Paxton TOUCHLOCK compact stainless steel User Manual

TOUCHLOCK compact stainless steel
Ins-177 Date code: 250403
Contents
About .................................................................................................................................................. 3
Features ......................................................................................................................................................................... 3
Contents in box ............................................................................................................................................................ 3
For Stainless steel keypad kit ..................................................................................................................................... 3
Fitting ................................................................................................................................................. 4
Which release? .............................................................................................................................................................. 4
Fitting the electric release ........................................................................................................................................... 4
Wiring ................................................................................................................................................. 5
The white wires - Release output .............................................................................................................................. 5
The green wires - Bell output ..................................................................................................................................... 5
Backup power: .................................................................................................................................. 5
Commissioning................................................................................................................................. 6
Initialising the system ................................................................................................................................................. 6
What is the next step? .................................................................................................................................................. 6
Reset procedure ............................................................................................................................................................ 6
Operation ........................................................................................................................................... 7
Programming the keypad ........................................................................................................................................... 7
Single/multiple code mode ........................................................................................................................................ 7
Programming code ...................................................................................................................................................... 7
Normal, toggle and duress ......................................................................................................................................... 7
Silent operation ............................................................................................................................................................ 7
Lockout .......................................................................................................................................................................... 7
Data resetting the keypad ........................................................................................................................................... 7
Default Settings ............................................................................................................................................................ 7
Applications ...................................................................................................................................... 9
Standard Installation ................................................................................................................................................... 9
Duress alarm ................................................................................................................................................................. 9
Exit button .................................................................................................................................................................. 10
Time clock ................................................................................................................................................................... 10
Tech Help ......................................................................................................................................... 10
Specification .................................................................................................................................... 11
Ins-177 Date code: 250403
About
The output to the electric release is 12Vdc solid state limited to 500mA continuous and 750mA intermittent (7 seconds).
Features
The unit can be programmed with up to 50 user codes containing 4 - 8 digits each. An exit button may also be connected to the unit.
There are two outputs, one for the electric lock and one that can be used for a door bell/duress alarm see the TOUCHLOCK programming guide.
All system settings and the user codes are changed via the keypad.
Any number of TOUCHLOCK systems may be installed on a site.
Switch2 (Sales code 405-321/405-500) is an alternative product that has a separate keypad and control unit. Switch2 has two keypad capability for two way access control, voltage free relay contacts for the electric lock, and increased functionality. For more information contact our technical helpline.
Contents in box
For Stainless steel keypad
TOUCHLOCK keypad stainless steel Instructions for keypad Fitting kit for keypad
For Stainless steel keypad kit
TOUCHLOCK keypad stainless steel Instructions for keypad Fitting kit for keypad kit 12V 1Amp AC transformer 12V DC fail locked release kit Mortice fitting for release Rim fitting for release
About Page 3 of 11
Fitting
Using the template provided, mark and drill holes for the cable and the two screws. Enlarge the upper part of the cable hole as shown in the diagram below:
Tap in the wall plugs and screw the top No.8 x
1” posi pan to the wall. Leave the head of the screw about 2mm from the face of the wall.
Thread the cable through the wall.
Locate the screw into its keyhole on the back of
the keypad and slide the keypad down to engage. Remove and adjust as necessary.
Tighten down with the bottom No.8 x 1” screw.
Which release?
The TOUCHLOCK compact can be used with 12V DC fail open or fail closed releases. Ensure that the release consumes no more than 500mA for continuous use from 12V, or 750mA for intermittent use (7 secs). Please refer to manufacturer’s instructions for detail on specific releases.
The TOUCHLOCK compact keypad uses a small residual current to detect the presence of an electric release, used for the data reset procedure. For this reason TOUCHLOCK compact must not be connected directly to a relay coil.
Keypad
No8x1"
Wallplugs
Cable
Fitting the electric release
Decide on a suitable position for the electric release on the door frame.
Remove the cover of the release.
Using the 3.5mm cable clips provided, tack the white cable from the TOUCHLOCK to the release and
connect the two wires to the terminals on the release. Polarity does not matter when using a standard 12V DC release.
Replace the cover of the release.
If using the rim fitting, do not refit the side plate, this is not used.
Screw the release to the door frame using the No.8 x 1” screws
provided.
Door
frame
Cover
screws
Rim
Mortice
No. 8X1"
screws
Release
Release
Door
Door
Fitting Page 4 of 11