Peerless-AV PSTK-2955-W Installation [en, es, fr]

Installation and Assembly:
Tilt Wall Mount for 10" - 24" Flat Panel Displays
Models: PT630
Max UL Load Capacity: 80 lb (36.3 kg)
I
D
2
:
6
0
7
0
8
0
1
0
0
Features:
Display adapter plate simply hooks onto the wall plate for quick and easy installation
Adjustable up to 15° of forward tilt and up to -5° backward tilt
Tilt angle can be locked with simple tightening of mounting screws
Colors: Gloss Black
• Includes hardware for installation to wood studs, concrete, and cinder block
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerlessmounts.com
Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit - ACC215;
(not evaluated by UL)
Brick Contact Qualifi ed Professional (not evaluated by UL)
Other or unsure? Contact Qualifi ed Professional
Tools Needed for Assembly
stud fi nder ("edge to edge" stud fi nder is recommended)
phillips screwdriver
drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
level
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Single Wood Stud Wall .....................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Attaching Hook plate to Display with VESA 75 or 100 Mounting Pattern ...............................................................................6
Installing and Removing Flat Panel Display ...........................................................................................................................7
2 of 23
Before you begin, make sure all parts shown are included with your product.
A
r
Parts may appear slightly different than illustrated.
Parts List
Description Qty. Part #
wall plate 1 095-P1494 mounting plate 1 095-P1495
B
#14 x 2.5" wood screw 2 5S1-015-C03
C
concrete anchor 2 590-0320
D
M4 x 10 mm phillips screw 4 504-9012
E
M4 x 20 mm phillips screw 4 504-9020
F
retaining space
G
PT630
4 590-5005
A
B
C
D
EFG
3 of 23
Installation to Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
1
Based on its edges, draw a vertical line down the stud’s center. Place wall plate (A) on wall as a template, making sure that the two mounting holes are on the stud centerline. Level wall plate, and mark the center of the two holes. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the wall plate is level, secure it using two #14 x 2.5" wood screws (C) as shown.
Skip to step 2.
STUD
C
A
4 of 23
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard­ware and components.
Make sure that wall plate (A) is level, use it as a
1
template to mark two mounting holes. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (D) in holes fl ush with wall as shown. Place wall plate over anchors and secure with two #14 x 2.5" screws (C). Level, then tighten all fasteners.
1
Drill holes and insert anchors (D).
concrete surface
D
WARNING
• Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly to load-bearing concrete.
• Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).
INCORRECT CORRECT
wall
plate
concrete
wall
plate
concrete
2
A
C
Place plate (A) over anchors (D) and secure with screws (C).
3
Tighten all fasteners.
SOLID CONCRETE
D
A
D
CINDER BLOCK
CUTAWAY VIEW
plaster/ dry wall
plaster/ dry wall
5 of 23
C
Attaching Hook Bracket to Display with VESA 75 or 100 Mounting Pattern
WARNING
• If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to display or product may fail.
FOR VESA® 75 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach hook
2
bracket (B) to back of display using four M4 x 10 mm screws (E) as shown below.
*NOTE: If hole pattern is in a pocket, attach mounting plate (B) to back of display using four M4 x 20 mm screws (F) and four retaining spacers (G) as indicated below.
B
FOR VESA 100 MOUNTING PATTERN:
Choose hole pattern as shown below. Attach hook bracket (B) to back of display using four M4 x 10 mm screws (E) as shown below.
B
E
*For displays with a hole pattern in a pocket,
spacers (G) go between mounting plate (B) and display.
E
G
6 of 23
Installing and Removing Flat Panel Display
Position top slots of hook plate (B) onto phillips hex head screws on wall plate (A) as shown in fi gure 3.1.
3
NOTE: Sides of hook plate (B) must be outside of wall plate (A) on both sides as shown in fi gure 3.2. Guide slots of hook plate onto four phillips hex head screws as shown in fi gure 3.3.
Push or pull from top or bottom of display to adjust tilt as shown in fi gure 3.4. The tilt can be adjusted to a maximum of 15° forward or 5° backward. To lock the display into the desired tilt position, tighten phillips hex head screws on both sides of mount.
To remove display from mount, loosen screws one full turn and lift display off of mount.
WARNING
• Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment to safely handle placement of the display.
CAUTION
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 40 in. • lb (4.5 N.M.) maximum torque.
fi g. 3.1
DISPLAY
SLOT
PHILLIPS HEX HEAD SCREW
B
CAUTION
• Be careful not to pinch fi ngers when pushing display from the bottom.
fi g. 3.3
B
A
PHILLIPS HEX HEAD SCREWS
fi g. 3.4
fi g. 3.2
DISPLAY
WALL
TOP VIEW
A
SIDES OF HOOK PLATE (B) ON OUTSIDE OF WALL PLATE (A)
7 of 23
PHILLIPS HEX HEAD SCREWS
All other brand and product names are trademarks or registered trademarks of their respective owners.
© 2011, Peerless Industries, Inc. All rights reserved.
Peerless Industries, Inc.
2300 White Oak Circle
Aurora, Il 60502
www.peerlessmounts.com
Loading...
+ 16 hidden pages