Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
• Wood Stud Included
• Wood Beam Included
• Solid Concrete Included
• Cinder Block Included
• Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit - ACC215;
(Not evaluated by UL)
• Brick Contact Qualifi ed Professional (Not evaluated by UL)
• Other or unsure? Contact Qualifi ed Professional (Not evaluated by UL)
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• phillips screwdriver
• drill
• 5/16" (8mm) bit for concrete and cinder block wall
• 5/32" (4mm) bit for wood stud wall
• level
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Single Wood Stud Wall .....................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Attaching Adapter Plate to Flat Panel Display ........................................................................................................................6
Installing and Removing Flat Panel Display ...........................................................................................................................7
2 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-11 04-05-11
Before you begin, make sure all parts shown are included with your product.
Parts List
DescriptionQty Part #
hook bracket1095-1346095-4346095-1346095-4346
A
tilt assembly1095-0359095-0360095-0359095-0360
B
concrete anchor2590-0320590-0320590-0320590-0320
C
M4 x 10 mm phillips screw4504-9012504-9012504-9012504-9012
D
M4 x 20 mm phillips screw4504-9020504-9020504-9020504-9020
E
retaining spacer4590-5005590-5005590-5005590-5005
F
#14 x 2.5" wood screw25S1-015-C03 5S1-015-C03 5S1-015-C03 5S1-015-C03
G
M5 x 6 mm screw1520-1023520-1023520-1114520-1114
H
security driver1--560-1133560-1133
I
Parts may appear slightly different than illustrated.
ST630PST630P-S
ST630ST630-S
Part #Part #Part #
D
F
E
A
C
B
H
I
G
3 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-11 04-05-11
Installation to Single Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
1
Based on its edges, draw a vertical line down the stud’s center. Place tilt assembly (B) on wall as a template,
making sure that the two mounting holes are over the stud centerline. Level tilt assembly, and mark the center of
the two holes. Drill two 5/32" (4mm) dia. holes 2-1/2" (64mm) deep. Make sure that the tilt assembly is level, secure
it using two #14 x 2-1/2" wood screws (G) as shown.
Skip to step 2.
G
B
4 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-11 04-05-11
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
Make sure that tilt assembly (B) is level, use it as a
1
template to mark two mounting holes. Drill two 5/16"
(8mm) dia. holes to a minimum depth of 2-1/2"
(64mm). Insert anchors (C) in holes fl ush with wall
as shown (right). Place tilt assembly over anchors
and secure with two #14 x 2-1/2" screws (G). Level,
then tighten all fasteners.
WARNING
• Tighten screws so that wall plate is fi rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
fi nishing material. If mounting to concrete surfaces
covered with a fi nishing surface is unavoidable (not
evaluated by UL), the fi nishing surface must be
counter bored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16mm), custom fasteners must be supplied by
installer (not evaluated by UL).
1
Drill holes and insert anchors (C).
2
B
G
Place plate (B) over anchors (C) and secure with screws (G).
3
Tighten all fasteners.
SOLID CONCRETE
CINDER BLOCK
concrete
surface
C
C
INCORRECTCORRECT
wall
plate
plaster/
CUTAWAY VIEW
dry wall
concrete
wall
plate
plaster/
dry wall
concrete
5 of 23
G
B
ISSUED: 02-05-09 SHEET #: 201-9421-11 04-05-11
C
Attaching Adapter Plate to Flat Panel Display
WARNING
• If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly
secured, damage may occur to display or product may fail.
®
FOR VESA
2
Choose hole pattern as shown below. Attach hook
plate (A) to back of display using four M4 x 10mm
screws (D) as shown below.
*Note: If hole pattern is in a pocket, attach hook
plate (A) to back of display using four M4 x 20mm
screws (E) and four retaining spacers (F) as
indicated below.
75 MOUNTING PATTERN:
FOR VESA® 100 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach hook
plate (A) to back of display using four M4 x 10mm
screws (D) as shown below.
A
D
*For displays with
a hole pattern in a
pocket, spacers (F) go
between hook plate (A)
and display.
A
D
F
6 of 23
ISSUED: 02-05-09 SHEET #: 201-9421-11 04-05-11
Installing and Removing Flat Panel Display
Attach display to tilt assembly (B). Tighten
3
M5 x 6mm screw (H) to lock display to tilt assembly.
Note: For security models, use security driver (I) to
tighten M5 x 6mm screws (H).
To remove display from mount, loosen screw (H)
and lift display off of mount.
WARNING
• Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment
to safely handle placement of the display.
• Failure to lock hook plate (A) with screw (H) can
cause display to come off mount if hit accidentally.
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 20 in. • lb (2.26 N.M.) maximum torque.
Adjust tension knob on right side of mount shown in
4
fi gure 4.1 to desired tension to balance your display
size and weight.
Push or pull from top or bottom of display to adjust
tilt as shown in fi gure 4.1. The tilt can be adjusted to
a maximum of 15° forward or 5° backward.
DISPLAY
H
A
B
fi g. 3.1
CAUTION
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
• Be careful not to pinch fi ngers when pushing display
from the bottom.
TENSION KNOB
fi g. 4.1
7 of 23
All other brand and product names are trademarks or registered trademarks of their respective owners.