Peavey PCX-U302 User Manual

P C
X
­U 3 0 2
P
C
X
-
U
3 0 2
PLL True
diversity
UHF wireless receiver
PLL True
diversity
UHF wireless receiver
OPERATING GUIDE
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable
parts inside. Refer servicing to qualified service personnel. WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain
or moisture. Before using this appliance, read the operating guide for further warnings.
Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para constituir riesgo de descarga eléctrica.
Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación y mantenimiento en la información que viene con el producto.
PRECAUCION: Riesgo de descarga eléctrica ¡NO ABRIR! PRECAUCION: Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No
hay piezas útiles dentro. Deje todo mantenimiento en manos del personal técnico cualifi­cado.
ADVERTENCIA: Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.
Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.
ATTENTION: Risques de choc électrique — NE PAS OUVRIR! ATTENTION:Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il
ne se trouve à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de l’appareil à un réparateur Peavey agréé.
AVERTISSEMENT: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements supplémentaires de ce manuel.
Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen inner­halb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elek­trischen Schlag verursachen zu können.
Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des
Produkts betreffen.
VORSICHT: Risiko — Elektrischer Schlag! Nicht öffnen! VORSICHT: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die
Abdeckung enfernen. Es befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal durchführen lassen.
ACHTUNG: Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
2
INTRODUCTION
Thank you for selecting a Peavey Pro Comm PCX­U302 quartz controlled single channel true diversity wireless microphone system. Before operating and installing this system please read this instruction manual carefully and thoroughly in order to attain the correct operating procedures and to achieve the best results.
True Diversity Receiver
The Peavey Pro Comm PCX-U302 quartz controlled receiver is a true diversity wireless system. This system is also equipped with “Superior frequency tracking and muting techniques” that is effective in eliminating the random noise interference when the receiver is in standby state. The Peavey Pro Comm PCX-U302 receiver is equipped with both balanced and unbalanced outputs.
This system includes the following accessories:
AC/DC Adapter
Mic Clip
Antenna (2)
Instruction Manual
1. UNIT FEATURES AND FUNCTIONS
A. Front Panel
Figure 1
1
2
7 8 109
354
3
6
1. Antenna Input Connector A
2. Power Switch and Indicator:
When the switch is turned on the red indicator
illuminates to denote normal power status.
3. Group Selector:
Selects a group of frequencies.
4. Channel Selector:
Selects a channel within a group. There are six
group numbers available. Groups one through four
each have six available channels (one through six).
Groups five through six each have three available
channels (one through three). All channels within the
same group are non-interfering when used in multiple
system installations (except group six).
5. Group Indicator:
Indicates the group selected.
6. Channel Indicator:
Indicates the channel selected.
7. RF Signal Level Indicator:
Indicates the RF signal strength received from the
microphone. As soon as the signal is emitted from
the microphone the LED indicator illuminates.
8. Audio Signal Level Indicator:
Indicates the audio signal level. As soon as the
microphone signal is modulated, the LED indicator
illuminates.
9. Volume Control:
Adjusts the AF output level of the receiver.
4
10. Antenna Input Connector B REAR PANEL
B. Rear Panel
11. DC 12V Input Jack:
Connect the 12V DC plug from the AC/DC adapter.
12. Balanced Audio Output Jack:
XLR type connector
13. Unbalanced Audio Output Jack:
1/4" Phone Jack
14. Unbalanced Level Switch:
“LOW” selection is for “Microphone-Level” output.
“HIGH” selection is for “Line-Out” level output.
15. Squelch Adjustment:
Adjust the squelch level to eliminate the RF noise
interference at the receiver.
2. INSTALLATION OF THE RECEIVER
1. Install one of the antennas at the antenna input connector A. Then install the other antenna at the antenna input connector B. Make sure both antennas are in the vertical position.
Figure 2
5
11
12 13 14 15
2. AC/DC Power Connection:
Fig. 3
Connect the AC/DC adapter cable to the DC 12V input jack. Then plug the adapter unit into an appropriate AC outlet as shown in figure 3. Caution: Make sure the correct voltage is present at the AC outlet as indicated on the AC/DC adapter.
3. AUDIO OUTPUT CONNECTION:
a. Unbalanced Level Switch Setting Position:
Make sure to match the unbalanced output setting to the device input setting. The incorrect setting could result in low sensitivity level or over load distortion. Ex. (If you are going into the “Line” input on a mixer or amplifier then the switch should be set to the high position. If you are going into the “Mic” input of an amplifier or mixer then the switch should be set to the low position.)
b. Unbalanced Output:
Connect the 1/4" phone plug of the audio cable into the unbalanced output connector on the back of the receiver. Connect the other end of the cable to the proper input of the
6
desired device. Make sure the unbalanced level switch is in the proper position before applying power.
c. Balanced Output:
Connect the male XLR connector into the balanced output connector on the back of the receiver. Connect the other end of the cable into the “Mic/Balanced” input of the desired device. The characteristics of the 3-pin XLR connector are shown below in figure 4.
Fig. 4
7
GND PIN 1
PIN 3
PIN 2
3. TWO 19/2-INCH UNITS RECEIVER INSTALLATION
A. Setup for single half-rack receiver
1. Push the rack mount brackets (RM-11)
upwards until it is firmly attached to the receiver. (Figure 5)
Fig. 5
B. SETUP FOR DUAL HALF-RACK RECEIVERS
1. Remove the screws at the top and bottom of the receiver where they will be joined together. Remove one steel plate from each receiver. Push the receivers next to each other. Refer to figure 6.
2. Insert the steel plate in between the two receivers (top and bottom). Align and fasten the screws tightly as shown in figure 6.
3. Align and fasten the rack mount brackets (RM-12) on the outer sides of both receivers as shown in figure 6.
8
Fig. 6
4. After completion, it can be rackmounted into an EIA standard rack case. Shown in figure 7.
5. Make sure that the system performs correctly by placing the system away from noise sources. Place the receiver at least one meter above the ground and one meter away from noise sources. Place the microphone at least one meter away from the receiving antenna, as shown in figure 8.
Fig. 7 Fig. 8
9
Loading...
+ 19 hidden pages