PCE Instruments PCE-A 430 Users guide

Page 1
© PCE Instruments
PCE-A 430 | Anemometer
User Manual
Last change: 3 May 2024
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Technical specifications ...................................................................... 2
3 Delivery scope ....................................................................................... 3
4 Device description ................................................................................ 3
4.1 Device .............................................................................................................................. 3
4.2 Screen ............................................................................................................................. 4
5 Operation ............................................................................................... 5
5.1 Power supply ................................................................................................................... 5
5.2 Switch on the meter.......................................................................................................... 5
5.3 Switch off the meter.......................................................................................................... 5
5.4 Automatic power off.......................................................................................................... 5
5.5 Backlight .......................................................................................................................... 5
5.6 Low battery ...................................................................................................................... 5
5.7 MAX/AVG function ........................................................................................................... 5
5.8 Temperature units ............................................................................................................ 5
5.9 Air velocity units ............................................................................................................... 5
5.10 Overrange or underrange ................................................................................................. 5
6 Contact ................................................................................................... 6
7 Disposal ................................................................................................. 6
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Technical specifications
Air velocity in m/s
Measurement range
0.7 m/s ... 30 m/s
Resolution
<20: 0.1 m/s / >20: 1 m/s
Accuracy
±(4 % +2 digits)
Air velocity in km/h
Measurement range
2.5 km/h ... 105 km/h
Resolution
<20: 0.1 km/h / >20: 1 km/h
Accuracy
±(4 % +2 digits)
Air velocity in mph
Measurement range
1.5 mph ... 67 mph
Resolution
<20: 0.1 mph / >20: 1 mph
Accuracy
±(4 % +2 digits)
Air velocity in knots
Measurement range
1.3 knots ... 58.3 knots
Resolution
<20: 0.1 knots / >20: 1 knot
Accuracy
±(4 % +2 digits)
Temperature in °C
Measurement range
-20 °C ... +50 °C
Resolution
0.1 °C
Accuracy
±1.5 °C
Temperature in °C
Measurement range
-4 °F ... +122 °F
Resolution
0.1 °F
Accuracy
±2.7 °F
General technical data
Measuring functions
MAX, average value
Units
m/s, km/h, kn, mph
Display type
LCD with backlight
Sensor
cup cross
Automatic power off
15 min
Menu language
English
Protection class (device)
IP20
Weight
36.5 g
Dimensions (L x W x H)
145 x 55 x 48 mm
Operating conditions
-20 ... 60 °C, 10 ... 90 % RH
Storage conditions
-20 ... 60 °C, 10 ... 75 % RH
Page 5
© PCE Instruments
3
3 Delivery scope
1 x PCE-A 430 anemometer 1 x 9V block battery 1 x device bag 1 x user manual
4 Device description
4.1 Device
1
Vane sensor
Display
ON/OFF key
MAX/AVG key
5
Thread for tripod mounting
Battery compartment
Page 6
© PCE Instruments
4
4.2 Screen
1
Display of the maximum value (MAX) / average value (AVG)
2
Beaufort scale
3
Air velocity unit
4
Air velocity reading
5
Temperature reading
6
Temperature unit
7
Battery level
Page 7
© PCE Instruments
5
5 Operation
5.1 Power supply
Open the battery compartment and insert a 9 V battery.
5.2 Switch on the meter
Press and hold the ON/OFF key for about 3 seconds until the LCD has switched on. You can then release the key.
5.3 Switch off the meter
Press and hold the ON/OFF key for about 3 seconds until the LCD has switched off. You can then release the key.
5.4 Automatic power off
The anemometer switches off automatically after about 15 minutes of inactivity.
5.5 Backlight
After starting the anemometer, press any key to activate the display backlight. The backlight switches off automatically after about 30 seconds of inactivity.
5.6 Low battery
If the low battery icon appears, replace the battery.
5.7 MAX/AVG function
Press the MAX/AVG key to display the maximum value on the screen. Press the MAX/AVG key again to display the average value on the screen.
5.8 Temperature units
You can display the temperature value in the units ºC and ºF. To change the unit, press and hold the MAX/AVG key for 3 seconds.
5.9 Air velocity units
You can display the air speed value in the units m/s, km/h, mph and kn (knots). To change the unit, briefly press the ON/OFF key.
5.10 Overrange or underrange Temperature
If the measured temperature value is below the measurement range, "OL" is displayed. If the measured temperature value is higher than the measurement range, "OH" is displayed.
Air velocity
If the measured air velocity value is above the measurement range, "OL" is displayed.
Page 8
© PCE Instruments
6
6 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
7 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 9
© PCE Instruments
7
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mula, 8 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...