= Vertical bar in left or right margin indicates change or addition.
®
BK4000/BK4024/BK4220 Series
Blower Kit
Installation/Operation
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2. Unless the unit is specifically marked as a NEMA
Type 3-6P enclosure, it is designed for Indoor use
only and it must not be installed where exposed to
rain and moisture.
4. Only use replacement parts recommended by
PELCO.
Manual C436M-B (12/94)
2.0 SCOPE
The information contained within this manual covers
the installation and operation of the BK4000/BK4024/
BK4220 Blower Kits. Please familiarize yourself with
the information in this manual prior to installation and
operation.
2.1 DESCRIPTION
The BK4000/BK4024/BK4220 Blower Kits are engineered for installation in the EH4014 and EH4018 Enclosures. The BK4000 requires 120 VAC, the BK4024
requires 24 VAC, and the BK4220 requires 230 VAC.
All units can be used in conjunction with the corresponding Heater Kit.
BK4000 requires 4 watts at 120 VAC, 60 Hz.
BK4024 requires 3 watts at 24 VAC, 60 Hz. (CE)
BK4220 requires 4.8 watts at 230 VAC, 60Hz. (CE)
NOTE: Once installed, the blower kit will reduce
the maximum camera/lens length specified by 13/4 inches.
PELCO • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827 • DataFAX (800) 289-9108 or (1-559) 292-0435
3.0 INSTALLATION
The BK4000/BK4024/BK4220 Blower Kits are supplied with the following installation parts:
QTY ITEM
1. Remove the Phillips Head screws from the rear cap
and slide the assembly out from the enclosure.
2. Attach the blower assembly to the rear plate using
two of the self-tapping screws, holding the end
cap to the sled.
1 Blower
1 Blower Bracket
To install the BK4000/BK4024/BK4220 perform the
following steps (refer to Figure 1):
3.1 PARTS LIST (Figure 1.)
Item Qty Description Part Number
1 1 Bracket, fan/pc board BK40004000COMP
2 1 Bracket component, 24VAC, 230VAC BK7044002COMP
1 PCB assy, term/thermott, (used with heater kit) PCB9000300ASSY
3 1 Fan, 2.36-inch Sq., 120/230 VAC MM750010003
1 Fan, 2.36-inch Sq., 24VDC ED210005
4 1 Resistor 3k ohm, 10w (230 VAC blowerkit only) RES003.0K10.0
1 Diode Bridge Rect, 1A400PRV (24 VAC only) DIOMDA104
5 1 Insulator, PC board (heater kit only) BK400010000
A 4 Washer, nylon ZH200X437X62N
B 4 Screw, 6-32 x 3/8 pan phil SS ZH6-32X.375SPP
C 2 Screw, 6-32 x 1.5 pan phil SS ZH6-32X1.50SPP
D 2 Nut, hex, 6-32 ZH6-323NUTSH
E 2 Screw, 6-32 x 1/4 self tapping phil ZH6-SFX.250SPP
F 8 Internal tooth lockwasher, #6 ZH6LWSIS
3. Wire according to the wiring diagram in Figure 2.
NOTE: When used with a heater kit (and
PCB), the blower can be wired into the terminal block on the PC Board (see Figure 2). With
the blower kit only, the PCB is not necessary.
Figure 1. Blower Kit Installation
2 PELCO Manual C436M-B (12/94)