Paxton Vandal resistant metal keypad User Manual

Page 1
14/03/2011
Ins-30090 Vandal resistant metal keypad
Technical Support
01273 811011 support@paxton.co.uk
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Suitability
Paxton
Saturday from 09:00 - 13:00 (GMT)
Security-sensitive doors
Mounted on metal surface
Fitting for a water resistant installation.
Wet environments
Readers mounted together
The assembly is waterproof (IPX7 rated) when used with the mounting plate and all the cable connections are made inside the building.
Fitting to existing wiring
The alternative surface box contains a terminal strip making it ideal for connection to existing wiring.
Cable extensions
Keypads can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Page 2
Wiring
1 2 3
4 5 6
7 8 9
*
0
#
Connection to a control
unit reader port
When using this keypad with Net2, the software version used must be v3.21 or later.
WHITE labelled control units provide 5V at the Red terminal. The Red power wire for
the reader should therefore be directly connected to the 12V supply terminal.
Switch2 controllers with WHITE labels are incompatible with these products.
Connection modules
Reader junction box (325-020)
This module can be used to provide a connection point for the reader RJ45 plug. The terminals on the module are then wired colour for colour to the controller.
Alternatively, the reader can be wired directly into the screw terminals of the control unit by
rst cutting off the RJ45 plug and stripping
back the wires in the cable.
Reader port module (325-030)
This module may be purchased separately to speed up the installation and replacement of readers.
The reader port module is designed to convert the standard reader ports on Switch2 and Net2 controllers to accept one or two RJ45 connections. Pull off the screw terminal block from the reader port and simply replace it with this module.
Further information on how to purchase Installer Tools is available at:
http://paxton.info/841
Page 3
Technical Help
Here is the list of topics about this product that receive the most technical support enquiries.
We list them here to help you speed up the installation and trouble shooting process.
1 - Net2 - Bell function.
QPressing the bell button on the keypad will result in Relay 2 being energised for 1 second. A bell sounder can be Qcontrolled by wiring one of the bell feeds across COM / NO on the relay.
2 - Readers/keypads not working.
Q- Software settings - Conrm that the settings of the reader or keypad are correct. Q- Connections - Check the wiring of the connectors. Where possible, test this reader on the other port. Q- Extended Cable - Belden 9540 should be used. (100 m maximum) Twisted pair alarm cable should Q not be used. To conrm that an extended cable is not at fault, wire the reader direct into the reader port. Q- Supply voltage - Conrm that the voltage is within specication. (see table) Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader. Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall. Ensure Q that readers are not mounted back to back or there is no interference from other local RF devices.
3 - Readers/keypads - Extending cable.
QOnly Belden CR9538 / 9540 can be used for cable extensions. CR9538 8 core up to 25 m, CR9540 10 core for Q25-100 m (maximum extension). With CR9540, the two additional cores should be used to double up for power.
4 - Switch2 - Initialising with 2 keypads.
QEither Keypad can be used to initialise the controller. Connect all wires in parallel, colour for colour.
5 - Switch2 (White label) & Touchlock Switch Control (922-177).
QThis keypad style does NOT work with these control units.
6 - Duress Codes.
QNet2 - Duress codes cannot be programmed into Net2. QSwitch2 - These systems can accept Duress codes.
7 - Net2 - Replacing an old style keypad. (ACU Keypad port).
QWhen using this keypad with Net2, the software version used must be V3.21 or later and the keypad must be Qwired into the reader port.
Specications
Max
+55 °C
150 mA
Height
Outdoor Use
5 metres
600 µs
Yes
Depth
28 mm
40 mm
Environment
Operating temperatures - all items
Waterproof
Cable length
Electrical
Voltage
Current
Clock and data bit period
Backlight
Dimensions
With mounting plate
With surface mount box
Min
-20 °C
IPX7
8V DC 14V DC
Width
89 mm 143 mm
89 mm 143 mm
This product is not suitable for retail sale. All warranties are invalid if this product is not installed by a competent person.
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
Loading...