Peerless-AV ALU006009-AB, ALU009012-AW, ALU012018-AB, ALU012018-AW, ALU018024-AB Specsheet

...
Installation and Assembly:
Adjustable Extension Column 6" - 12'
Models:
ALU006009 (-AB) (-AW) ALU009012 (-AB) (-AW) ALU012018 (-AB) (-AW) ALU018024 (-AB) (-AW) ALU0203 (-AB) (-AW) ALU0305 (-AB) (-AW) ALU0406 (-AB) (-AW) ALU0507 (-AB) (-AW) ALU0608 (-AB) (-AW) ALU0810 (-AB) (-AW) ALU1012 (-AB) (-AW)
Max UL Load Capacity:
500 lbs (226.8 kg)
Note: The adjustable extension column
should only be used with Peerless UL Listed
products. The max load capacity for the
combined assembly is not to exceed the
lowest of all listed max load capacities.
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
• When installing or adjusting the ceiling mount, do not use adhesives, lubricants, or oils to prevent the screws from loosening. If you use adhesives, lubricants, or oils to prevent the screws from loosening, the casing may crack and the projector may fall, causing serious injury and damage to the projector.
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerlessmounts.com
ISSUED: 12-05-11 SHEET #: 154-9015-1
W
Before you begin, make sure all parts shown are included with your product.
Parts List
ABCD
adjuster tube
Model
ALU006009-AB 154-S1139 154-S1128 520-1706 560-9646 ALU009012-AB 154-S1139 154-S1137 520-1706 560-9646 ALU012018-AB 154-S1140 154-S1129 520-1706 560-9646 ALU018024-AB 154-S1140 154-S1130 520-1706 560-9646 ALU0203-AB 154-S1141 154-S1131 520-1706 560-9646 ALU0305-AB 154-S1142 154-S1132 520-1706 560-9646 ALU0406-AB 154-S1143 154-S1133 520-1706 560-9646 ALU0507-AB 154-S1143 154-S1138 520-1706 560-9646 ALU0608-AB 154-S1143 154-S1134 520-1706 560-9646 ALU0810-AB 154-S1143 154-S1135 520-1706 560-9646 ALU1012-AB 154-S1143 154-S1136 520-1706 560-9646 ALU006009-AW 154-S2139 154-S2128 520-2706 560-9646 ALU009012-AW 154-S2139 154-S2137 520-2706 560-9646 ALU012018-AW 154-S2140 154-S2129 520-2706 560-9646 ALU018024-AW 154-S2140 154-S2130 520-2706 560-9646 ALU0203-AW 154-S2141 154-S2131 520-2706 560-9646 ALU0305-AW 154-S2142 154-S2132 520-2706 560-9646 ALU0406-AW 154-S2143 154-S2133 520-2706 560-9646 ALU0507-AW 154-S2143 154-S2138 520-2706 560-9646 ALU0608-AW 154-S2143 154-S2134 520-2706 560-9646 ALU0810-AW 154-S2143 154-S2135 520-2706 560-9646 ALU1012-A
Quantity 1 Quantity 1 Quantity 2 Quantity 1
154-S2143 154-S2136 520-2706 560-9646
extension
pipe
M8 x 10 mm
screw
4 mm allen
wrench
Parts may appear slightly different than illustrated.
A
C
B
D
2 of 12
ISSUED: 10-26-11 SHEET NO: 154-9015-1
1
Note: Adjustable extension column should only be connected to UL Listed Peerless ceiling plates with 1 1/2"-11.5 NPT threading. See instruc­tions provided with ceiling plate for additional assistance.
Thread adjuster tube (A) into bottom of threaded fi tting on ceiling plate (sold separately) as shown in fi gure 1.1. Tighten adjuster tube so thread is securely engaged.
ceiling plate (sold separately)
fi g 1.1
1 1/2"-11.5 NPT threading
A
Align one small hole in the threaded fi tting of ceiling plate with slot of adjuster tube (A). Insert and tighten one M5 x 10 mm screw (not included) through the hole of threaded fi tting and slot of adjuster tube (A) as shown in fi gure 1.2.
WARNING
• Adjuster tube (A) must be fully threaded (six or seven full turns) onto threaded fi tting in ceiling plate and then locked with M5 x 10 mm screw.
2
Insert extension pipe (B) into adjuster tube (A) and secure with one screw (C). Adjust extension
pipe to locate screw (C) into desired hook slot as shown in fi gure 2.1.
Insert second screw (C) through hole opposite of hook slot as shown in fi gure 2.2. Tighten both screws (C) using allen wrench (D).
Note: Only UL Listed Peerless components with 1 1/2"-11.5 NPT threading should be connected to the adjustable extension column.
To connect additional component to adjustable extension column see instructions provided with your component.
M5 x 10mm screw (not included)
fi g 1.2
A
HOOK SLOTS
C
C
B
fi g 2.2
fi g 2.1
3 of 12
ISSUED: 10-26-11 SHEET NO: 154-9015-1
Recommended Cleaning Guidelines
The following procedures are not guaranteed to control infection. An infection control administrator or epidemiologist should be consulted regarding cleaning procedures and processes.
Most painted components will withstand cleaning by commonly used, diluted, non-abrasive solutions such as quaternary ammonia compounds, ammonia enzyme cleaners, and bleach or alcohol solutions. However, it is recommended that any surface be tested in an inconspicuous area prior to determine the propensity for discoloration.
• Pen or permanent and dry erase markers can be removed with 91% isopropyl alcohol and a soft cloth.
• Iodine stains can be removed with commonly used cleaners and a soft cloth.
• Never use steel wool or other abrasive materials that will damage the surface fi nish.
• Do not use Acetone, mineral spirits, abrasive cleansers, paint thinner or any other harsh or toxic chemicals to clean your product. These solvents will damage the surface fi nish.
WARNING
• To avoid risk of electric shock, do not expose electrical components to water, cleaning solutions or other potentially corrosive liquids or substances.
• Do not use fl ammable cleaners on product surfaces due to close proximity of electrical power and equipment.
Peerless Industries, Inc.
2300 White Oak Circle Aurora, Il 60502 www.peerlessmounts.com
4 of 12
All other brand and product names are trademarks or registered
ISSUED: 10-26-11 SHEET NO: 154-9015-1
© 2011, Peerless Industries, Inc. All rights reserved.
trademarks of their respective owners.