Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure
A
A
CAUTION:
CAUTION:
qualified service personnel.
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the
literature accompanying the product.
Risk of electrical shock - DO NOT OPEN!
To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to
WARNING:
appliance, read the operating guide for further warnings.
A
A
PRECAUCION:
PRECAUCION: Para
reparar. Deje todo mantenimiento a
ADVERTENCIA: Para
Antes de usar este aparato, lea
A
A
ATTENTION:
ATTENTION:
aucune piece pouvant
To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this
Este simbolo tiene el proposito de alertar al usuario de la presencia de
aislamiento dentro de la caja
corrientazo.
Este simbolo tiene el
y mantenimiento en la literatura que viene con el
Riesgo de corrientazo - No
Ce symbole est utilisepm indiquer a l’utilisateur la presence a
dangereuse pouvant
Ce symbole est utilise pour indiquer a l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions
I’utilisation
et l’entretien (service) de l’appareil dans la litterature accompagnant le produit.
Risques de
Afin de
etre reparee
proposito
disminuir el riesgo de corrientazo, no
evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato
etre d’intensite
choc
reduire
de1
product0 que puede tener una magnitud suficiente coma
de alertar al usario de la presencia de instruccones importantes sobre la operation
abra.
10s
tecnicos calificados.
m&s
advertencias en la guia de operation.
suffisante pour constituer un risque de
electrique - NE PAS OUVRIR!
le risque de
par l’utilisateur. Confier I’entretien a un personnel qualifie.
choc
electrique, ne pas enlever le couvercle. 11 ne se trouve a
producto.
abra
“(voltaje)
la cubierta. No hay piezas adentro que el usario pueda
l’interieur
de ce produit de tension non-isolee
choc electrique.
peligroso” que no tiene
para
constituir riesgo de
sur
I’interieur
AVERTISSEMENT:
ou a I’humidite.
Dieses Symbol
A
A
VORSICHT:
VORSICHT: Urn
keine Teile darin, die vom Anwender repariert werden konnten. Reparaturen nur von qualifiziertem Fachpersonal
durchfiihren
ACHTUNG: Urn
Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
von Ausreichender
Dieses Symbol
Handhabung und Wartung des Produkts betreffen.
Risiko - Elektrischer Schlag! Nicht
lassen.
Afin de prevenir
Avant d’utiliser cet appareil,
sol1
den Anwender vor unisolierten gefahrlichen Spannungen innerhalb des
Starke
sol1
den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam
das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden
einen elektrischen
sind,
Schlag
les
risques de
urn
einen elektrischen Schlag verursachen zu
oder Feuergefahr zu vermeiden,
decharge
lisez
offnen!
electrique ou de feu,
les
avertissements supplementairessitu& dans le guide.
2
sollte
n’exposez
konnen.
dieses
pas cet appareil a la pluie
Gehauses warnen,
machen,
Get-at nicht
dem Regen oder
die
die
sich
Congratulations on your purchase of the all new SupremeTMTransTube@
Series. This amp represents years
of research on vacuum tube emulation, resulting in a totally new Supreme. The preamp has been redesigned, using patent-applied for technology that redefines tubelike distortion and harmonic generation in
solid-state amps.
The new T. Dynamics circuitry, also awaiting several patents, creates the long sought for tube power compression phenomenon. This, in combination with resonance and presence circuitry, yields the closest tube
amp simulation to date. This compression effect is increased by turning the T. Dynamics control down, which
lowers the power level the amp puts out.
To further enhance the performance of the Supreme, an impedance-matching transformer is used to deliver
100
watts into 16, 8, or 4 ohms; and a footswitchable effects loop allows for even greater flexibility.
FRONT PANEL FEATURES
POWER SWITCH (1)
Depress the switch to the “on” position. The red LED will illuminate indicating power is being supplied to the
unit.
POWER LED (2)
Illuminates when AC power is being supplied to the amp.
T.
DYNAMICS CONTROL (3)
Adjusts the power level of the amplifier from 10% to 100% power. When set to lower settings, the power
compression simulation will be much more pronounced.
PRESENCE (4)
An active tone control that boosts the extreme high frequencies by 6
dB.
RESONANCE SWITCH (5)
Used to fine-tune the low frequency range of the speaker enclosure by varying the damping factor of the
amplifier between two presets.
EFFECTS LEVEL SWITCH (6)
Selects the effects loop operating level: -10 dBV (0.3 V RMS) when “out” and 0 dBV (1 V RMS) when “in.”
EFFECTS RETURN (7)
Input for returning signals from external low-level effects or signal processing equipment.
3
EFFECTS SEND (8)
Output for supplying signals to external low-level effects or signal processing equipment.
REVERB LEVEL (9)
Controls the overall reverb level.
POST GAIN (10)
Controls the overall volume level of the Lead channel. The final level adjustment should be made after the
desired sound has been achieved.
LOW, MID, & HIGH EQ (11,15)
Passive tone controls that regulate the low, mid, and high frequencies for the Lead and Clean channels,
respectively.
GAIN SWITCH (12)
Boosts the overall system gain. Depress to the “in” position to activate.
THRASH SWITCH (13)
Notches the mid range about 20
dB.
PRE GAIN (14)
Controls the input volume level of the Lead channel.
CHANNEL SELECT SWITCH (16)
Allows selection of the Lead or Clean channel. The “in” position of the switch selects the Lead channel and
the “out” position selects Clean.
NOTE: Channel selection may also be achieved by the remote footswitch. If remote selection is desired, the
channel switch must be in the “in” (Lead) position.
BRIGHT SWITCH (17)
Provides a preset boost (6
dB)
to treble frequencies. To activate, depress the switch to its “in” position.
VOLUME (18)
Controls the volume level of the Clean channel.
LOW GAIN INPUT (19)
Provided for instruments that have extremely high outputs, which can result in overdriving (distorting) the
High Gain input. If both inputs are used simultaneously, the output levels are the same (both are low gain).
HIGH GAIN INPUT (20)
Used for most electric guitars. It is 6 dB louder than the Low Gain input.
4
Back Panel:
BACK PANEL FEATURES
EXTERNAL SPEAKER JACKS (21)
Provided for connection of external speaker cabinet. Minimum external speaker impedance
is 8 ohms (4 ohm total impedance).
A
IMPEDANCE SELECTOR SWITCH (22)
Used to select the appropriate impedance of the speaker enclosure(s). If two enclosures of equal impedance
are used, the switch should be set at one half of that value (e.g., for two 16 ohm enclosures, set switch to
8 ohms; for two 8 ohm enclosures, set switch to 4 ohms).
PREAMP OUT (23)
The preamp out can be used to route the amplified signal to a mixing console, tape recorder, etc. Connect
the preamp output using a shielded cable to an input of the tape recorder, mixer, etc. This patch does not
affect the operation of the amplifier.
POWER AMP INPUT (24)
Used to connect line level signal to the power amplifier.
REMOTE SWITCH JACK (25)
Provided for the connection of the supplied remote footswitch. The footswitch is used to select the Lead or
Normal channels and defeat effects loop. When using remote footswitch, always insert the plug fully (second
click) to insure proper operation.
GROUND SWITCH (26)
Three position rocker-type switch, which, in most applications, should be operated in its center or zero
position. There may be some situations when audible hum and/or noise will come from the loudspeaker. If
this situation arises, position the ground switch to either positive or negative (+or -) or until the noise is
minimized.
NOTE: Should the noise problem continue, consult your Authorized Peavey Dealer, the Peavey Factory, or a
qualified service technician. THE GROUND SWITCH IS NOT FUNCTIONAL ON 220/240 VOLT MODELS.
LINE CORD (120 V PRODUCTS ONLY) (27)
For your safety, we have incorporated a three-wire line (mains) cable with proper grounding
facilities. It is not advisable to remove the ground pin under any circumstances. If it is neces-
A
sary to use the equipment without proper grounding facilities, suitable grounding adaptors
should be used. Less noise and greatly reduced shock hazard exists when the unit is operated with the proper grounded receptacles.
5
SPECIFICATIONS
Rated Power & Load:
Power specs measured with
T. Dynamics @ 10%
100 W RMS into 16, 8, or
4 ohms
Power @ Clipping: (typically)
(5% THD, 1
100
W RMS into 16, 8, or
kHz,
120 V AC line)
4 ohms
Frequency Response:
+O,
3
dB,
60 Hz to 20
kHz,
@80WRMS
Hum & Noise:
Greater than 86 dB below rated
power
Power Consumption:
Domestic: 300 W @ 60 Hz,
120 VAC
Export: 300 W @ 50/60 Hz,
220-230/240 V AC
PREAMP SECTION
The following specs are measured
I kHz with the controls preset as follows:
Push Bright, Off (out)
Channel Select Normal (out)
Low&
High @ 10
Mid 63 0
Presence @ 0 dB
Pre & Post Gain @ 10
Gain & Thrash, Off (out)
Normal Levels are with normal volume
625
Minimum Levels are with normal
volume @
IO
@
Preamp High Gain Input:
Impedance: High-Z, 1 M ohm
Nominal Input Level: -14
dBV,
200 mV RMS
Minimum Input Level: -24
dBV,
60 mV RMS
Maximum Input Level: 0
dBV,
1 VRMS
Preamp Low Gain Input:
Impedance: High-Z, 44 K ohms
Nominal Input Level: -8
dBV,
400 mV RMS
Minimum Input Level: -18
dBV,
120 mV RMS
Maximum Input Level: 6
dBV,
2VRMS
Effects Send:
Load Impedance: 1 K ohm or
greater
Nominal Output Level: -10
0.3 V RMS or 0
dBV,
dBV,
1 V RMS
if Effects Level is in
Effects Return:
Impedance: High-Z, 22 K ohms
Designed Input Level: -10
0.3 V RMS or 0
dBV,
dBV,
1 V RMS
if Effects Level is in
(Switching jack provides Effects Send to
Effects Return connection when not used)
Preamp Output:
Load Impedance: 1 K ohm or
greater
Nominal Output Level: 0
dBV,
1 VRMS
Power Amp Input:
Impedance: High-Z, 30 K ohms
Designed Input Level: 0
dBV,
1 VRMS
(Switching jack provides preamp output to
power amp input connection when not
used)
System Hum & Noise
@
Nominal Input Level:
(20
Hz to 20 kHz un weigh ted)
72 dB below rated power
Equalization:
Special low, mid, & high passive
type
EQ
Presence: +6 dB @ 5
Push Bright: +6 dB @ 2
Push Thrash: -20 dB notch
1
kHz
in Lead channel
kHz
kHz
@
Push Gain: Increases Lead gain
Push Resonance: +6 dB
@
cabinet resonance
External Footswitch Functions:
Lead Channel Defeat (when
selected with button)
Effects Loop Bypass
Dimensions & Weight:
10.25” H x 24.375” W x
11.25”
D
35.7 Ibs.
A
features and specl$cations listed herein are subject to change without notice.
Due to our
eforts
for constant improvements,
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.