Pelco BB5T User Manual

®
BB5A/BB5T Series
Back Box
Installation/
Operation Manual
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120

CONTENTS

Section Page
1.0 GENERAL .................................................................................................. 3
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3
1.2 REGULATORY NOTICES ..................................................................4
1.3 UNPACKING INSTRUCTIONS ..........................................................5
1.4 RECOMMENDED TOOLS ................................................................. 5
2.0 DESCRIPTION ..........................................................................................6
2.1 MODELS ............................................................................................ 6
2.2 CERTIFICATIONS ............................................................................. 6
3.0 INSTALLATION FOR IN-CEILING MODELS ............................................. 7
3.1 CEILING AND BACK BOX PREPARATION .......................................7
3.1.1 Hard Ceiling ...........................................................................7
3.1.2 Suspended Ceiling ................................................................. 8
3.2 WIRING ............................................................................................. 8
3.3 BACK BOX INSTALLATION ..............................................................12
3.4 BACK BOX CONNECTIONS ............................................................13
4.0 INSTALLATION FOR PENDANT MODELS .............................................. 15
4.1 PENDANT-MOUNT INSTALLATION ................................................. 15
4.2 SURFACE-MOUNT INSTALLATION .................................................15
5.0 TROUBLESHOOTING .............................................................................. 16
5.1 SERVICE MANUAL ..........................................................................16
6.0 SPECIFICATIONS .................................................................................... 17
7.0 WARRANTY AND RETURN INFORMATION ........................................... 20

LIST OF ILLUSTRATIONS

Figure Page
1 Back Box Parts ..................................................................................5
2 Compass Tool ....................................................................................7
3 Conduit Fitting Installation ................................................................. 7
4 Installing Back Box ............................................................................. 9
5 Fastening Back Box ........................................................................... 9
6Wiring Diagram for Spectra™ (Ver. 3.0) and Spectra II™ ................. 10
7Wiring Diagram for Spectra™ Lite .................................................... 10
8 Interconnect Door ............................................................................. 12
9Transformer Wiring ............................................................................13
10 Interconnect Circuit Board Electrical Connections for Spectra™
11 Interconnect Circuit Board for Spectra™ Lite ................................... 14
12 SD5 Series Dimension Drawing ........................................................ 18
(Ver. 3.0) and Spectra II™ ................................................................. 13

LIST OF TABLES

Table Page
AVideo Coaxial Cable Wiring Distances .............................................. 8
B 24 VAC Wiring Distances .................................................................. 11
REVISION HISTORY
Manual # Date Comments
C1488M 6/98 Original version. C1488M-A 9/98 Rev A. Revised the manual to incorporate Spectra™
C1448M-B 2/99 Rev B. Revised the input power ratings, certifications,
Lite material.
and operating temperatures. Revised model numbers for Spectra Lite™.
2 Pelco Manual C1488M-B (2/99)

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis­tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C1488M-B (2/99) 3

1.2 REGULATORY NOTICES

NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are de­signed to provide reasonable protection against harmful interference in a residen­tial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter­mined by turning the equipment off and on, the user is encouraged to try and cor­rect the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
4 Pelco Manual C1488M-B (2/99)

1.3 UNPACKING INSTRUCTIONS

Unpack and inspect all parts carefully.
Be sure to save the shipping box and any inserts. They are the safest material in which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its box and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replacement. (International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY AND RETURN section of this manual for instructions.
The following items are supplied:
IN-CEILING MODELS
1 Back box 1 Installation/Operation Manual (C1488M) 1 Parts bag (refer to Figure 1)
1 Conduit fitting 1 Safety chain bracket 1 Lock nut 1 Compass tool 4T-rail clip (clip, L-bracket, screw, lock washer, nut)
PENDANT MODELS
1 Back box 1Tube of pipe sealant 1 Installation/Operation Manual (C1488M)

1.4 RECOMMENDED TOOLS

Pelco does not supply basic tools needed for the installation process. The following tools are recommended:
Small flat screwdriver Coaxial cable stripper BNC crimp tool Wire stripper Wire cutter Pen or pencil (in-ceiling models only) Drill with 3/32-inch drill bit (in-ceiling models only) Saw to cut hole in ceiling (in-ceiling models only) Medium Phillips screwdriver (in-ceiling models and pendant surface-mount only) Drill with hole saw (pendant surface-mount only)
COMPASS TOOL
SAFETY BRACKET
CONDUIT FITTING & LOCK NUT
T-RAIL CLIP

Figure 1. Back Box Parts

Pelco Manual C1488M-B (2/99) 5

2.0 DESCRIPTION

The BB5A Series back boxes are used with the SD5 Series of Spectra™ (Software Version 3.0) domes and SD5A Series of Spectra II™ domes. The BB5T Series back boxes are used with the SD5T Series of Spectra™ Lite domes.
The BB5A-F and BB5T-F are for indoor installation in hard ceilings or standard 2-foot x 2-foot (61 x 61 cm) suspended ceilings.
The BB5A-PB (black), BB5A-PG (light gray), and BB5T-PG (light gray) pendant back boxes are for indoor installation. For outdoor use, the BB5A-PG-E and BB5T­PG-E include a heater and sun shield. The heater allows operation in temperatures down to -60°F (-51°C).

2.1 MODELS

BB5A-F Indoor back box for flush mounting in a ceiling
BB5A-PB Black pendant-mount back box
BB5A-PG Light gray pendant-mount back box
BB5A-PG-E Same as BB5A-PG except includes heater and sun shield
BB5T-F Indoor back box for flush mounting in a ceiling
BB5T-PG Light gray pendant-mount back box
BB5T-PG-E Same as BB5T-PG except includes heater and shield

2.2 CERTIFICATIONS

The products identified below have been tested and certified for agency compli­ance as noted.
Model CE FCC UL CSA/cUL
BB5A-F X X
BB5A-PB X X
BB5A-PG X X
BB5A-PG-E X X
BB5T-F X X
BB5T-PG X X
BB5T-PG-E XX
Applicable CE, FCC, UL, and CSA/cUL directives/standards:
93/68/EEC–CE Mark Directive 89/336/EEC, 92/31/EEC–Electromagnetic Compatibility (EMC) Directives
EN 55022: 1984 Class A–Radio-frequency emissions limits EN 50082-2: 1992–Immunity standard
IEC 801-2: 1984–ESD immunity IEC 801-3: 1984–Radiated field immunity IEC 801-4: 1988–Electrical Transients
FCC–47 CFR, Part 15, Subpart B, Class B
UL Listed (DRQH) E119552
cUL Listed (DRQH7)
Agency Compliance Certification
Additional applicable standards:
NEMA Type 4 (except -F flush mount models; NEMA Type 1)
•IP 66 (except -F flush mount models; NEMA Type 10)
6 Pelco Manual C1488M-B (2/99)
Loading...