Pelco C1005M-G User Manual

INSTALLATION/OPERATION
ICI1000PIM Personality Interface
®
Module
C1005M-G (10/02)
GENERAL
DESCRIPTION
Unpack and inspect all parts carefully.
The following items are supplied:
1 ICI1000PIM Personality Interface Module 1 RJ-14 cable for Inter-Check® and the DX2000 DVR 1 RJ-45 coupler for the DX2000 DVR
The ICI1000PIM Personality Interface Module (PIM) is a data protocol translator that translates data from cash registers and other devices for use with Pelco’s Inter-Check or DX2000 Digital Video Recorder (DVR).
Inter-Check is an automatic text insertion system that displays the data on a CCTV monitor. The DX2000 records video and transaction data and lets the user view video and its associated data (if applicable) on a PC (personal computer).
2 C1005M-G (10/02)
INSTALLATION
NOTE: The information in this manual is for PIM software version 4.02 and above.
INSTALLATION FOR INTER-CHECK
Refer to the ICI1000S Inter-Check manual as you install the ICI1000PIM.
1. Configure DIP switch bank 1 on the PIM (refer to
2. Configure DIP switch bank 2 on the PIM (refer to
Configuring DIP Switch Bank 1
Configuring DIP Switch Bank 2
section).
section).
3. Locate the 16-pin connector on your register/interface. Plug the register/interface connector into the PIM.
4. Plug one data cable connector into the data connector in the PIM.
5. Connect the other end of the data cable in one of the following ways.
a. If the Inter-Check and the PIM are within 6 feet (1.8 m) of each other, modify the cable as follows:
Refer to Figure 1 and slit the jacket to expose the wires.
Cut the red and green wires. To ensure the cut wires will not contact each other, either remove a section of the red and green wires or, in case you want to reconnect the wires later, tape one end of the cut wires.
Plug the cable into the Inter-Check.
b. If the Inter-Check and the PIM are more than 6 feet (1.8 m) apart, you must use the wiring kit. Refer to Figure 2. The
wiring kit is supplied with the ICI1000SE and ICI1000SI.
6. Mount the PIM inside or near the cash register or other device. Depending on the application, you may need to use double-sided tape to secure the ICI1000PIM to the mount location.
7. Power-up the Inter-Check. To set all Inter-Check communication parameters to the specific values needed to communicate with the ICI1000PIM module, do the following:
a. Enter the main screen by pressing the ESC key and then the ENT key on the keypad.
b. Once the main screen is present, press the #6 key selection (Diagnostics) and then the #8 key ([DL] PIM Default
Load).
c. Press the #8 key until the loaded message appears on the screen, and then press the ESC key until the unit is
reinitialized.
(Refer to the C1000M-B manual if more detailed information on this procedure is required.)
8. Power-up the register or other device.
9. Connect the power plug into the PIM and plug the wall mount transformer into power. This will power up the PIM.
10. Upon PIM power up, you should see a prompt that matches your register/ interface type displayed on the monitor. A PIM version number will also be
SLIT JACKET TO EXPOSE WIRES
CUT RED AND GREEN WIRES
displayed. If this prompt appears on the monitor, the Inter-Check and the PIM are communicating properly.
Figure 1. Cable Modification
C1005M-G (10/02) 3
STRAIGHT-THROUGH PHONE CABLE
USER-SUPPLIED CABLE, 18 AWG, SHIELDED WIRE IS SUGGESTED
WHITE BLUE
BLACK YELLOW
RED GREEN
TO INTER-CHECK UNIT
FROM ICI1000PIM
WHITE BLUE
BLACK YELLOW
RED GREEN
Figure 2. Configuration for Wiring ICI1000PIM Module
4 C1005M-G (10/02)
Loading...
+ 8 hidden pages