PCE Instruments PCE-423N Users guide

Page 1
© PCE Instruments
PCE-423N Heat Wire Anemometer
User Manual
Last change: 13 December 2022
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
5 Switching the meter on and off ........................................................... 4
6 Measurement preparation .................................................................... 4
7 Measuring mode .................................................................................... 4
7.1 Main display ..................................................................................................................... 4
7.2 Average measurement (time-dependent) ......................................................................... 4
7.3 Average measurement (different points) ........................................................................... 5
8 Settings .................................................................................................. 5
8.1 Set unit ............................................................................................................................. 5
8.2 Flow rate setting ............................................................................................................... 5
8.3 Automatic power off.......................................................................................................... 6
8.4 View saved data ............................................................................................................... 6
8.5 Display brightness ............................................................................................................ 6
8.6 Date and time ................................................................................................................... 6
8.7 Calibration ........................................................................................................................ 7
9 Contact ................................................................................................... 7
10 Disposal ................................................................................................. 7
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
Do not touch the hot wire.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Velocity
Measurement range
0.00 ... 30.00 m/s
0.0 ... 5905.5 ft/min
Resolution
0.01 m/s
0.1 ft/min
Accuracy*
*the higher value applies
±0.10 m/s or ±5 % of rdg. at 0 ... 5 m/s ±0.30 m/s or ±5 % of rdg. at 5 ... 30 m/s ±19.6 ft/min or ±5 % of rdg. at 0 ... 984.2 ft/min ±59.0 ft/min or ±5 % of rdg. at 984.2 ... 5905.5 ft/min
Flow rate
Measurement range
0.0 ... 339120.0 m3 /h
0.0 ... 99598.0 CFM
Resolution
0.1 m3 /h
0.1 CFM
Temperature
Measurement range
0 ... 50 °C 32 ... 122 °F
Resolution
0.1 °C
0.1 °F
Accuracy*
±1 °C ±1.8 °F
Further specification
Telescopic probe length
210 ... 426 mm / 8.2 ... 16.7"
Telescopic probe diameter
12 mm / 0.47"
Memory space
10,000 measuring points
File format
CSV
Interface
micro USB
Bracket
3/8" tripod bracket
Display
2" LCD, 176 x 220 pixels
Measurement rate
1 Hz
Power supply (rechargeable battery)
internal rechargeable 1000 mAh battery Power supply (external)
5 V DC, 1 A
Operating conditions
0 ... 50 °C (32 ... 122 °F), <85 % RH, non-condensing
Storage conditions
-10 ... 60 °C (14 ... 140 °F), <85 % RH, non-condensing
Dimensions (without telescopic probe)
145 x 50 x 35 mm / 5.7 x 1.9 x 1.3" Weight
156 g / 0.34 lbs
3 Delivery scope
1 x hot wire anemometer PCE-423N 1 x micro USB cable 1 x user manual
Page 5
© PCE Instruments
3
4 Device description
No.
Meaning / function
1
flow sensor, temperature sensor
2
display
3
left function key
4
right function key
5
on / off key
6
Enter-V/F key, toggle key (velocity, flow rate)
7
back key
8
air slits
9
tripod bracket
10
micro USB connector
Page 6
© PCE Instruments
4
5 Switching the meter on and off
To switch the meter on or off, press and hold the key.
6 Measurement preparation
Before making a measurement, slide the probe guard down. Switch on the device. Point the opening of the sensor in the direction of the flow to be measured. When you have finished your measurement, push the guard back up so that the sensor system is not damaged.
7 Measuring mode
7.1 Main display
After the meter has been switched on, the velocity measurement is carried out immediately. At the same time, the current temperature is measured and displayed. To select between the velocity and the flow rate measurement, press and release the enter-V/F key once. The "V" on the display stands for velocity and the "F" for flow. The flow rate depends on the velocity and the set area. You can set the area under 8.2 Flow rate setting to set the area. Note: Saving individual measured values is not possible in normal measuring mode:
7.2 Average measurement (time-dependent)
To display the average, press the right function key in measuring mode to select . The display now shows for the average reading (time-dependent) and . Now press the left function key to select . The current velocity, the average, the highest and the
lowest measured value are displayed here. Press the left function key to save the displayed values . Press the right function key to start or
pause the current average measurement . To repeat the average measurement, go to normal measurement mode with the back key and start the average measurement again.
Page 7
© PCE Instruments
5
7.3 Average measurement (different points)
To determine the average of different measuring points, press the right function key in measuring mode.
Press the right function key again to select . To save the displayed values, now press the left function key . The values
are saved once per keystroke. To include the current measuring point in the average measurement and select the next one, press the right function
key . To repeat the average measurement, go back to normal measuring mode with the back key and start the average measurement again.
8 Settings
To make settings, press the left function key in measuring mode. Use the function keys to select between the individual functions displayed. At the same time, you can change selected parameters with the function keys. To open a setting, press the enter-V/F key. Press the back key to go back one level. Press the enter-V/F key to confirm your entry.
Setting
Meaning
Unit
Set the unit
Area / Funnel
Enter the dimensions for the flow rate
Auto-off
Set the automatic power off
History
Read memory
Brightness
Show brightness of the display
Date / Time
Set date and time
Calibration
Calibrate flow
8.1 Set unit
To set the unit for the flow and the temperature, go to the Settings menu and to the Unit menu item. Here, you can select between the temperature or the flow rate. Then you can change the unit.
Function
Units
Flow rate
m/s, m³/h / ft/min, CFM
Temperature
°C, °F
8.2 Flow rate setting
To specify the dimensions for the flow rate, go to the settings and select the menu item "Area/Funnel". Here, you can specify four different dimensions for square as well as round areas. In addition, a cylindrical area can be specified. The last selected area is adopted in measuring mode.
Page 8
© PCE Instruments
6
8.3 Automatic power off
Via the automatic power off function, the meter can be set to switch itself off after the set time. The following setting options are available here: "NONE" (function deactivated), 2 minutes, 10 minutes, 1 hour.
8.4 View saved data
To view the saved data, go to the settings and select the item "History". All saved measurement data can be viewed there. It is not possible to delete or edit the data on the meter itself.
Note: If no data has been saved, this item cannot be opened.
8.4.1 Transfer data to the computer
To transfer the measurement data to a computer, the meter must first be switched off. Now connect the meter to a computer which recognises it as a mass data storage device. The data can now be found in CSV data format.
8.5 Display brightness
To adjust the display brightness, go to the settings and open the item "Brightness". You can now use the function keys to adjust the brightness of the display.
8.6 Date and time
To set the date and time, go to the settings and open the menu item "Data/Time Setup". Here, the date and time can be set in the format YYYY/MM/DD. You can also choose between English and German style here. Use the function keys to change the parameters as desired. Use the enter-V/F key to accept the value and jump to the next item at the same time.
Page 9
© PCE Instruments
7
8.7 Calibration
To calibrate the flow rate, go to the "Calibration" item in the settings. Here, the displayed measured value can be set using a factor ("Gain"). The default value is 1.00. The coefficient range is between 0.5 and 2.
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 10
© PCE Instruments
8
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...