG, BB5T-PG-E, DD5TAC, DD5BC,
DD5BC22, and DD5BCBW). (Model BB5A-PSG-E, Pending)
FCC Class A (model DD5BC22)
FCC Class B (models DD5AM, DD5BC, DD5TAC, and DD5BCBW).
Suitable for use in environmental air handling spaces (BB5A-F and BB5T-F).
FCC Class B meets more stringent requirements than FCC Class A.
The following applies to the DD5AM, DD5BC, and DD5TAC models.
FCC Class B - This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The following applies to the DD5BC22 model.
FCC Class A - This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
Pelco Installation Manual C1487M-H (1/01)23
Page 24
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
®
• Three years on Genex
• Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy
fixed dome products.
•Two years on Spectra
continuous motion applications.
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Series products (multiplexers, server, and keyboard).
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
®
, Esprit®, ExSite™, and PS20 scanners, including when used in
®
and WW5700 Series window wiper (excluding wiper blades).
™
Series distributed network-based video products.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual # Date Comments
C1487M7/98Original version.
C1487M-A 11/98 Revised the manual to incorporate Spectra Lite material. Added material on CCIR and EIA monochrome cameras, and PAL
C1487M-B 2/99Changed Spectra Lite model numbers, and added comments that the line sync feature is not functional for the DD5T-C model
C1487M-C 7/99Added a note relating to running patterns when an alarm activates. Changed the preset tilt speed from 100 to 200 degrees/
C1487M-D 7/99Changed Spectra Lite camera zoom from 12X to 16X. Changed line sync and auto focus material to include Spectra Lite as
C1487M-E 9/99Replaced the standard Spectra II DD5AC and DD5AC-X cameras with model DD5BC and DD5BC-X LowLight color cam-
C1487M-F 3/00Separated into two manuals - Installation Manual and Operation and Programming Manual.
C1487M-G 5/00Added information on Spectra II Color/Black and White.
C1487M-H 1/01Added step to dome drive installation instructions referencing the new RS-422 termination switch. Revised specifications
color camera. Revised material in Section 5.11.21.2, Programming Limit Stops. Revised Section 6.0, Troubleshooting. Changed
the fixed-speed controller rate in Section 8.0, Specifications.
of Spectra Lite. Changed power specifications for indoor models from 25 vA to 30 vA and for outdoor models from 90 vA to
75 vA. Revised maximum temperature operating ranges. Revised color camera specifications.
3/99Changed auto iris material to include Spectra Lite as well as Spectra II.
second. Added model number and specifications for Spectra Lite PAL camera. Revised manual to new format.
well as Spectra II. Removed auto iris peak and auto sharpness options for Spectra Lite. Added white balance hue option for
Spectra Lite and removed R-B and M-G white balance options for Spectra Lite. Revised Spectra Lite camera specifications.
eras. Added optional 176X color models. Revised main menu access documentation to include the KBD4000/KBD4002/
KBD4000V keyboards. Added material on LowLight limit. Revised material on shutter speed and zoom. Added material on
zone overlap and priorities. Revised color camera specifications.
and certifications.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.