Thank you for purchasing an Infrared Thermometer PCE-890U from PCE Instruments.
The Infrared Thermometer PCE-890U can provide fast, easy and accurate temperature readings. With
the non-contact (infrared) technology, they can be used to measure the surface temperature of hard-toreach objects like electrified equipment or moving objects, without any damage or pollution to them.
These units are widely used in Food preparation, Safety and Fire inspection, Plastic mouldings, Asphalt,
Marine, Printing ink and dryer temperature, Diesel and Fleet maintenance.
2 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
Do not store it in high temperature or humidity.
Do not disassemble the unit, repair it by qualified personnel
Do not immerse it in water.
Do not use volatile liquids to clean the unit, wipe it with dry soft cloth.
If the surface of the object under test is covered with frost, oil, grime, etc., clean it before taking
measurement.
Do not make measurement through transparent surface such as glass.
Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminium, etc.
Use extreme caution when the laser beam is turned on.
Do not point the beam toward anyone or any animals.
Do not allow the beam to strike the eye from a reflective surface.
Do not use the laser near explosive gases.
The device may only be used in approved temperature range.
The opening of the case should only be done by qualified personnel of the PCE Instruments.
The instrument should never be placed with the user interface (e.g. keyboard side on a table)
You should not make technical changes on the device
The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner
This user's handbook is published from PCE Instruments without any guarantee.
We expressly point to our general guarantee terms, they can be found in our general terms of business.
If you have any questions please contact PCE Instruments.
3
Page 4
3 Specification
Range
50 … 1150 °C / -58 … 2102 °F
Accuracy
-50 … 0 °C / -58 … 32 °F: ±4 °C
0 … 500 °C / 32 … 932 °F: 1.5% ±2 °C / 3.6 °F
Above 500 °C / 932 °F: 2% ±2 °C / 3.6 °F
Optical Resolution
50:1
Emissivity
Adjustable: 0.10 … 1.0
Resolution
0.1 °F (0.1 °F) >1000; 1 °C (1 °F) <1000
Response Time
<250 ms
Spectral Response
8 … 14um
Data recording
PC real-time monitoring and recording
Polarity Display
Auto display, "-" indicates negative, while positive
with no sign
Diode Laser
Output <1mW,630 … 670nm, class 2(II)
Automatic Power Off
Meter shuts off automatically after 20 seconds
Operating Temperature
0 … 50 °C (32 … 122 °F)
Storage Temperature
-20 … 60 °C (-4 … 140 °F)
Relative Humidity
Operating:10 … 95 % RH; Storage: <80 % RH
Power Supply
9V battery
Weight
290g
Dimensions (L x W x H)
191.5 x 126 x 60 mm
Manual
4
Page 5
4 System description
4.1 Meter description
1. LCD Display
2. Shift Up Button
3. Laser Pointer / Backlight
Button
4. Shift Down Button
5. Function Button
6. Tripod Nut
7. Battery cover
8. Trigger Button
9. Button to open the Battery
cover
10. IR Sensor
11. Laser Pointer
12. USB – Interface
Manual
5
Page 6
4.2 Display description
1. Data Hold Icon
2. Measurement Icon
3. Emissivity Icon
4. Laser Icon
5. Backlit Icon
6. Temperature
Unit(℃/℉)
7. Measurement
Readings
8. MAX/MIN/AVG/DIF
display area
9. DIF Icon
10. AVG Icon
11. High Alarm Value
12. Max/Min Icon
13. Low Battery Icon
14. Low Alarm Icon
15. High Alarm Icon
16. USB Connection Icon
17. Low Alarm Value
Manual
6
Page 7
Manual
5 Operating Instructions
5.1 Operating steps
Hold the meter by its handle grip and point it toward the surface to be measured. Pull and hold the Trigger
to turn the meter on, the "SCAN" icon will appear and begin testing. The surface temperature being tested
will be displayed on the LCD screen. Release the trigger, the "HOLD" icon will appear, and the reading
will be held for several seconds. The meter will automatically shut off after 20 seconds.
Note: If the meter used in an ambient temperature with wide temperature change, awaiting it at least 30
minutes to adjust it. The laser is designed for aiming only; it can be shut off while operating in short
distance to save the battery.
5.2 Button Function
1. °C/°F button: In Measurement Mode, press button “” and“”to switch the temperature unit
℃ or ℉.
Alarm readings. During measuring, press button“ ”until“”icon flashes on the screen, then
loose button“”enter into Emissivity Mode, press button“”and“”to adjust emissivity
value, then keep pressing button“” return to the normal measurement mode (After entering
Emissivity Mode, press button “” can set the High/Low alarm value ).
5.3 PC Software operating
5.3.1 Software installation
Insert the CD into the CD-drive, double-click the icon and follow the installation tips to install
software. After installed the software successfully, click the desktop shortcut icon to open the software,
see the software interface as below:
Connect the meter with PC via USB cable and power on the meter. The software will automatically
connect the meter and conduct real-time data transmission.
7
Page 8
Manual
5.4 Toolbar introduction;
5.4.1 File menu
Pull-down menu see as below:
1. Open: Open the saved data file
2. Save: Save data
3. Print: Printing charts
4. Exit: Exit the software
5.4.2 View menu
Pull-down menu see as below:
1. Zoom In: Zoom in the graph curve
2. Zoom Out: Zoom out the graph curve
3. Zoom CLS: Graph curve returns to the normal ratio
4. Y Grid: Y Grid of the graph
5. X Grid: X Grid of the graph
6. Cursor Cross: data the cursor points
7. Unit:°C/°F selection
5.4.3 Control menu
Pull-down menu see as below:
1. Start: Start recording
2. Stop: Stop recording
3. Connect: Connection establishment
4. Disconnect:Disconnect connection
8
Page 9
Save
Open file
Disconnect connection
Zoom in graph curve
Start recording
Connection establishment
Zoom out graph curve
Graph curve returns to the normal ratio
Graph curve background colour
Data curve colour
5.5 Short-cut icon explanation
Manual
5.6 Battery Replacement
When the low battery icon “” appears, replace the
meter's battery. Open the battery compartment, replace the
9V battery and close the battery compartment.
9
Page 10
Manual
6 Contact
If you have any questions about our range of products or measuring instruments please contact PCE
Instruments.
6.1 PCE Instruments UK
By post:
PCE Instruments UK Ltd.
Units 12/13 Southpoint Business Park
Ensign Way, Southampton
Hampshire
United Kingdom, SO31 4RF
By phone:
02380 987 035
6.2 PCE Americas
By post:
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
33458 FL
USA
By phone:
561 320 9162