= Vertical bar in left or right margin indicates change or addition.
®
BK4000/BK4024/BK4220 Series
Blower Kit
Installation/Operation
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1.Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2.Unless the unit is specifically marked as a NEMA
Type 3-6P enclosure, it is designed for Indoor use
only and it must not be installed where exposed to
rain and moisture.
4.Only use replacement parts recommended by
PELCO.
Manual C436M-B (12/94)
2.0 SCOPE
The information contained within this manual covers
the installation and operation of the BK4000/BK4024/
BK4220 Blower Kits. Please familiarize yourself with
the information in this manual prior to installation and
operation.
2.1 DESCRIPTION
The BK4000/BK4024/BK4220 Blower Kits are engineered for installation in the EH4014 and EH4018 Enclosures. The BK4000 requires 120 VAC, the BK4024
requires 24 VAC, and the BK4220 requires 230 VAC.
All units can be used in conjunction with the corresponding Heater Kit.
BK4000 requires 4 watts at 120 VAC, 60 Hz.
BK4024 requires 3 watts at 24 VAC, 60 Hz. (CE)
BK4220 requires 4.8 watts at 230 VAC, 60Hz. (CE)
NOTE: Once installed, the blower kit will reduce
the maximum camera/lens length specified by 13/4 inches.
PELCO • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827 • DataFAX (800) 289-9108 or (1-559) 292-0435
3.0 INSTALLATION
The BK4000/BK4024/BK4220 Blower Kits are supplied with the following installation parts:
QTYITEM
1.Remove the Phillips Head screws from the rear cap
and slide the assembly out from the enclosure.
2.Attach the blower assembly to the rear plate using
two of the self-tapping screws, holding the end
cap to the sled.
1Blower
1Blower Bracket
To install the BK4000/BK4024/BK4220 perform the
following steps (refer to Figure 1):
51Insulator, PC board (heater kit only)BK400010000
A4Washer, nylonZH200X437X62N
B4Screw, 6-32 x 3/8 pan phil SSZH6-32X.375SPP
C2Screw, 6-32 x 1.5 pan phil SSZH6-32X1.50SPP
D2Nut, hex, 6-32ZH6-323NUTSH
E2Screw, 6-32 x 1/4 self tapping philZH6-SFX.250SPP
F8Internal tooth lockwasher, #6ZH6LWSIS
3.Wire according to the wiring diagram in Figure 2.
NOTE: When used with a heater kit (and
PCB), the blower can be wired into the terminal block on the PC Board (see Figure 2). With
the blower kit only, the PCB is not necessary.
Figure 1. Blower Kit Installation
2PELCO Manual C436M-B (12/94)
4.0 WIRING DIAGRAMS
The following items are supplied in the blower kits.
Refer to Figure 2 for wiring information with the use
of the heater kit PCB board, and without.
QuantityItemPELCO Part No.Blower Kit
1Fan, 120 VAC, 19 CFMMM750010003120 & 230 VAC models
1Fan, 24 VDC, 19 CFMED21000524 VAC model
1Resistor for fan, 3K ohmRES003.0K10.0230 VAC model
1Bridge Rectifier DiodeDIOMDA10424 VAC model
1CapacitorCAPU0050.0/2524 VAC model
1Component BracketBK7044002COMP24 & 230 VAC models
Thermostat
Heater/Blower wiring
diagrams using
Heater Kit with PCB.
Butt Splices Provided
Fan
1
2
3
4
5
6
7
8
9
10
120 V AC Model
Input, AC High
Input, AC (neutral)
Ground
Fan
Heater
1
2
3
4
5
6
7
Resistor
8
9
10
230 VAC Model
1
2
3
4
5
6
Diode
7
8
Bridge
9
10
24 VAC Model
Input, AC High
Input, AC (neutral)
Ground
Fan
Heater
Heater
+
Fan
_
Input, AC High
Input, AC (neutral)
Ground
Cap
Fan
Heater
Diode Bridge
AC
Cap
24 VAC (BK4024)
230 V AC (BK4220)
Blower Wiring
Installation only.
PCB not required.
120 VAC (BK4000)
Resistor
Fan
Figure 2. Blower Kit Wiring Diagram
PELCO Manual C436M-B (12/94)3
5.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
PELCO will repair or replace, without charge, any
merchandise proved defective in material or
workmanship for a period of one year after the date of
shipment (six months on all pan and tilts with auto scan
and medium duty scanners, and two years on Legacy®,
Intercept® and CM9500/CM8500 Matrix products).
PELCO will warranty all replacement parts and repairs
for 90 days from the date of shipment. All goods for
warranty work shall be sent freight prepaid to our
Clovis, California facility. Repairs made necessary by
reason of misuse, alteration, normal wear, or accident
are not covered under this warranty. PELCO is not
liable for any incidental or consequential expenses or
liability incurred by the customer as a result of field
repair, installation, or any other reason.
The above warranty is in lieu of any other expressed or
implied warranty, condition, or guarantee by PELCO
of the equipment listed herein. PELCO makes no
warranties except for intended use and will not be liable
for any loss, damage, or costs arising, whether
consequential or incidental, from the use of said
merchandise.
RETURNS
In order to expedite parts returned to the factory for
repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA
number if returned for repair). Goods returned for
repair or credit should be clearly identified with the
assigned CA/RA number and freight should be prepaid.
All merchandise returned for credit may be subject to
a 20% restocking and refurbishing charge.
Ship freight prepaid to:PELCO
300 West Pontiac Way
Clovis, CA 93612-5699
This warranty gives you specific legal rights. You may
also have additional rights, which are subject to variation
from state to state.
If a warranty repair is required, contact PELCO at
(800) 289-9100 or (559) 292-1981 for a
Repair Authorization number (RA), and provide the
following information:
1.Model and serial number
2.Date of shipment, P.O. number, Sales Order
number, or PELCO invoice number
3.Details of the defect or problem
If there is a dispute regarding the warranty of a product
which does not fall under the warranty conditions
stated above, please include a written explanation with
the product when returned.
Ship freight prepaid to:PELCO
300 West Pontiac Way
Clovis, CA 93612-5699
Method of return shipment shall be the same as method
by which the repair item is received by PELCO.
®
PELCO
300 West Pontiac Way, Clovis, CA 93612-5699
(559) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827 •
DataFAX (800) 289-9108 or (559) 292-0435
International customers call 1-559-292-1981 or
FAX 1-559-348-1120
(Product specifications subject to change
without notice.)
C436M-B
4PELCO Manual C436M-B (12/94)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.