ENG - This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is
included for wood stud, solid concrete and cinder block installation. Before installing make sure the supporting
surface will support the combined load of the equipment and hardware. Screws must be tightly secured. Do
not overtighten screws or damage can occur and product may fail. Never exceed the Maximum Load Capacity.
Always use an assistant or mechanical lifting equipment to safely lift and position equipment. Be careful not to
pinch fi ngers when operating the mount. For support please call customer care at 1-800-865-2112.
Tools Needed for Assembly.
ENG
ENG
Symbols
x3
Screws must get at least
ENG
ENG
WARNING
ENG
Do not overtighten screws.
#
ENG
Skip to step.
three full turns and fi t snug.
5/32"
(4mm)
5mm
(3/16")
5/16"
(8mm)
3/8"
(10mm)
To properly tighten screws: Tighten until screw
ENG
head makes contact, then tighten another 1/2
turn. Do not overtighten screws.
1
2
3
+1/2
4
2
2014-09-24 #:203-9450-1
ENG
Parts (Before beginning, make sure you have all parts shown below).
Parts List
A wall plate1201-T5946
B adapter bracket2200-T5946
C 4 mm allen wrench1560-1727
D concrete anchor4590-0320
E #14 x 2.5" wood screw4520-D1033
F M8 x 25mm4520-5027
G washer4540-D9406
H spacer4540-1059
ESF655P
Part #DescriptionQty
G
washer
(4)
H
spacer
(4)
A
wall plate
F
M8 x 25mm
1
(1)
(4)
(2)
B
adapter bracket
D
8mm concrete anchor
#14 x 2-1/2" wood screw
Wood stud wall.Concrete/Cinder block.
ENGENG
C
allen wrench
(4)
(4)
E
(1)
1a
1b
1a
WARNING
ENG - When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that
the wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
3
2014-09-24 #:203-9450-1
1a-1
ENG
Use stud fi nder to locate and
mark stud center lines.
1a-2
ENG
Level wallplate. Mark mounting holes on stud
center lines.
Level wallplate. Install using wood screws
provided.
ENG
Maximum 80 in. • lb (9 N.M.).
A
E (4)
2
5
2014-09-24 #:203-9450-1
1b
WARNING
ENG - When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum
compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks
must meet ASTM C-90 specifi cations and have a minimum nominal width of 8". Do not drill into mortar joints!
Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. It is
suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity. Never attach concrete expansion anchors to
concrete or cinder block covered with plaster, drywall or other fi nishing material.
Level wallplate. Install using concrete
anchors and wood screws provided.
ENG
Maximum 80 in. • lb (9 N.M.).
3/8"
A
E (4)
7
2014-09-24 #:203-9450-1
2
ENG
Center adaptor brackets vertically on back of screen.
3
x3
BB
X
X
B
B
G
H
F
ENG
Use of spacers is OPTIONAL.
8
2014-09-24 #:203-9450-1
4
5
6
ENG
Tighten.
9
2014-09-24 #:203-9450-1
ENG
This page intentionally left blank.
ESP
Página en blanco.
FRN
Cette page a été laissée en blanc intentionnellement.
Diese Seite wurde absichtlich freigelassen.
DEU
Deze pagina is met opzet blanco gelaten.
NEL
Pagina lasciata intenzionalmente vuota.
ITL
Tato strana je záměrně prázdná.
ČEŠ
Táto strana je zámerne prázdna.
SLK
Esta página foi intencionalmente deixada em branco.
POR
Bu sayfa özellikle boş bırakılmıştır.
TÜR
10
2014-09-24 #:203-9450-1
Peerless Industries, Inc. (“Peerless”) warrants to original end-users of Peerless® products will be free from defects in material and
LIMITED FIVE-YEAR WARRANTY
workmanship, under normal use, for a period of fi ve years from the date of purchase by the original end-user (but in no case longer than
six years after the date of the product's manufacture). At its option, Peerless will repair or replace, or refund the purchase price of, any
product which fails to conform with this warranty.
In no event shall the duration of any implied warranty of merchantability or fi tness for a particular purpose be longer than the
period of the applicable express warranty set forth above. Some states do not allow limitations on how long a implied warranty lasts,
so the above limitation may not apply to you.
This warranty does not cover damage caused by (a) service or repairs by the customer or a person who is not authorized for such service
or repairs by Peerless, (b) the failure to utilize proper packing when returning the product, (c) incorrect installation or the failure to follow
Peerless' instructions or warnings when installing, using or storing the product, or (d) misuse or accident, in transit or otherwise, including
in cases of third party actions and force majeure.
In no event shall Peerless be liable for incidental or consequential damages or damages arising from the theft of any product,
whether or not secured by a security device which may be included with the Peerless
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty is in lieu of all other warranties, expressed or implied, and is the sole remedy with respect to product defects. No dealer,
distributor, installer or other person is authorized to modify or extend this Limited Warranty or impose any obligation on Peerless in
connection with the sale of any Peerless
This warranty gives specifi c legal rights, and you may also have other rights which vary from state to state.
®
product.
®
product. Some states do not allow the
11
2014-09-24 #:203-9450-1
Peerless-AV
2300 White Oak Circle
Aurora, IL 60502
Email: tech@peerlessmounts.com
Ph: (800) 865-2112
Fax: (800) 359-6500