1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be
observed.
2. Only use replacement parts recommended by Pelco.
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
1.1 UNPACKING Unpack and inspect all parts carefully. INSTRUCTIONS
The following items are supplied:
1Window defroster 1 C1421M-B Installation/Operation Manual
Be sure to save the shipping carton and any inserts. They are the safest materials in which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its carton and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement. (International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY AND RETURN section of this manual for instructions.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
1.2 RECOMMENDED TOOLS Pelco does not supply basic tools needed for the installation process. The following
tools are recommended:
Phillips screwdriver Flat screwdriver
2.0 DESCRIPTION The WD35 Series Defroster Kits are continuous duty defroster kits for use with the
EH3500 Series Enclosures.
2.1 MODELS WD35-1 Window defroster kit, 120 VAC, 3 watts
WD35-2 Window defroster kit, 24 VAC, 3 watts WD35-3 Window defroster kit, 230 VAC, 3 watts
2.2 CERTIFICATIONS The products identified below have been tested and certified for agency compli-
ance as noted.
Agency Complance Certification
Model CE FCC UL CSA/cUL
WD35-2 X
WD35-3 X
3.0 INSTALLATION To install the WD35 Series Window Defroster Kit, perform the following steps (see
Figure 1):
1. Disconnect the enclosure from all sources of power and open the enclosure lid.
2. Remove the camera and sled.
3. Loosen the screws in the bottom window bracket.
4. Remove the top window bracket.
NOTE:
Window defrosters manu­factured after July 1998 have a metal plate affixed to the defroster.
NOTE:
When a window defroster and blower are both used, the two accessories will share the same terminal locations on the PCB.
5. Position the window defroster with the metal plate against the inside face of the window. Make sure the defroster wires are in the lower left corner of the window.
6. Reinstall the top window bracket.
7. Tighten the bottom window bracket screws.
8. Route the defroster wires between the track rail and the body of the enclosure. Attach the window defroster wires to the PCB terminal locations as shown in Figure 2. Make sure the window defroster wires are not obstructing any other accessories within the enclosure.
9. Reinstall the camera and sled.
10. Close the enclosure lid and reconnect power to the enclosure.